Read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product datasheet. INCLUDED ITEMS Each Strand Leko LED Profile luminaire includes the following items: • Strand Leko LED Profile Tunable Cold White • Quick Start Guide...
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL 2 InsTallaTIOn MOUNTING The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s own weight.
Page 4
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL TABLE 1. MENU FUNCTIONS LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT address 001~512 (Default 001) leD Hours XXXXXX h reset leD Hour are you sure? square Curve...
Page 5
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL TABLE 1. MENU FUNCTIONS LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 DEFAULT address 001~512 ssCC (Default) DMX Mode sQCC sOCC Group 1 (Default) Pixel Group Group 3 Group 12...
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL aDDress MenU Address — DMX address setting. To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL Normal or Flipped, press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode. Data — To select Data, press the ENTER button to confirm. Use the UP/DOWN button to select Ch1 – Intensity xxx(value), Ch2 –...
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL 3 DMX MaPPInG The fixture can be operated by DMX controller. The following tables assumes a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in se- quence.
Page 10
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL TABLE 3. 8-BIT MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL Control Channel 0 - 255 Control Channel used for full fixture settings, lamp controls, and miscellaneous modes. set discrete value of desired effect, wait >3 seconds, then set value to 0 (Idle).
Page 11
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL TABLE 3. 8-BIT MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 100% = 6500K TABLE 4. 2 CHANNEL MODE PARAMETER DEFAULTS RANGE DMX DESCRIPTION CHANNEL 8 bit Intensity (Dimmer) Control Intensity 0 - 255 0 - 100% Output...
Page 12
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL TABLE 5. CONTROL CHANNEL RANGE POWER CYCLE FUNCTION ITEMS DESCRIPTION RULES SELECTION VIA UI ensures all fades between output levels remain Dimmer snap Off Holds setting on 66 - 70 smooth and flicker free limits fast instant snaps...
Page 13
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL LINEAR S-CURVE SQUARE LAW DMX OUTPUT DMX OUTPUT DMX OUTPUT W W W.Va r i - L i T e .C o M...
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL DMX512 CONNECTION • At last unit, the DMX cable has to be terminated with a terminator. Solder a 120Ω 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5-pin XLR-plug and plug it in the DMX-output of the last unit.
Leko LeD ProfiLe TunabLe CoLD WhiTe user ManuaL APPENDIX A Care anD MaInTenanCe TROUBLESHOOTING Following are a few common problems that may occur during operation. The unit does not work - light and fan do not turn on • Check the connection of power and main fuse.
Page 16
ManuaL Fan Speed and Control All Vari-lite and Strand lighting luminaires will be governed by the same Fan speed v Noise levels v Maximum power output rules as details below. These noises related to these levels will confirm to Noise Criteria levels details of...
IMPORTANT! When returning products to Strand for repairs (warranty or out-of--warranty) from a country other than the USA, “Strand Lighting LLC”, must appear in the address block as the Importer of Record (IOR) on all shipping documentation, Commercial Invoices, etc. This must be done in order to clear customs in a timely manner and prevent returns.