Download Print this page

Milwaukee 045242541362 Operator's Manual page 5

Dual bay simultaneous rapid charger and li-ion battery packs

Advertisement

Charging a Hot or Cold Battery Pack
The Red Flashing Indicator light on the charger in-
dicates that the battery pack temperature is outside
the charging range. Once the battery pack is within
the acceptable range, normal charging will take place
and the red light will be continuous. Hot or cold bat-
teries may take longer to charge.
Li-Ion Charging Status
Battery Pack
Red Charger
Temperature
Indicator Light
Too Hot
Fast Flashing
Normal Range
Continuous
Too Cold
Fast Flashing
Powering the Charger with an Inverter
or Generator
The charger will operate with most 120-127 V gen-
erators and inverters rated at 500 Watts or higher.
Maintenance and Storage
Store your charger in a cool, dry place.
As a general practice, it is best to unplug battery
chargers and remove batteries when not in use.
No battery pack damage will occur, however, if the
charger and battery pack are left plugged in.
Repairs
The charger has no serviceable parts.
Mounting to the Wall
Use the wall mount guides to mark the hanging
points.
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery from the charger before performing any
maintenance. Never disassemble the battery or
charger. Contact a MILWAUKEE service facility
for ALL repairs.
To reduce the risk of injury and damage, never
immerse your battery or charger in liquid or allow
a liquid to flow inside them.
Cleaning
Clean out dust and debris from charger vents and
electrical contacts by blowing with compressed air.
Use only mild soap and a damp cloth to clean the
battery pack and charger, keeping away from all elec-
trical contacts. Certain cleaning agents and solvents
are harmful to plastics and other insulated parts.
Some of these include gasoline, turpentine, lacquer
thinner, paint thinner, chlorinated cleaning solvents,
ammonia and household detergents containing am-
monia. Never use flammable or combustible solvents
around batteries, charger, or tools.
Charging Status
Not charging
Normal charging
Not charging
5