Connecting 1-Phase Input Power For 240 Vac - Miller Multimatic 220 Owner's Manual

Table of Contents

Advertisement

A complete Parts List is available at www.MillerWelds.com
5-6.

Connecting 1-Phase Input Power For 240 VAC

3
6
8
L1
L2
240 VAC, 1
Complete Parts List is available at www.MillerWelds.com
1
=GND/PE Earth Ground
7
2
4
L1
5
L2
1
input4 2012-05
803 766-C / Ref. 802 443-A / 275173A
Installation must meet all National
and Local Codes—have only quali-
fied persons make this installation.
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow es-
tablished
procedures
the installation and removal of
lockout/tagout devices.
Always connect green or green/
yellow
conductor
grounding terminal first, and never
to a line terminal.
NOTICE – The Auto-Line circuitry in this unit
automatically links the power source to the
primary voltage being applied, either 120 or
240 VAC.
See rating label on unit and check input volt-
age available at site.
1 Input Power Cord
2 Disconnect Device (switch shown in the
OFF position)
3 Disconnect Device Grounding Terminal
4 Disconnect Device Line Terminals
5 Black And White Input Conductor (L1
And L2)
6 Green
Or
Green/Yellow
Conductor
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to dis-
connect device line terminals.
7 Over-Current Protection
Select type and size of over-current protec-
tion using Electrical Service Guide (fused
disconnect switch shown).
8 Receptacle (NEMA 6– 50R) Customer
Supplied
Close and secure door on disconnect device.
Follow established lockout/tagout proce-
dures to put unit in service.
OM-281426 Page 21
regarding
to
supply
Grounding