7.4

Connecting cable

The connecting cable is an industrial cable, can tolerate bending in-line with what is required in
practice – and is resistant to many solvents and lubricants.
The connecting cable is available in various lengths. You will find detailed information in
Section: "Accessories".
Figure 7-9
The connecting cable is connected to the HT 8 using the RJ45 plug connector
connector
terminal box/connecting module MPP. The tightening torque for the nut of the ODU socket is
6.5 Nm.
The HT 8 has two cable entries at the rear for connecting the cable. This makes it possible to
attach the connecting cable at either the right or left side.
One of the cable entries is closed at the factory by a connector in which a USB connection is
integrated (with IP65 cover).
Routing the connecting cable
 
Handheld Terminal HT 8
Equipment Manual, 02/2024, A5E52918633B AA
Metallic push-pull round connector (ODU connector)
RJ45 plug to connect to the Ethernet
Plug connector for enabling button, Emergency Stop, 24 V and safety signals
Strain relief device and kink protection
Connecting cable for the HT 8
. ODU plug connector
is used to connect the connecting cable with the
1. Open the cover by unscrewing the six PT screws
(4 x 20 mm) approximately 1 cm.
To do this, use a Phillips size 2 screwdriver.
 
 
Connecting
7.4 Connecting cable
and plug
111