Advertisement

Quick Links

OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
O
M
PERATING
ANUAL
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANMA K‹TABI
AIR CONDITIONER
DUCT TYPE
Indoor Unit
ARG90EL(3)
ARG90TL(3)
Outdoor Unit
AOG90EP(3)
AOG90TP(3)
KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК
BU KILAVUZU, DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN
FUJITSU GENERAL LIMITED
P/N9365751046

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARG90EL(3) and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for General ARG90EL(3)

  • Page 1 GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК BU KILAVUZU, DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN FUJITSU GENERAL LIMITED P/N9365751046...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........1 SYSTEM OPERATION ......... 11 NAME OF PARTS ........... 2 CARE AND MAINTENANCE ....... 11 PREPARATION ............3 OPERATING TIPS ..........12 OPERATION ............3 ERRORS AND SELF DIAGNOSIS ....... 13 TIMER OPERATION (OFF TIMER/ON TIMER) ..4 TROUBLESHOOTING ..........
  • Page 3: Name Of Parts

    NAME OF PARTS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Fig. 1 Fig. 2 Electrical Breaker Install this with the power sup- ply chain during on-site instal- lation. Fig. 3 NON STOP CLOCK TEMP AUTO...
  • Page 4: Preparation

    PREPARATION Set the Current Time and Day Press the CLOCK ADJUST button for more than three CLOCK AUTO AUTO seconds. DEFROST TEST Press the SET TEMP./DAY button and set the day. TIMER SET TIME TEMP./DAY MODE CONTROL L : Use to advance the day forward. MASTER CONTROL M : Use to turn the day back.
  • Page 5: Timer Operation (Off Timer/On Timer)

    TIMER OPERATION (OFF TIMER/ON TIMER) Before using the timer function, be sure that the remote controller is set to the correct current time and Day. Press the START/STOP button; after the unit starts operation perform the following procedure: OFF Timer/ON Timer Press the TIMER MODE button and display either OFF CLOCK TEMP...
  • Page 6: Timer Operation (Weekly Timer)

    TIMER OPERATION (WEEKLY TIMER) Use the weekly timer to set operating times for each day of the week. Weekly Timer Features G Set different operating times for each day of the week. G Set one or two operating spans (one or two ON times and one or two OFF times) per day. G Set time to a resolution of 5 minutes.
  • Page 7 Press the SET TIME button to set the day’s first OFF AUTO AUTO time. TIMER WEEKLY The earliest OFF time you can set is 5 minutes after the ON time. The DEFROST TEST latest OFF time is 23:55 on the subsequent day. TIMER SET TIME TEMP./DAY...
  • Page 8 TIMER OPERATION (WEEKLY TIMER) Starting Weekly Timer Operation Press the TIMER MODE button so that “WEEKLY” ap- CLOCK TEMP AUTO AUTO °C pears on the display. HIGH TIMER WEEKLY COOL DEFROST TEST Press the START/STOP button to start operation. TIMER SET TIME TEMP./DAY MODE...
  • Page 9 To Change Selected Time Settings Press the START/STOP button to stop the air conditioner, and then proceed as fol- lows. Carry out steps 1 to 3 of the “Setting Up the Weekly AUTO AUTO Timer Operation” procedure to select the day you want TIMER WEEKLY to edit.
  • Page 10 TIMER OPERATION (WEEKLY TIMER) About the DAY OFF G Use the DAY OFF setting to switch off timed operation for a selected day in the coming week. G This is a temporary, one-time setting. The DAY OFF setting is automatically cleared as soon as the specified day passes. Using the DAY OFF Setting Press the START/STOP button to stop the air conditioner, and then proceed as fol- CLOCK...
  • Page 11: Energy Save Operation

    ENERGY SAVE OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Use the ENERGY SAVE Press the ENERGY SAVE button. NON STOP CLOCK TEMP AUTO AUTO °C The unit will run in the ENERGY SAVE mode. HIGH COOL DEFROST TEST...
  • Page 12: System Operation

    SYSTEM OPERATION <Control Several Units with just one Remote Controller> Outdoor One remote controller can control up to 16 air conditioners. unit All the air conditioners can be operated with the same set- ting. Indoor unit Remote Unit No.1 Unit No.2 Unit No.16 controller To Use the ZONE CONTROL...
  • Page 13: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Please read and understand the following details regarding this air conditioner. Operation and Performance *Heating Performance *Microcomputer-controlled Automatic Defrosting G This air conditioner uses a heat pump which absorbs heat When the outside temperature is low and the humidity high, from outside air and brings it indoors.
  • Page 14: Errors And Self Diagnosis

    ERRORS AND SELF DIAGNOSIS Error Code Room temperature sensor shortcircuited AUTO AUTO Indoor heat exchanger temperature sensor open DEFROST TEST Indoor heat exchanger temperature sensor shortcircuited TIMER SET TIME TEMP./DAY MODE CONTROL MASTER CONTROL Outdoor heat exchanger temperature sensor open CLOCK ADJUST Outdoor heat exchanger temperature ZONE...
  • Page 15 Symptom See page Problem G During operation and immediately after stopping the unit, the NORMAL Noise is heard: sound of water flowing in the air conditioner’s piping may be FUNCTION — heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
  • Page 16: Specifications

    SPECIFICATIONS MODEL INDOOR UNIT ARG90EL(3) ARG90TL(3) OUTDOOR UNIT AOG90EP(3) AOG90TP(3) TYPE COOLING MODEL HEAT & COOL MODEL POWER 3N~380-415 V 50 Hz COOLING CAPACITY [kW] 25.4-25.4 24.8-25.4 POWER INPUT [kW] 10.5-10.5 12.2-12.5 CURRENT 17.0-17.0 19.5-19.5 ENERGY EFFICIENCY RATIO [kW/kW] 2.42-2.42 2.03-2.03 HEATING CAPACITY...
  • Page 17 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...

This manual is also suitable for:

Arg90tl(3)Aog90ep(3)Aog90tp(3)

Table of Contents

Save PDF