TECALEMIT HORNET W 85 H Operating Manual
Hide thumbs Also See for HORNET W 85 H:

Advertisement

Quick Links

Operating manual
HORNET
W 85 H
Item-No.:
108500001, 108500100, 108500101, 108500200, 108500300,
108501102, 108501202, 108501302, 108502100, 108502200, 108502300,
108510001, 108510100, 108510101, 108510200, 108510300, 108511102,
108511202, 108511302, 108700100, 108701102, 108702100, 108710100,
108711102

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HORNET W 85 H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TECALEMIT HORNET W 85 H

  • Page 1 Operating manual HORNET W 85 H Item-No.: 108500001, 108500100, 108500101, 108500200, 108500300, 108501102, 108501202, 108501302, 108502100, 108502200, 108502300, 108510001, 108510100, 108510101, 108510200, 108510300, 108511102, 108511202, 108511302, 108700100, 108701102, 108702100, 108710100, 108711102...
  • Page 2 Technical changes reserved. Service Hotline +49 1805 900 301 (0.14 €/min. from the German landline network, cellular phone max. 0.42 €/min.) service@tecalemit.de Document Number: 44 1642 101-H As of: 25.07.2019 44 1642 101-H HORNET W 85 H...
  • Page 3: Table Of Contents

    6.3. Cleaning the system ..................... 12 Spare parts ......................13 Disposal ....................... 13 8.1. Return of batteries ....................13 Dimension drawing of the HORNET W 85 H ..........14 10. Declaration of Conformity ................14 44 1642 101-H HORNET W 85 H...
  • Page 4: Safety Instructions

    The device has been constructed for use with water contaminants. It is to be operated such that bodies of water cannot be polluted by it. All applicable regulations at the place of operation are to be complied with! 44 1642 101-H HORNET W 85 H...
  • Page 5: Technical Description

    / fuel tank or on a wall console. The HORNET W 85 H must not be operated with flammable or explosive liquids with a flash point of below 55 °C (hazard classes AI, AII and B). Liquids with a flash point above 55 °C (hazard class A III) must not be transported if they are heated beyond...
  • Page 6: Product Variants

    2.2. Product variants The product numbers and equipment variations of the HORNET W 85 H INOX are arranged according to the follow pattern: Art no. 108500001 108500100 108500101 108500200 108500300 108501102 108501202 108501302 108502100 108502200 108502300 108510001 108510100 108510101 108510200...
  • Page 7: Authorized Mediums

    2.3. Authorized mediums All versions of the Hornet W 85 H pump can transport diesel and EL heating oil. The basic pumps without nozzle and suction line, item no. 108500001 and 108510001, can also transport bio-diesel, anti-freeze (concentrated and mixed) and water.
  • Page 8: Installation Instructions

    Refer to the assembly instructions for details on the return flow set. 16. Screw the dispensing hose (5) onto the siphon protection**. *Part of the wall console accessories. **Part of the return flow set for siphon protection. 44 1642 101-H HORNET W 85 H...
  • Page 9: Place Of Installation

    3.5. Siphon protection The HORNET W 85 H is provided with siphon protection. During operation, the medium continually flows from the siphon protection opening on the underside of the pump which has to be redirected into the tank.
  • Page 10: Pumping Line

    (goggles and protective gloves). More information can be taken from the safety data sheet of the medium being transported. The HORNET W 85 H electric pump may only be operated under supervision. 4.1. Aspiration / dry running The HORNET W 85 H pump works according to the self-priming hybrid pump principle.
  • Page 11: Tank Process

    Caution! If the pump does not prime, increase the rotational speed. If the speed setting wheel is at the maximum (+) and the pump still does not prime, then the error is not due to the rotational speed setting. 44 1642 101-H HORNET W 85 H...
  • Page 12: Faults - What To Do When

    If the noise is excessive, further operation is only permitted following elimination of the cause! 6. Maintenance The HORNET W 85 H is virtually maintenance-free, however the following work should be carried out at regular intervals in order to ensure fault-free operation. 6.1. Seal checks The equipment and other components in the system must be checked regularly for leaks and damage and any leaks or damage repaired.
  • Page 13: Spare Parts

    (Cd, Hg or Pb) of the heavy metal that is decisive for the classification as containing harmful substances: 1. “Cd” stands for cadmium. 2. “Pb” stands for lead. 3. “Hg” stands for mercury. 44 1642 101-H HORNET W 85 H...
  • Page 14: Dimension Drawing Of The Hornet W 85 H

    9. Dimension drawing of the HORNET W 85 H 10. Declaration of Conformity 44 1642 101-H HORNET W 85 H...
  • Page 15 44 1642 101-H HORNET W 85 H...
  • Page 16 HORN GmbH & Co. KG Munketoft 42 24937 Flensburg Germany T +49 461-8696-0 F +49 461-8696-66 www.tecalemit.de info@tecalemit.de 44 1642 101-H HORNET W 85 H...