Download Print this page

F&F STR-421 Instruction Manual page 7

Roller blind controller 2-button

Advertisement

5. Connect the controlled roller shutter motor to terminals 10
and 12 and to N respectively.
6. Connect the motor power supply (L) to terminal 11.
7. Connect power supply.
8. Programme raising/lowering time for the roller shutter. It is
recommended that the programmed time is approx. 10 s lon-
ger than the actual raising/lowering time of the roller shutters.
Technical data
power supply
maximum load current (AC-1/AC-3)
power of connected single-phase motor
control
control pulse current
switch-on time (programmable)
power/programming indication
activation indication
power consumption
working temperature
terminal
tightening torque
dimensions
mounting
ingress protection
The controller uses a relay with a contact strength of 8
A for resistive load. Due to the inductive nature of the
load introduced by the roller shutter motor, the contact
should not be loaded with more than 1.5 A. This corre-
sponds to a motor power of approx. 320 W.
triggered by level L or N
2.5 mm² screw terminal
- 7 -
195÷253 V AC
8 A/1.5 A
320 W
0 s÷10 min.
green LED
2× red LED
-25÷50°C
0.4 Nm
1 module (18 mm)
on TH-35 rail
<1mA
<1 W
IP20

Advertisement