lanry WM9100 Series Manual

Residential ultrasonic water meter for dn15/dn20/dn25
Hide thumbs Also See for WM9100 Series:

Advertisement

Quick Links

WM9100 Series
Residential Ultrasonic Water Meter
( For DN15/DN20/DN25 )
Lanry Instruments (Shanghai) Co.,Ltd
( V1.0/2022)

Advertisement

Table of Contents
loading

Summary of Contents for lanry WM9100 Series

  • Page 1 WM9100 Series Residential Ultrasonic Water Meter ( For DN15/DN20/DN25 ) Lanry Instruments (Shanghai) Co.,Ltd ( V1.0/2022)
  • Page 2 WM9100 Series Ultrasonic Water Meter Manual Notice Dear users, In order to your quick understanding of our product features and use of the product correctly, please read the manual carefully before installing and operating.  Please check the packing list and confirm whether your received goods are the same as your ordered goods.
  • Page 3 WM9100 Series Ultrasonic Water Meter Manual specially and professionally  Please change the battery when it is low power, to avoid data loss. When changing the battery, it must be operated by professionals, or return the product to our company.
  • Page 4: Table Of Contents

    WM9100 Series Ultrasonic Water Meter Manual CONTENT 1. Summary ........................1 2. Feature ........................... 1 3. Specifications ......................... 2 4. Operation ........................3 1) Main Menu ......................4 2) Error Menu【E】 ....................5 3) Information Menu [I] ....................6 4) Testing Menu [F] ....................7 5.
  • Page 5: Feature

    Ultrasonic water meter is a new type of water meter which can measure and display the flow rate according to the time difference between upstream and downstream when the ultrasonic wave propagates in the water. Water meter can be equipped with wired or wireless data communication interface to communicate with the collector, concentrator or network server to form a remote meter reading management system.
  • Page 6: Specifications

    3. Specifications Max. Working Pressure 1.6Mpa Temperature Class Accuracy Class ISO4064, Accuracy Class 2, Optional Class 1 Body Material Stainless SS304 (opt. SS316L) Battery Life 6 Years (Consumption<0.3mW) Protection Class IP68 Environmental Temperature -40~70℃, ≤100%RH Pressure Loss AP25, AP40 ( Based on different dynamic flow ) Climatic And Mechanical Class O Environment...
  • Page 7: Operation

    4. Operation This water meter adopts LCD screen combined with digital and graphic to present measurement parameters and working status information to users, as shown below: User can use magnetic bar to touch the magnetic induction area on the water meter shell to switch different function menu.
  • Page 8: Main Menu

    3) Information Menu 【 I 】 :Display water meter address, communication parameter and historical data 4) Testing Menu【F】:Use this menu when testing This water meter is usually displayed by default LCD, the main menu is fixed to show cumulative flow. Use Press and Hold can loop through 4 menus. Use Press and Leave can shift in this level menu.
  • Page 9: Error Menu【E

    c. Accumulated working time (hour) d. Pipe diameter e. Full screen Error Menu【E 】 Remarks: Number 1-8 is fault code.
  • Page 10: Information Menu [I]

    Occurred time (year/month/day) 1Battery fault Occurred time (year/month/day) 2 Empty pipe fault Occurred time (year/month/day) 3 Reverse flow fault Occurred time (year/month/day) 4 Over range fault Occurred time (year/month/day) 5 Water temperature fault Occurred time (year/month/day) 6 EE fault Occurred time (year/month/day) 7 Sensor fault(water inlet) Occurred time (year/month/day) 8 Sensor fault(water outlet)
  • Page 11: Testing Menu [F]

    Notice: If the meter reading freeze time is displayed as "NULL", it means that there is no historical data on that date. 3) Testing Menu [F]...
  • Page 12: Infrared Meter Reading

    5. Infrared Meter Reading 6. Users can be equipped with a hand-held meter reading machine to record the accumulated flow, running time and other information of the water meter. The meter reading method can refer to the operation instructions of the handheld machine. 7.
  • Page 13 For horizontal installation, it is recommended to install as above and make the pipe line into "U". In vertical installation, as shown in the figure above, the water flow direction is inflow at the water meter at the lower end and outflow at the upper end. In this case, when water flows through, bubbles can be avoided to gather in the meter measuring pipe.
  • Page 14: Precautions Before Installation

    Compromised installation (horizontal) If it is difficult to implement the recommended horizontal installation conditions due to the objective conditions on site, at least install as shown below. In the figure, the pipe section in front of the water meter can be parallel to the water meter body (the right-angle bending structure is eliminated compared to the recommended method), but the pipe at the back of the water meter must be arranged as shown in the figure, so as to avoid bubbles forming in the pipe.
  • Page 15: Common Error Installation Examples

    (4) The connecting pipes upstream and downstream of the ultrasonic water meter should be consistent with the diameter of the water meter and should not be reduced; (5) The direction indicated by the arrow on the surface body of the ultrasonic water meter is the direction of water flow, and reverse installation is not allowed.
  • Page 16: Wire Connection

    (3) When the meter is installed at the elbow, it must be ensured that the distance between the front straight pipe ≥5 times the pipe diameter and the rear straight pipe ≥ 3 times the pipe diameter, otherwise the meter may be inaccurate (as shown in Figure E). >5D (4) When the valve or other objects are installed in front of the meter, the distance between the meter and this object must be ≥5 diameters, otherwise the meter may be inaccurate;...
  • Page 17: Daily Maintanance

    M-BUS communication mode: connect two communication wires with M-BUS directly, without positive and negative pole. RS485 communication mode: there are 4 pieces of wires: A(Yellow), B(Green), Ground(Black), Power(Red), DC(7.5~24V), connect correspondingly (pay attention to the pole, the meter will be burned down if connect incorrectly) 5) Daily Maintenance (1)Please check the meter condition before using.
  • Page 18: Rs485 Modbus Protocol

    8. RS485 Modbus Protocol 1) Protocol Instruction 1. RS485 meter reading 一 Using RS485 communication hardware for 4-wire system long-distance serial communication. 2. 2.Totally 4 wires 一 A, B, Ground and Power 9-24V, the default 12V. 3.There are 4 wires on the water meter A(yellow), B(green), Ground(black), Power(red, 9-24V), correspondingly connected(different polarity, wrong connection may be burned).
  • Page 19: Modbus Baud Rate Setup

    Instrument type and its code Meter Type Code Water meter Heat meter Address field AO〜A6 consists of seven bytes, each byte is in 2-bit BCD code format. The address length is 14 decimal digits, the low address is first, and the high address is last.
  • Page 20: Modbus Address Setup

    e.g.: Baud rate switch to 9600,N,81. Data analysis format is integer data. 4) Modbus Address Setup To prevent modification, Modbus command cannot change the address directly, it needs to be modified by Cj188 protocol. Details as follows: e.g.: Set Modbus address is 01, send data as follows: FE FE FE 68 20 FF FF FF FF 04 74 68 15 0A A0 18 AA FF FF FF FF 01 11 11 04 16 Set modbus address is 02, send data as follows:...
  • Page 21: Modbus Application Protocol

    05 16 Therein 04 74 68 is factory code, provided by manufacturer, also can be checked in the first interface through [I] menu. 01,02 are the address of Modbus. 5) ModBus Application Protocol 1. ModBus Integer Command Read An example of the command sequence sent by the host: ModBus address: 0x01 (integer format register address must start with 01) Command code: 0x03 Register start address high byte: 0x00...
  • Page 22 Data Register Address Number Of Bytes Data Content Format register address 0 Instantaneous flow rate register address 1 register address 2 Positive cumulative flow register address 3 register address 4 Cumulative daily traffic in register address 5 the last month register address 6 Cumulative working time register address 7...
  • Page 23 Specific analysis examples The host sends the command sequence: 01 03 00 00 00 1A C4 01 The slave responds to the command sequence: 01 03 34 3F 7D 40 D9 0F C5 42 0F 85 1F 41 45 B4 38 49 96 00 00 40 00 85 1F 41 45 FE F4 3E 94 E1 48 41 E4 00 00 00 00 00 00 00 00 00 000 28 24 09 19 01 4C 2B ModBus address: 0x01 Command code: 0x03...
  • Page 24 As shown in the table above, the third screen of the [I] menu displays the following content, 2400 even parity, modbus address 02,The software settings are as follows: (1) Integer data read: Device Id (meter address LocalAdress) is set to 2, MODBUS Point Type (command word) is set to 03, Address (data address) is set to 0002 (it should be address 1, but this software will automatically The address is reduced by one, so it is changed to 2), and the Length (data length) is set to 38.
  • Page 25 Integer data read: The floating-point address can start from 0, and the 449A4000 corresponds to a single-precision floating-point decimal accumulation of 1234 cubic meters.
  • Page 26 2. Communication Test Software How to use: 1234 steps as shown below 1. Set the communication parameters (COM5, 2400, even parity, data bit 8, stop bit 1) and open the serial port 2. MBUS read address, get manufacturer address 687508 3.
  • Page 27: Warranty

    10. Warranty The ultrasonic water meter defaults to a free warranty within one year from the date of shipment.(Customers can pay extra to extend the free warranty period, maximum is 6 years), lifetime maintenance. However, damage caused by the following conditions is not covered by the warranty: 1) The seal signs of each part of the ultrasonic water meter are opened or destroyed.
  • Page 28 Suitable for products of Lanry instruments(Shanghai) Co.,Ltd 3) Details (1) Regulations on waste products and emissions. (2) Dispose of all waste products properly. (3) When handling and disposing of the treated liquid, comply with applicable environmental regulations. Clean up all spilled liquids according to safety and environmental protection regulations, and report all environmental emissions to relevant departments.

Table of Contents