0 -7 5/16 _CH
[185]
^
2 -4 S/16'-°1
[719]
r n
1
1
7/8
[352]
FILTER ACCESS PANEL
(DISPOSABLE FILTERS)
0 -4
ClOl]
1 '-0 5/8'
C320]
I
ACCESSORY
K"
HOOD FILTER
2 -2 7/lB
CB71]
0'-7 1/16'
[179]
NOTES;
1
Dimensions in
1
Dimensions in [ ] are in miilimeters
Center of gravity
-0'-5 11/16
[144]
OUTSIDE
OF PANEL
/
RETURN
AIR
E STD CONDENSATE DRAIN -
Direction of airflow
Onvertical discharge units, ductwork to be attached to accessory roof curb
only For horizontal discharge units, field-supplied flanges should be at¬
tached to horizontal discharge openings and all ductwork should be at¬
tached to the flanges.
Minimum clearance (local codes or jurisdiction may prevail):
a Bottom to combustible surfaces (when not using curb) zero in on ver¬
tical discharge units, and one in on horizontal discharge units,
b. Condenser coil, for proper airflow, 36 in. one side, 12 in. the other The
side getting the greater clearance is optional
c Overhead, 60 in to assure proper condenser fan operation
d
Horizontal supply and return end, zero inches,
e
Between units, control box side, 42 in per NEC
f
Between unit and ungrounded surfaces, control box side, 36 in. per NEC
g Between unit and block or concrete walls and other grounded surfaces,
control box side, 42 in per NEC
With the exception of the clearance for the condenser coil as stated in Notes
5b and c, a removable fence or barricade requires no clearance
Units may be installed on combustible floors made from wood or class A,
B, or C roof covering material.
RIGHT SIDE
CONNECTION SIZES
1 %" dia [35] field power supply hole
2^2" dia [64] power supply knockout
13
/
4
" dia [44] charging-port hole
%" dia [22] field control wiring hole
3/4''-14 NPT condensate drain_
2" dia [51] power supply knockout
REAR
FILTER/ECONOHIZER ACCESS PANEL-
CONDENSER COIL -A
2
'-ll 1/2
— [902] —
0'-3 9/16'
[90]
4'-S 3/4
[1 467]
LEFT SIDE
ELECTRICAL
DISCONNECT LOCATION
r-5 7/8'
[454]
0'-3 1/6'
[79]
1 '-0 5/8
[320]
2'-4 3/4
[730]
0-5 1/2
_ [140]
r-11
1/4
[591 ]
I
0'-5 7/16
L
J
^'-3 1/8'^^CORNER 'C'
7 -3 3/0
[2219]
FRONT
0'-7 3/8'
[187]
■ 0 -3 13/16'
[97]
0 -0 3/8
[
10
]
CONDENSER COIL
CONTROL BOX AND
EVAPORATOR-FAN MOTOR,
COMPRESSOR ACCESS PANEL
BLOWER AND ELECTRIC
HEAT ACCESS PANEL
0 -4 9/16'
[116]
0'-2 9/16^'
[65]
TYP
-4'-5 7/81
Cl 369]
LEFT SIDE
0'-5 3/4'
[146]
0'-2 1/4
[57]
CTYP 8 PLACES)
FRONT
Fig. 6 — Base Unit Dimensions