Sollatek Voltshield AVS30 Manual

Automatic voltage switcher
Hide thumbs Also See for Voltshield AVS30:

Advertisement

Quick Links

SAFETY
All equipment designed and manufactured by Sollatek (UK) Ltd
complies with the latest safety codes of practice. You should still
follow all safety instructions and use caution when installing and
operating electrical equipment.
To avoid the risk of a shock, DO NOT expose this equipment to rain,
moisture, or liquid spillage. Before attempting to use it, ensure that
the total loading of your equipment does not exceed 30 Amps.
START-UP
When the AVS30 is powered up, it will enter Wait Mode and your
WAIT
equipment will remain OFF.
After the wait time has elapsed or the "By-pass Wait" button is
ON
pressed, the AVS30 connects the supply to turn your equipment ON.
OPERATION
High Voltage. Equipment OFF
OFF
Good Voltage, recovered from high voltage. AVS30 in Wait Mode,
WAIT
equipment OFF
Good Voltage. Equipment ON
ON
Good Voltage, recovered from low voltage. AVS30 in Wait Mode,
WAIT
equipment OFF
Low Voltage. Equipment OFF
OFF
WAIT MODE
Wait Mode provides voltage monitoring and protection against power-back surges
and frequent power-ups by ensuring the mains power has fully stabilised before
reconnecting it to your equipment. If:
a) Wait Mode set to a time: The AVS30 reconnects power to
your equipment automatically after the set wait time has
elapsed.
b) Wait Mode set to Man: The AVS30 will remain in wait mode
until the power is manually connected to the equipment via
the BY-PASS WAIT button.
Note: If wait mode is set to a time, the delay can be bypassed to instantly turn your
equipment ON by pressing the BY-PASS WAIT button on the front of AVS30.
The AVS30 will automatically adjust the wait time depending on the disconnection
period to make the total OFF time equal to the set Wait Time. i.e. If Wait Time is 3
minutes and the disconnection is 2 minutes, then the wait time added is just 1 minute.
TIMESAVE™
When the AVS output remains switched off for more than the user set Wait Time, on
resumption of a stable supply, the AVS output will automatically switch back on and
supply load after 10 seconds.
LIABILITY OF THE COMPANY
a) The company shall not be liable, either in contract or in tort for any loss, injury or
damage of whatsoever nature or to whomsoever or by whatsoever cause arising
directly or indirectly from any defect in the Goods (whether latent or apparent) or
as a result of the use of the Goods (save and except any liability for death of or
injury to any person resulting directly from the negligence of the company) and the
customer shall fully indemnify the company against all claims and demands made
RISK OF
upon the company by reason of any such loss or injury or damage.
ELECTRIC SHOCK
b) Without prejudice to the provisions of the immediately preceding sub clause
the company shall not in any event be liable for consequential or indirect loss or
damage howsoever arising under the contract or in relation to the Goods.
c) The customer hereby acknowledges that the restrictions in this clause are fair and
reasonable in the circumstances.
WARRANTY
Unless otherwise agreed with the company or where the company has notified the
customer of special terms in respect of specified categories of goods the company
agrees at its option either to refund the cost of or repair or replace goods proved to
the company's reasonable satisfaction to have failed under proper storage and use
within 24 months of delivery by reason of defects due to faulty design (other than
any design made, furnished or specified by the customer) materials or workmanship
provided that:
a) The customer shall have followed any instruction issued by the company in relation
to the goods and their storage.
b) In the case of defects which would have been apparent to the customer on
reasonable examination of the goods on delivery, 'the' customer shall notify the
company of the defects within 14 days of delivery.
c) In the case of any other defects the customer shall notify the company of the
defects in writing within 7 working days of the date when the defect becomes
apparent.
d) Where in discharge of its obligation under this clause the company agrees that
the customer may undertake any repair work on its behalf the cost of such work
shall be agreed in writing between the customer and the company before the
commencement of such work.
RETURN OF GOODS
BY-PASS
WAIT
a) Goods supplied in accordance with the customer's orders cannot be accepted for
return without the prior written consent of the company and in accordance with the
company's returns procedure.
b) The company reserves the right to levy a handling, administration or other charge
of such amount as it, in its absolute discretion, decides and may deduct this from
any credit allowed unless the reason for any return by the customer is due to any
fault or breach of these conditions on the part of the company.
c) Returned goods must be sent carriage paid at the customer's risk to the company's
trading premises or to such other address as the company may direct.
d) The company will not allow credit in respect of returned goods not in fully re-
saleable condition.
AVS30 User Manual Jan 2024 v1
MJA
29/01/2024
A/I: 10911004
S/C: 74108410
Voltshield
Voltright
TM
TM
AVS30
The Switcher Range
The Stabiliser and Regulator Range
Voltsafe
Voltsure
APPLIANCE GUARD
TM
TM
The Suppressor Range
The UPS Range
AUTOMATIC VOLTAGE SWITCHER

Advertisement

loading
Need help?

Need help?

Do you have a question about the Voltshield AVS30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sollatek Voltshield AVS30

  • Page 1 SAFETY a) The company shall not be liable, either in contract or in tort for any loss, injury or All equipment designed and manufactured by Sollatek (UK) Ltd damage of whatsoever nature or to whomsoever or by whatsoever cause arising complies with the latest safety codes of practice.
  • Page 2 TERMINAL COMPARTMENT MOUNTING ELECTRICAL CONNECTIONS REPAIR/MAINTENANCE SETTING CHANGE Within the Terminal compartment, there 1) Mark and drill the top mounting • A fuse or circuit breaker (30 Amps If the AVS30 is subject to a severe surge, Setting Change Change Fuse Dial Range Default...