Download Print this page
NCR 7360-K991 Kit Instructions

NCR 7360-K991 Kit Instructions

Cr5000 coin recyclertype d validator module

Advertisement

Quick Links

Kit Instructions
CR5000 Coin RecyclerType D Validator Module
7360-K991
Issue A

Advertisement

loading
Need help?

Need help?

Do you have a question about the 7360-K991 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NCR 7360-K991

  • Page 1 Kit Instructions CR5000 Coin RecyclerType D Validator Module 7360-K991 Issue A...
  • Page 2 NCR, therefore, reserves the right to change specifications without prior notice. All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Software screen images are representative, and in some cases, may not match a customer’s installed software exactly.
  • Page 3 Revision Record Issue Date Remarks Nov 2021 First issue.
  • Page 4: Kit Contents

    Preferred Offer that requires converting units from Euro currency to Czech support. The conversion involves removing existing Type B Validator Module and installing Type D Validator Module. This publication provides procedures for replacing a Type B Validator Module with a Type D Validator Module in an NCR FastLane SelfServ™ Checkout (7360). Kit Contents...
  • Page 5: Installation Procedures

    CR5000 Coin Recycler Type D Validator Module Installation Procedures To convert units from Euro currency to Czech support, replace the existing Type B Validator Module with a Type D Validator Module by doing the following procedures: • Removing the Validator Module on the facing page.
  • Page 6 CR5000 Coin Recycler Type D Validator Module Removing the Validator Module To remove the existing Validator Module, follow these steps: 1. Access the CR5000 Coin Recycler (cpi™). 2. Turn the Service screw, located behind the Validator on the CR5000 Coin Recycler Chassis, clockwise at approximately ¼...
  • Page 7 CR5000 Coin Recycler Type D Validator Module 3. Slide up and then lift the existing Validator module as shown below. Ensure that the connector and cable are not strained. Warning: The validator is connected to the chassis using a short-length cable with a non-latching connector end.
  • Page 8 CR5000 Coin Recycler Type D Validator Module Installing the Validator Module To install the Validator Module, follow these steps: 1. Remove the existing Validator Module. For more information, refer to Removing the Validator Module on page 3. 2. Connect the cable to the Validator connector. 3.
  • Page 9 CR5000 Coin Recycler Type D Validator Module 4. Turn the Service screw, located behind the Validator on the CR5000 Coin Recycler Chassis, counterclockwise at approximately ¼ turn to secure the Validator Module in place. The screw locks in this position.
  • Page 10 6. Turn on the 7360 (R6-C) unit. The ADD/CADD window is displayed, showing available devices. Note: The NCR FastLane SelfServ(TM) Checkout application automatically runs and installs all available devices. If the new or replaced device is not listed in the ADD/CADD window, an error message is displayed.