Existing Fireplace Requirements; Chimney Specifications - Breckwell BH2613i Manual

Table of Contents

Advertisement

WARNING: This appliance must be vented to the
outside. The venting system must NEVER be attached
to a chimney serving a separate solid fuel burning
appliance. Each gas appliance must use a separate
vent system. Do not use common vent systems.
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your authorized
dealer if any damage is found. Do not install any
damaged, incomplete, or substitute parts. Check your
packing list to verify that all listed parts have been
received.
APPLIANCE PLACEMENT CONSIDERATIONS
WARNING: Due to high surface temperatures, the
fireplace insert should be located out of traffic and
away from furniture and draperies.
• This fireplace insert must be installed on a level
surface capable of supporting the fireplace insert
and venting.
• This fireplace insert may be installed in a bedroom.
• Please be aware of the large amount of heat this
fireplace insert will produce when determining a
location.
EXISTING FIREPLACE SPECIFICATIONS
CAUTION: Adequate accessibility clearances for
servicing and proper operation must be maintained.
• Any smoke shelves, shields, and baffles may be
removed if attached by mechanical fasteners. If
necessary, remove firebrick to obtain at least the
minimum opening requirements.
• Cutting of any sheet metal parts of the existing
fireplace is prohibited.
• If the metal floor is removed, the insert must be
placed directly on metal base of metal fireplace.
Mechanically attach "THIS UNIT HAS BEEN MODIFIED"
label at bottom of existing firebox so it will be visible if
this gas fireplace insert is removed.
Part Overview

Existing Fireplace Requirements

WARNING: Do not pack the open air spaces with
insulation or other materials. This could cause
high temperatures and may present a fire hazard
and serious injury, property damage or loss of life.
Operation of improperly installed and maintained
venting system could result in serious injury, property
damage or loss of life.
AA BATTERIES (4 PACK)
9V BATTERY BOX
AAA BATTERIES (3 PACK)
REMOTE
EXISTING FIREPLACE OPENING MINIMUM
REQUIREMENTS
A
Height
B
Front Width
C Depth
D
Back Width

CHIMNEY SPECIFICATIONS

WARNING: Any chimney clean-outs must fit properly.
This fireplace insert is to be installed into a solid fuel
masonry or factory built non-combustible fireplace that
has been installed in accordance with the national,
provincial, state, and local building codes.
The existing chimney must be comprised of one of the
following:
• Factory-built
solid
minimum inside diameter
-8-
D
B
A
C
inches
mm
20
508
31
788
17
432
19
483
fuel
chimney:
7"
(178mm)