Set Mode
Set Item 9 [ TX SAVE ]
Function: Enable/disable the Transmit Battery Saver.
Available Values: ON/OFF
Default: OFF
Set Item 10 [ APO ]
Function: Set the Automatic Power-Off time.
Available Values: OFF/30 min/1 hour/3 hour/5 hour/8 hour
Default: OFF
Set Item 11 [ TRX LED ]
Function: Enable/ disable the BUSY/TX LED while the Squelch is open or during trans-
mission.
Available Values: ON/OFF
Default: ON (Lamp active)
Set Item 12 [ ARTS ]
Function: Activate the ARTS feature.
See page 26 for details.
Set Item 13 [ ARTS BP ]
Function: Select the Beep option during ARTS operation.
Available Values: OFF/INRANGE/ALWAYS
Default: INRANGE
Set Item 14 [ AR ITVL ]
Function: Select the Polling Interval during ARTS operation.
Available Values: 15 SEC/25 SEC
Default: 15 SEC
Set Item 15 [ KEY BP ]
Function: Enable/disable the Keypad beeper.
Available Values: ON/OFF
Default: ON
Set Item 16 [ EDGE BP ]
Function: Enable/disable the Band-edge beeper while scanning.
Available Values: ON/OFF
Default: ON
Set Item 17 [ BELL ]
Function: Select the number of CTCSS Bell ringer repetitions.
Available Values: OFF/1/3/5/8/REPEAT
Default: OFF