4.13 Information on failure display
and trouble-shooting
Refrigerators with an electronics system
(MES, AES) indicate the occurence of a mal-
function by the LED or display flashing.
If a malfunction occurs, the indicator LED
"Failure" (1) flashes simultaneously. In the
case of AES models an acoustic alarm
sounds.

4.13.1 Status messages on the display

1
2
Display :
MES
LED is flashing
LED is flashing
LED is flashing
All temperature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
LED + all tempe-
rature setting
LEDs are flashing
3
Fig. 39
AES
"120" is flashing
"12" is flashing
"GAS" is flashing
All temperature setting
LEDs are flashing
"HE1" is flashing
"HE2" is flashing
25
Refrigerator operation
1
2
1 = Indicator LED failure
2 = Operating mode display
3 = Temperature level display
Failure :
120V mode: "120V" not available or voltage too
low
12V mode: "12V" not available or voltage too low
GAS/Auto mode: Flame not ignited
Temperature sensor defective, refrigerator works
on mid temperature setting
120V - Heating element defective
12V - Heating element defective
3
Fig. 40