Sears Kenmore W10435038B Instruction Manual page 20

Plastic tub undercounter dishwasher
Table of Contents

Advertisement

Available languages

Available languages

°
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire—Connect
ground wire
Form bare ground wire into a U-shaped hook. Wrap ground
wire hook clockwise around ground connector screw and under
the washer. Securely tighten ground connector.
Direct Wire—Connect
remaining wires
KO
\ \
/
= Se
NOTE: Do not pre-twist stranded wire. Twist on UL listed/CSA
approved wire connector. Gently tug on wires to be sure both
are secured.
20
Connect wires black to black and white to white, using UL
Listed /CSA Approved twist-on wire connectors (not included).
Wiring configuration
Terminal box-wire:
white
<->
white
black «—_—
black
ground wire «<<»
ground connector
Power supply wire:
4 | Direct Wire—Secure cable
in strain relief
Tighten strain relief screws to secure cable.
Direct Wire—Reinstall
terminal box cover
Place wires inside terminal box. Insert tabs on left side of cover.
Make sure wires are tucked inside box. Close cover ensuring
wires are not pinched. Use 1" nut driver or Torx® T20°
screwdriver and previously removed screw to secure cover.