Positioning The Rooftop Component; Preparing To Work Inside The Rv - Dometic FreshJet 4 Series Installation Manual

Rooftop air conditioner (return air grille, wall thermostat controls)
Hide thumbs Also See for FreshJet 4 Series:
Table of Contents

Advertisement

Rooftop air conditioner (FreshJet return air grille, wall thermostat controls)
7 .4 .7 Routing an automatic generator
start (AGS) feature via RV-C (optional)
If installing an AGS feature, you must complete one of
the following actions:
• If the generator is equipped with RV-C
communication capabilities and an AGS device:
1. Ensure that the generator and AGS device are
configured on the network.
2. Set the values relevant to the AGS as prescribed
by the RV-C specifications.
• If the generator is equipped with RV-C
communication capabilities but not equipped with
an AGS device:
1. Install an RV-C compliant AGS interface device
on the network.
2. Set the values relevant to AGS as prescribed by
the RV-C specifications.
The generator can be configured on the RV-C network
without an AGS.
1. Install an RV-C interface device on the network.
2. Set the values relevant to GENERATOR_COMMAND.
7 .5 Positioning the rooftop
component
NOTICE: Do not slide the rooftop component along
a surface or damage to the gasket on the bottom of the
rooftop component could occur and cause a leak.
1. Remove all the contents from the carton and discard
the carton.
2. Place all the return air grille kit contents in the RV. The
return air grille kit contains mounting hardware for the
return air grille that will be installed inside the RV.
3. Move the rooftop component to the roof.
EN
11 Placing the rooftop component
Front of the rooftop
q
component
4. Peel the adhesive backer off the gasket.
5. Lift and place the rooftop component over
the prepared opening using the gasket on the
rooftop component as a guide.
I
The outside work is complete. Minor adjustments
can be made from inside the RV if required.

7 .6 Preparing to work inside the RV

This section describes the interior preparation.
1. Confirm the return air grille kit is inside the RV.
q q
12 Centering the rooftop component from inside the RV
Roof gasket
q
2. From inside the RV, check the gasket alignment of
the rooftop component over the roof opening. If
necessary, adjust the rooftop component from below
by gently pushing up.
Pre-installation
q q
w w
Roof opening
w
15

Advertisement

Table of Contents
loading

Table of Contents