Samsung SR-S2026C Service Manual page 59

Hide thumbs Also See for SR-S2026C:
Table of Contents

Advertisement

(Forced Operation)
(Forced Defrost)
It is a function to make R defrost or R and F defrost at a time regardless of defrost time,
Reference No. 8) Circuit Par Service Material List
<Eject Motor Check>
Check Method for Motor when EJECT
MOTOR does not operate.
2. Check the resistance value between (@) and
@ of CN9O, connector, of Load Terminals.
3. If the resistance value is between 18 and
22 Q, itis normal.
4. If the value is 0 Q, itis SHORT fault. Check
the wire connection state and Motor.
5. If the value is o Q, it is OPEN type and
check the wire connection line.
MAIN PCB
ASSY
<TEST Operation method>
8 Pieces of Wire
TEST S/W
CODE-NO
Product Name
| 1 | DA4i-o0024a
DA41-00027A
MAIN PCB ASS' Y
Basic Type
1
DA41-00020B
fT
Fe a Water Disp Tipe
FR ROOM SENSOR
[6 DAs2101080" | Outside Air Senso
[-7_| paae-1o1ogn |
F-EVA SENSOR | _5O2AT(@40mm) [1
S02AT(370mm)
| 9 | DA27-00002A
NOISE FILTER
CAN TYPE
| 10 | 3301-00016
FERRITE CORE
Quantity | Remark
1
Basic Type
ioe & Water Disp Tyne
Common Use

Advertisement

Table of Contents
loading

Table of Contents