Sony RM-M7G Service Manual page 18

Remote control unit
Table of Contents

Advertisement

Manual adjustment
VTR
100
1
GAIN
OFF
2000
«OdB
@
CAMERA
9dB
ears
1808
W/B
BALANCE
°
8 &
MASTER GAMMA
PRESET A
MANUAL
'MANUAL
MASTER
PEDESTAL
REMOTE
CONTROL
UNIT
RM-M7G
Set the FILTER selector of the camera to the
appropriate position according to the lighting
conditions.
5 Set the IRIS AUTO/MANUAL switch to AUTO.
6 Point the camera at a white object (white wall,
white sheet, etc.) and zoom up on it.
2 Set the W/B BALANCE AUTO/PRESET/MANUAL
selector to MANUAL.
7
Turn the GAIN RED and BLUE controls to adjust
the white balance.
Adjust the balance while monitoring the waveform
on the waveform monitor.
3 Close the iris after setting the IRIS
AUTO/MANUAL switch to MANUAL.
Turn the PED RED and BLUE controls to adjust
the black balance.
Adjust the balance so that the monitor screen
becomes black as you monitor the output level on
the waveform monitor.
When the MODE selector is set to TEST and the test signal is
output, the gain and pedestal red and blue levels are set to
their preset values. You cannot adjust these items by using
the GAIN RED and BLUE controls and the PED RED and
BLUE controls.