Ultrawater
Operations & Maintenance
Manual
REV 3/2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultrawater and is the answer not in the manual?

Questions and answers

Summary of Contents for lanry Ultrawater

  • Page 1 Ultrawater Operations & Maintenance Manual REV 3/2021...
  • Page 2: Table Of Contents

    3.3 Display Resolution 12-13 3.4 Volume Display Options 3.5 Communication Output Modes 3.6 Pulse Output(Open Drain) 3.7 4-20mA Output(Analog Output) 16-17 3.8 Modbus(M-bus) Output 3.9 Mdbus-RTU Communication Protocol 19-23 3.10 Output Module Installation (Optional) 24-29 - 2 - Lanry Instruments www.lanry-flow.com...
  • Page 3: 1、 General Information Page

    General Information 1.1 Introduction Thank you very much for choosing Lanry ultrasonic water meter. This ultrasonic water meter adopts dynamic zero point and time calibration before each measurement, which makes flow measurement more stable and accurate. Ultra-low power design, service life of up to 15 years; the...
  • Page 4: Unpacking Instructions

    Standard of the People's Republic of China GB/T 778-2018 <<Drinking Water Meter and Hot Water Meter>> ⚫ The ex-factory verification is based on the National Metrological Verification Regulation of the People's Republic of China JJG162-2009 <<Cold Water Meter >>standard. - 4 - Lanry Instruments www.lanry-flow.com...
  • Page 5: Measurement Method

    These two times are used to calculate the flow velocity. The Ultrawater ultrasonic flow meter is a battery-powered, precision flow meter designed for linear, bidirectional flow measurement of water.
  • Page 6: Technical Data

    GPM, L/s,m/s or M3/h for rate of flow Power Source 2XD Size Lithium Thionyl Chloride Batteries-15 Year Warranted life Time Output Modbus M-bus Pulse 4-20mA Data Storage Automatic storage of data for 10 years - 6 - Lanry Instruments www.lanry-flow.com...
  • Page 7: Flow Range

    1.280 0.08 0.08 0.125 0.200 0.500 0.800 Qmin 0.05 0.05 0.08 0.25 Q3/Q1 Note: The ultrasonic water meter of each diameter of the factory, the calibration data is subject to the actual calibration certificate. - 7 - Lanry Instruments www.lanry-flow.com...
  • Page 8: Mechanical Data

    332mm 383mm 456mm 4” h-Height 1 1/2” 3 1/2” 3 1/2” 5 1/2” 6 1/2” 8” 9 1/2” 40mm 90mm 90mm 103mm 140mm 165mm 203mm 245mm Weight 11kg 13kg 15kg 32kg 45kg 68kg 96kg - 8 - Lanry Instruments www.lanry-flow.com...
  • Page 9: Error Curve

    Technical Data 2.5 Error Curve - 9 - Lanry Instruments www.lanry-flow.com...
  • Page 10: 3、 Display & Output Model

    Display & Output Model 3.1 Display (LCD) - 10 - Lanry Instruments www.lanry-flow.com...
  • Page 11: Display Description

    Display & Output Model 3.2 Display description Ultrawater Ultrasonic water meter with Multi-line 9 digit Liquid Crystal Display (LCD),The display of each part is as follows: ⚫ Flow Direction:The upper arrow flows in the positive direction, while the lower arrow flows in the reverse direction.
  • Page 12: Display Resolution

    Display & Output Model 3.3 Display Resolution Default Display - (lowest resolution = 0.001 unit) Optional Display - (lowest resolution = 0.01 unit) - 12 - Lanry Instruments www.lanry-flow.com...
  • Page 13 Display & Output Model 3.3 Display Resolution Optional Display - (lowest resolution = 0.1 unit) Optional Display - (lowest resolution = 1 unit) - 13 - Lanry Instruments www.lanry-flow.com...
  • Page 14: Volume Display Options

    Volume Units of cumulative traffic can be changed by Modbus. Communication Output Modes Ultrawater ultrasonic water meter has three output modes. The three output modes are integrated into a communication module. The three output modes are all passive output through connecting wires. It needs external 8-24V AC/DC power supply.
  • Page 15: Pulse Output(Open Drain

    MODBUS command, and set pulse output equivalent at the same time. Refer to Modbus communication for specific settings. 2、When 8-24v AC or DC is connected, the pulse output does not need external 24V DC and pull-up resistance. - 15 - Lanry Instruments www.lanry-flow.com...
  • Page 16: 4-20Ma Output(Analog Output

    20 mA is factory programmable according to the customer’s requirements. (If the customer has not specified the 20 mA at the time of order, the Ultrawater will be programmed with the 20 mA at the max flow of the meter.)
  • Page 17 Refer to Modbus communication for specific settings. 2、Different current loop output forms are required. Please inform us when ordering. The factory default is two-wire output. Note: the analog output function has been cancelled! - 17 - Lanry Instruments www.lanry-flow.com...
  • Page 18: Modbus(M-Bus) Output

    Communications Factory default baud rate 9600, no check, 8-bit data, 1 stop bit. RS485 Module Wire Color Function Yellow RS485 A M-bus BS1 Output cable Blue RS485 B M-bus BS2 White Warning: Signal connection polarity is mandatory - 18 - Lanry Instruments www.lanry-flow.com...
  • Page 19: Mdbus-Rtu Communication Protocol

    Device Address – Echo of device address sent in master message to the device Function code – Echo of function code sent in master message to the device Data payload – 0-N bytes with response from device. CRC – 2 bytes with a value computed mathematically - 19 - Lanry Instruments www.lanry-flow.com...
  • Page 20 2 to 64 Data Payload N byte 2 bytes Response Address 1 byte 1-255 Function Code 1 byte Byte Count 1 byte 0 to 62 Data Payload N bytes 2 to 64 2 bytes - 20 - Lanry Instruments www.lanry-flow.com...
  • Page 21 Set special date in BCD format Read/Write uint Display control Read/Write uint Rs485 control Read/Write uint User control Read/Write uint RS485 Retention time Read/Write float Battery level Read/Write float Software version Read only float Pipe lose parameter - 21 - Lanry Instruments www.lanry-flow.com...
  • Page 22 ⚫ Bit 8: Display test, automatically restore after all lighting for 1 s ⚫ Bit [10-9]: Cumulative unit selection 00:m3 01: ft3 10:gal 11: A.F. ⚫ Bit [12-11]: Instantaneous flow unit selection 00:m3/h 01:l/s 10: gal/min - 22 - Lanry Instruments www.lanry-flow.com...
  • Page 23 ⚫ Bit [4-2]: Pulse output resolution selection 000:2ml 001: 100ml 010:1L 011:10L 100:100L 101:1m3 110:10m3 111:100m3 ⚫ Bit 5: Pulse Output Enable ⚫ Bit 12: Positive Accumulation Enable ⚫ Bit 13: Negative Accumulation Enable ⚫ Bit 14: Zero Calibration Enable - 23 - Lanry Instruments www.lanry-flow.com...
  • Page 24: Output Module Installation (Optional)

    Ultrawater wate to prevent damage to the communication port. Installing an Ultrawater without a cover plate or communication module would void any warranty.
  • Page 25 Step 1: Remove the Sealing Cap from the cover plate(Pic.2) . Pic.2 Step 2: Using the 3mm Allen Key provided, remove the cover plate (Pic. 3). Keep the cover plate and 3mm x 15mm screws for future use. Pic.3 - 25 - Lanry Instruments www.lanry-flow.com...
  • Page 26 Display & Output Model Step3: Please rotate the blue protective cap counterclockwise(Pic. 4), The communication port is now exposed. (Pic. 5) Pic.4 Pic.5 - 26 - Lanry Instruments www.lanry-flow.com...
  • Page 27 After inserting, tighten the plug of the output connecting line to ensure that the plug and the socket are well connected (Pic. 7.8.9) Pic.6 - 27 - Lanry Instruments www.lanry-flow.com...
  • Page 28 Display & Output Model Pic.7 Pic.8 - 28 - Lanry Instruments www.lanry-flow.com...
  • Page 29 If the module is going to be removed for an extended period of time, reinstall the cover plate and the 3mm x 20mm screws - 29 - Lanry Instruments www.lanry-flow.com...