AEG TI64IB10FB User Manual page 29

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. A single wire must have a minimal
cross section in accordance with the table
below. Speak to your local Service Centre.
The connection cable may only be
replaced by a qualified electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
220-240 V~
N
N
L1
L2
220 - 240 V~
5x1,5 mm²
Green - yellow
N
Blue and blue
L1
Black
L2
Brown
400V2N~
N
L1
L2
Two-phase connection: 400 V2N~
5x1,5 mm² or 4x2,5 mm²
Green - yellow
N
Blue and blue
L1
Black
L2
Brown
CAUTION!
Do not connect the cable without cable
end sleeve.
One-phase connection
1. Remove the cable end sleeve from black,
brown and blue wires.
2. Remove a part of the insulation of the
brown, black and blue cable ends.
3. Connect the ends of black and brown
cables.
4. Apply a new wire end sleeve on the
shared wire's end (special tool required).
5. Connect the ends of two blue cables.
6. Apply a new wire end sleeve on the
shared wire's end (special tool required).
Two-phase connection
1. Remove the cable end sleeve from blue
wires.
2. Remove a part of the insulation of the
blue cable ends.
3. Connect the ends of two blue cables.
4. Apply a new end wire sleeve on the
shared wire's end (special tool required).
N
L
One-phase connection: 220
- 240 V~
5x1,5 mm² or 3x4 mm²
N
L
220-240 V~
Green - yellow
Blue and blue
Black and brown
ENGLISH
29

Advertisement

Table of Contents
loading

Table of Contents