Mode
Fig. 14
Press button "1" several times until the indica-
tor LED "6" GAS illuminates.
The device is now in manual gas mode. When
you select the automatic mode (the display
shows AU), GAS is only selected as energy opti-
on according to the sequence of priority when
none of the two electrical types of power supply
is available.
6
Fig. 16
In automatic mode, AU and the currently used
type of power supply (e.g. GAS) are indicated
alternately.
Switching over to a manual energy selection is
possible at any time.
Refuelling while in AES mode operation
In order to prevent unintended switching to gas
operation during refuelling, the electronic
system starts gas operation of the refrigerator
after the motor has been turned off for 15 minu-
6
tes. During this period the appliance is ready for
operation ("stand-by"). In automatic mode the
"AU" indication only is illuminated.
Fig. 15
The use of unshielded flames is prohibited
in petrol station environments.
Should the refuelling stop last longer than
15 minutes, the refrigerator has to be swit-
ched off or switched over to another energy
type.