Scanner Features and Presentation Mode

Scanner Features and Presentation Mode

  1. LED
  2. Scan Window
  3. Scan Trigger

Aiming - Right/Wrong

Aiming - Right/Wrong

Scanning

Hand-Held
Scanning - Hand-Held

Hands-Free (Presentation)
Scanning - Hands-Free (Presentation)

Connect Host Interface

warningNOTE: Cables may vary depending on configuration.

USB

Connect Host Interface
Scan ONE of the bar codes below. The digital scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, scan another host bar code below.


*USB Keyboard HID


IBM Hand-Held USB


IBM OPOS (IBM Hand-Held USB with Full Scan Disable)


Symbol Native API (SNAPI) with Imaging Interface

RS-232

RS-232
Scan ONE of the bar codes below. The digital scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, scan another host bar code below.


*Standard RS-232


ICL RS-232


Wincor-Nixdorf RS-232 Mode A


Wincor-Nixdorf RS-232 Mode B


OPOS/JPOS


Fujitsu RS-232

Keyboard Wedge

Keyboard Wedge
Scan ONE of the bar codes below. The digital scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, scan the IBM PC/AT and IBM PC COMPATIBLE bar code below.


IBM PC/AT & IBM PC Compatibles


*IBM AT Notebook

IBM 46XX

IBM 46XX
Scan ONE of the bar codes below. The digital scanner automatically detects the host interface type, but there is no default setting. Scan one of the bar codes below to select the appropriate port.


Hand-Held Scanner Emulation (Port 9B)


Non-IBM Scanner Emulation (Port 5B)


Table-Top Scanner Emulation (Port 17)

Useful Bar Codes

Set Defaults


Set Factory Defaults

Add a Tab Key


Tab Key

Add an Enter Key

Add Enter Key (Carriage Return/Line Feed)

USB Caps Lock Override


Override Caps Lock Key (Enable)

User Indications (By Default)

Tab 1

Indication Beeper Sequence
Power up Low/medium/high beep
Bar code is successfully decoded Short high beep
Transmission error 4 long low beeps
Successful parameter setting High/low/high/low beep
Correct programming sequence performed High/low beep
Incorrect programming sequence, or Cancel Low/high beep

Tab 2

Indication LED Indicator
Hand-Held Scanning
Scanner is on and ready to scan, or no power to Off
Bar code is successfully decoded Green
Transmission error Red
Hands-Free (Presentation) Scanning
No power to scanner Off
Scanner is ready to scan Green
Bar code is successfully decoded Off momentarily
Transmission error Red

123Scan

123Scan is an easy-to-use, PC-based software tool that enables rapid and easy customized setup of a scanner via a bar code or USB cable. For more information, visit: http://www.zebra.com/123Scan.

Utility Functionality

  • Device configuration
  • Electronic programming (USB cable)
  • Programming bar code(s)
  • Data view - scan log (display scanned bar code data)
  • Access asset tracking information
  • Upgrade firmware and view release notes
  • Remote management (SMS package generation).

Troubleshooting

Aiming line does not appear

No power to scanner Connect scanner to powered host, or connect power supply
Aiming line is disabled Enable aiming line

Scanner decodes bar code but does not transmit data

Interface cable is loose Reconnect the cable
Transmission or format error Set the proper communication and conversion parameters
Invalid ADF rule Program the correct ADF rules

Scanner does not decode bar code

Scanner not programmed for bar code type Enable that bar code type
Bar code is unreadable Ensure the bar code is not defaced; scan a test bar code of the same bar code type
Bar code is out of aiming line area Move the aiming line over the bar code

Scanned data incorrectly displayed on host

Host interface not configured properly Scan appropriate host parameter bar codes
Region improperly configured Select appropriate country and language encoding scheme

RECOMMENDED USAGE GUIDE - OPTIMUM BODY POSTURE

LED Devices

Classified as 'EXEMPT RISK GROUP' according to IEC 62471:2006 and EN 62471:2008. Pulse duration: 9 ms.

Power Supply

Use ONLY a Zebra approved UL LISTED ITE (IEC/EN 60950-1, LPS/SELV) power supply with electrical ratings: Output 5.2Vdc, min 1.1A, with a maximum ambient temperature of at least 50 degrees C. Use of alternative power supply will invalidate any approvals given to this unit and may be dangerous.

Service Information

If you have a problem using the equipment, contact your facility's Technical or Systems Support.
If there is a problem with the equipment, they will contact the Zebra Global Customer Support Center at: http://www.zebra.com/support.
For the latest version of this guide go to: http://www.zebra.com/support.

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Zebra DS2208 - DS2200 Series Digital Scanner Quick Start Manual

Advertisement

Need Assistance?

Do you have a question about the DS2208 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents