SYJ Series
Be sure to read this before handling
Interface Regulator
Spacer type regulation valve on manifold block can regulate the
pressure to the valve individually.
Specification
Interface regulator
Applicable solenoid valve model
Regulating port
Proof pressure
Maximum operating pressure
Set pressure range
Ambient and fluid temperature
Thread size for connection of
pressure gauge
Weight (kg)
Effective area at exhaust
P→A
2
Note 3)
side (mm
)
S at P1=0.7MPa,
P→B
P2=0.5MPa
Effective area at supply
A→EA
2
Note 4)
side (mm
)
S at P1=0.7MPa,
B→EB
P2=0.5MPa
Note 1) Set the pressure within the operating pressure range of
the solenoid valve.
Note 2) The maximum operating temperature for the solenoid
valve is 50℃.
Note 3) The effective area listed is for a single solenoid 2 position
valve mounted on a sub-plate.
Note 4) Apply pressure from P port in the base for interface
regulator.
/ / / /
Specific Product Precautions 6
ARBYJ5000
ARBYJ7000
SYJ5000
SYJ7000
P
P
1.5MPa
1.5MPa
Note 1)
0.05 to 0.7 MPa
Note 2)
-5 to 60℃ (No freezing)
M5X0.8
0.06
0.09
1.9
5.1
2.1
5.8
4.5
12.6
4.5
12.6
- 13 -
No.SYJ3000-OMM0002-A
Need help?
Do you have a question about the SYJ Series and is the answer not in the manual?
Questions and answers