Robert Juliat ALICE Series Manual

Led followspots
Hide thumbs Also See for ALICE Series:
Table of Contents

Advertisement

Quick Links

LED FOLLOWSPOTS
OZ 1169TC / ALICE 1469TC (TOP CONTROL)
Angles
Controls
Standard / CE
7 – 14,5°
On top
1169TC (v3)
1469TC
13 – 24°
On top
Product version:
V3
Software:
FIRMWARE V4.00
Date: 19/01/24
DN41135201 (EN)
Robert Juliat S.A.S. 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - info@robertjuliat.fr
600 W LED
Model
North American
1169CTC (v3)
1469CTC
(v3)
(v3)
www.robertjuliat.com
OZ 1169 / ALICE 1469
Angles
Controls
Standard / CE
7 – 14,5°
On the side
1169 (v3)
1469
13 – 24°
On the side
Model
North American
1169C (v3)
1469C
(v3)
(v3)

Advertisement

Table of Contents
loading

Summary of Contents for Robert Juliat ALICE Series

  • Page 1 13 – 24° On the side (v3) (v3) (v3) (v3) Product version: Software: FIRMWARE V4.00 Date: 19/01/24 DN41135201 (EN) Robert Juliat S.A.S. 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - info@robertjuliat.fr www.robertjuliat.com...
  • Page 2: Table Of Contents

    4.9.1 Range...........................23 4.9.2 Control ........................23 4.10 Horizontal chopper .....................24 4.10.1 Range ........................24 4.10.2 Control ........................24 Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
  • Page 3: User's Instructions

    1 User’s instructions GENERAL INSTRUCTIONS Not for residential use. These fixtures must only be serviced by a qualified technician. In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU Directives must be adhered to at all times. This fixture is in compliance with section 17 - Lighting appliance for theatre stages, television, cinema and photograph studios.
  • Page 4: Presentation

    2 Presentation 2.1 Functions Description Yoke 10. Spare filter Yoke locking 11. Gobo holder Side operating 12. Local display Iris control (1169/1469 only) 13. Identification plate 4*. Iris control (1169TC/1469TC only) 14. Data connectors (OUT and IN) Dimming control (1169/1469 only) 15.
  • Page 5: Identification Label

    2.2 Identification label Description 1. MOD. : Model 18 15 16 2. VERS. : Version 3. U : Nominal voltage input (V) 4. I : Nominal intensity (A) 5. P : Maximum power input (W) 6. IP : International Protection Rating 7.
  • Page 6: Optional Accessories

    2.4 Optional accessories Reference Description T1000 TV spigot with followspots swivel head Monopod stand for overhead followspot GT4000 Tripod stand with safety chain - SWL: 130 Kg - max. height: 1030 mm GT4000S Tripod stand without safety chain - SWL: 130 Kg - max. height: 1030 mm T4000 Followspot mount for Ø50mm pipe (suspension or overhead) - SWL= 100 Kg CAV700A...
  • Page 7: Set-Up

    3 Set-up 3.1 Mechanics 3.1.1 Operating positions 3.1.2 Minimum distance between a flammable material and the lighting unit OZ: 1,5 m / 4.9 ft ALICE: 1,5 m / 4.9 ft 3.1.3 Instructions for use Minimum : Maximum : 5°C 40°C 40°F 104°F IP20 - Indoor use only...
  • Page 8: Stand Set-Up

    3.1.5 Stand set-up The unit must be installed only on a Robert Juliat compatible stand / head : T1000 TV spigot with followspots swivel head Monopod stand for overhead followspot GT4000 Tripod stand with safety chain - SWL: 130 Kg - max. height: 1030 mm GT4000S Tripod stand without safety chain - SWL: 130 Kg - max.
  • Page 9: Electrical Information

    3.2 Electrical information 3.2.1 LED source Never touch or scratch the LED surface. Cf. 6.1.4 LED cleaning procedure if cleaning is necessary. 3.2.2 Power supply Power supply Voltage Frequency Input power Connectors 3 A / 660 W @ 230V ® powerCON TRUE1 TOP Neutrik 5.8 A / 680 W @ 120V 100 T 264 V...
  • Page 10: Data

    Power ON 3.3 DATA 3.3.1 DMX 512-A / RDM Protocol Input connector Output connector USITT DMX 512-A XLR 5-pin XLR 5-pin DATA connectors PIN # Description Shielding Foil & Braided Shield DMX (-) conductor of 1 twisted pair DMX (+) conductor of 1 twisted pair Not used...
  • Page 11: Art-Net / Sacn

    3.3.2 Art-Net / sACN Protocol Input connector Output connector Art-Net (V3 & V4) RJ45 sACN DUAL (SACN + Art-Net) Art-Net sACN Network switch* Lighting desk interface (*) A 1000 base-T switch that supports IGMP (Internet Group Management Protocol) is necessary if the unit is connected to a network switch to control multiple devices.
  • Page 12: Accessories

    3.4 Accessories 3.4.1 Full closing iris cassette TC models only 3.4.2 Colour changer unit - boomerang (only available for OZ) Dimensions Cf. 4.8.1 EN - 10 -...
  • Page 13: Colour Changer Unit - Push-Pull (Alice)

    3.4.3 Colour changer unit - push-pull (ALICE) Dimensions Cf. 4.8.1 3.4.4 Gobo holder 'A' size gobo Dimensions Cf. 4.7.1 EN - 11 -...
  • Page 14: Double Slot Front Cassette For 215 X 215 Mm Accessories (Option)

    3.4.5 Double slot front cassette for 215 x 215 mm accessories (option) 3.4.6 Frosted / CTO glass (option) Dimensions: Cf. 4.9.1 EN - 12 -...
  • Page 15: Internal Glass Holder 120 X 120 Mm (Option)

    3.4.7 Internal glass holder 120 x 120 mm (option) 3.4.8 Horizontal chopper (option) Turn, to lock into place. Dimensions: Cf. 4.10.1 EN - 13 -...
  • Page 16: Stands

    3.4.9 Stands • GT4000 Series : Please refer to the relevant stand technical files for further details. Stand set-up, refer to Cf. 3.1.5. 3.4.10 Heavy duty adjustable yoke (option) Remove screw to set desired position, then tighten. Caution: Slighty untighten Caution: the screws without removing Remove followspot from stand to set yoke position.
  • Page 17: Flight-Case (Option)

    3.4.12 Flight-case (option) EN - 15 -...
  • Page 18: Operations

    4 Operations 4.1 Light intensity 4.1.1 Range • Dimming 100% 4.1.2 Control Remotely with DMX512-A protocol Locally via dimming control handle or top control Locally via Standalone mode (1169 & 1469) DMX512-A (1169TC & 1469TC) HTP mode (Highest Takes Precedence): Light output is the highest value of DMX512 command or local control Focus mode: when standby screen displayed, Push Exit or up arrow for 3 secs →...
  • Page 19: Master Control

    4.1.3.3 Master control In order to supervise the operator from the console, master control DMX channel can be used. This channel limits the maximum value of the dimmer shutter. By using this function, it is possible to obtain synchronised fades with several spots or to give intensity limits (minimum and maximum) to the operator .
  • Page 20: Strobe

    4.2 Strobe 4.2.1 Range Strobe duration 255 = 20ms 0 = OFF 1 = 1ms Strobe speed 0 = 0.1Hz 255 = 10Hz 4.2.2 Control T Remotely with DMX512-A / Art-Net / sACN protocols. Mode 3 – 4 DMX512-A 4.3 Response time 4.3.1 Range X ms DMX 0 = 0 ms...
  • Page 21: Beam Size Adjustment

    4.4 Beam size adjustment 4.4.1 Range Beam angle Field angle Model Angles Minimum angle Maximum angle Beam angle 6.9° 13.4° OZ 1169 Field angle 7.1° 13.8° Model Angles Minimum angle Maximum angle Beam angle 12.9° 20.6° ALICE 1469 Field angle 13.2°...
  • Page 22: Pan / Tilt

    4.5 Pan / Tilt 4.5.1 Range Function Range 0 —> 360° TILT 35° 45° 37° 15° Yoke option, Yoke option, 50° position #1 position #5 65° 4.5.2 Control Lock Unlock EN - 20 -...
  • Page 23: Iris

    4.6 Iris 4.6.1 Range • Irising 100% Closed iris 4.6.2 Control TC models only 4.7 Gobo 4.7.1 Range Type Standard gobo - A size Ø100 mm Ø72 mm • Metal Dimensions Maximum • Glass image size Installation Cf. section: 3.4.4 4.7.2 Control EN - 21 -...
  • Page 24: Colour

    4.8 Colour 4.8.1 Range Type Coloured gel filter Ø210 mm Dimension Cf. section: 3.4.2 & section 3.4.3 Installation Place dark colours towards the front end. 4.8.2 Control Push / Pull Unlock = release colours Colour engaged EN - 22 -...
  • Page 25: Frost And Correction Filters

    4.9 Frost and correction filters 4.9.1 Range Type Frost or CTO glass Ø97 mm Dimension Installation Cf. section: 3.4.6 4.9.2 Control Frost glass Spare filter EN - 23 -...
  • Page 26: Horizontal Chopper

    4.10 Horizontal chopper 4.10.1 Range Type Accessory option: PG80 chopper kit Dimension Ø80 mm Installation Cf. section: 3.4.8 4.10.2 Control EN - 24 -...
  • Page 27: Controls And Parameters

    5 Controls and parameters 5.1 Local display and controls 5.1.1 Display Function Exit the current menu option and/or go back Press for 3 secs to enter Focus mode Enter the current menu option and/or valid Scroll through menus and/or Increase data value Scroll through menus and/or Decrease data value Scroll through menus and/or Increase data value Scroll through menus and/or Decrease data value...
  • Page 28: Menu

    5.1.2 Menu DATA FACTORY STATUS SETUP BOOT MODE DEFAULT Reset to factory settings. Reboot the fixture. DISPLAY PROTOCOL • DMX • INTENSITY SELFTEST • ARTNET • AUTO OFF • SACN • DUAL • STANDALONE SYSTEM ID DATA SETUP • SERIAL NUMBER •...
  • Page 29: Parameters

    5.1.3 Parameters Selection in SETUP/DISPLAY MODE menu → Display Mode Description 000% Always ON Main display (home screen) always ON NODE MASTER SETUP DISPLAY INTENSITY Adjust the intensity of the screen Intensity Intensity : 4 To change value, press buttons : press OK Intensity Auto-Off...
  • Page 30: Dmx512 - A Remote Control

    5.2 DMX512 - A remote control 5.2.1 Protocol E1.11 – 2008, USITT DMX512-A 5.2.2 Configuration Set mode through web interface Set mode through RDM protocol Locally, through the local control compatible device 1 - Set DMX address 2 - Set personality mode (see 5.2.4. DMX chart) Data Mode Protocol Press OK...
  • Page 31: Parameters

    5.2.3 Parameters 5.2.3.1 DMX Hold T Set through RDM protocol, Web interface or local control DMX512-A If data not detected Hold last values Reset DMX values Default value (Standalone value) EN - 29 -...
  • Page 32: Dmx Chart

    5.2.4 DMX chart Mode 1: Mode 2: Mode 3: Mode 4: Mode 5: Mode 6: DMX Channel Dimmer8B Dimmer16B Profile8B Profile16b Followspot8b Followspot16b Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer fine Strobe duration Dimmer fine Master Dimmer fine Strobe speed Strobe duration Strobe duration Master...
  • Page 33: Rdm Remote Control

    5.3 RDM remote control 5.3.1 Protocol ANSI E1.20 – 2010 / ANSI E1.37 - 1 For more information about RDM protocol: http://www.rdmprotocol.org/ 5.3.2 Functions RDM COMPATIBILITY SULLY V2.7 VERSION Queued_ Description Standard Ack_Timer Message 4.00 Network Management DISCOVERY_UNIQUE_BRANCH E1.20 ✔ ✔ 00 01 DISCOVERY_MUTE E1.20...
  • Page 34 RDM COMPATIBILITY SULLY V2.7 SULLY Queued_ Description Standard Ack_Timer Message 4.00 Control IDENTIFY_DEVICE E1.20 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 10 00 RESET_DEVICE E1.20 ✔ ✔ ✔ ✔ ✔ ✔ 10 01 PERFORM_SELFTEST E1.20 ✔ ✔ ✔ ✔ ✔...
  • Page 35: Art-Net Remote Control

    5.4 Art-Net remote control 5.4.1 Protocol Artistic Licence Art-Net v3 & v4. For more information about Art-Net protocol: http://art-net.org.uk/ 5.4.2 Configuration Set mode through Web interface Locally, through the local control (see 5.7 Web interface) Ethernet connection 1 - If necessary, change IP settings 2 - Set Art-Net Universe 3 - Set DMX address 4 - Set personality mode (see 5.2.4.
  • Page 36: Local Set-Up

    5.4.3 Local set-up Caution: (*) Activate Art-Net in protocol mode beforehand. step 1 DATA MODE Data Mode step 2 Protocol Press OK Press OK DATA MODE STATUS SETUP FAC PROTOCOL PERSONALITY DMX ADDI Press OK to validate to validate to enter step 2 step 1 DATA MODE...
  • Page 37: Sacn Remote Control

    5.5 sACN remote control 5.5.1 Protocol ANSI E1.31 – 2009 sACN (Streaming-ACN) 5.5.2 Configuration Locally, through the local control Set mode through Web interface (see 5.7 Web interface) Ethernet connection 1 - If necessary, change IP settings 2 - Set sACN universe 3 - Set DMX address 4 - Set personality mode (see 5.2.4.
  • Page 38: Local Set-Up

    5.5.3 Local set-up Caution: (*) Activate sACN in protocol mode beforehand. step 1 DATA MODE Data Mode step 2 Protocol press OK press OK DATA MODE STATUS SETUP FAC PROTOCOL PERSONALITY DMX ADDI Press OK to validate to validate to enter step 2 step 1 DATA MODE...
  • Page 39: Dual Remote Control

    5.6 Dual remote control 5.6.1 Protocol Dual Mode: Available only on an Ethernet network It allows to send a DMX 512 signal through a Sacn data stream and at the same time to use an Artnet/ArtRdm data stream to control, set and monitor the equipment via RDM. This mode can be set by Web interface or the local control screen.
  • Page 40: Local Set-Up

    5.6.3 Local set-up Caution: (*) Activate sACN in protocol mode beforehand. step 1 DATA MODE Data Mode step 2 Protocol press OK press OK DATA MODE STATUS SETUP FAC PROTOCOL PERSONALITY DMX ADDI Press OK to validate to validate to enter step 2 step 1 DATA MODE...
  • Page 41: Web Interface

    5.7 Web interface 5.7.1 Control Ethernet connection The fixture must be connected to a compatible network or directly to a computer using an ethernet cable. 5.7.2 Default IP address By defaut : DHCP = OFF Address = 2.XXX.XXX.XXX Mask = 255.0.0.0 T If IP address unknown (due to a previous modification), a hard reset must be done (see 6.6 Factory defaults).
  • Page 42: Fan Cooling Modes

    5.8 Fan cooling modes 5.8.1 Range Modes Silent Normal Full < 40.5 dB(A) < 43.4 dB(A) < 45.8 dB(A) Cooling → → 100% Brightness 5.8.2 Control DMX512-A Remotely by DMX512-A Locally selection in → Mode 1 – 2 – 3 – 4 SETUP/COOLING 5.9 Gel Fan mode GEL FAN menu:...
  • Page 43: Service

    6 Service 6.1 Preventive maintenance 6.1.1 Frequency General maintenance should be performed at least once a year or more frequently if the equipment is operated in adverse conditions (smoke, heat, humidity, touring, etc.). 6.1.2 General cleaning Remove dust from the unit. Front glasses can be cleaned with solutions containing alcohol.
  • Page 44: Inner Fans & Led Glass Protection Cleaning

    6.1.6 Inner fans & LED glass protection cleaning Only use solutions containing alcohol to clean inner parts. Inner fans & LED access Caution: DISCONNECT the fan wire before removing the LED housing cover. Caution: DO NOT REMOVE the screws on the lower part of the LED housing.
  • Page 45: Local Potentiometer

    6.3 Local potentiometer → selection in SETUP / LOCAL POTENTIOMETER (LOCAL POT) Function Parameters Description (1169 & 1469) Setup Disable SETUP LOCAL POT SETUP LOCAL POT SETUP Setup Enable Disable SETUP ROTATION CALIBRATION Press OK to validate Enable (1169TC & 1469TC) Rotation Normal (CW): Clockwise...
  • Page 46: Electronic Thermal Management System

    6.4 Electronic thermal management system In case of overheating, light intensity will be reduced by the system. Power reduction and temperature values are available by using a RDM protocol compatible device. 6.5 Firmware update 1. Firmware available on www.robertjuliat.com//followspots -> Alice or Oz 2.
  • Page 47: Selftest

    6.7 Selftest Select SELFTEST in the main menu : There are 9 tests available that will be performed by the fixture. STATUS At the end of each test, a PASS/FAIL message will be displayed. SELFTEST Press OK SELFTEST SYSTEM ID LIGHT SOUP to start SELFTEST...
  • Page 48 DMX Test DMX IN DMX data is required to complete this test. DMX IN fail or NO DMX DMX OUT Plug DMX OUT then press OK DMX OUT DMX OUT fail or NO DMX Signal Leds Test LEDS green LEDS blue LEDS Test Report...

This manual is also suitable for:

Oz seriesOz 1169tcAlice 1469tcOz 1169Alice 1469

Table of Contents