eltherm ELTC-41 Operation Manual

Temperature controller up to 999c for front installation
Hide thumbs Also See for ELTC-41:

Advertisement

Quick Links

OPERATION-
Temperature controller up to 999°C
eltherm GmbH
Ernst-Heinkel-Strasse 6 -10
57299 Burbach, Germany
MANUAL
ELTC-41 and ELTC-42
for front installation
P.: +49 2736 4413-0
F.: +49 2736 4413-50
info@eltherm.com
BU-106
Revision 7
www.eltherm.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELTC-41 and is the answer not in the manual?

Questions and answers

Summary of Contents for eltherm ELTC-41

  • Page 1 OPERATION- MANUAL ELTC-41 and ELTC-42 Temperature controller up to 999°C for front installation eltherm GmbH P.: +49 2736 4413-0 BU-106 F.: +49 2736 4413-50 Ernst-Heinkel-Strasse 6 -10 Revision 7 57299 Burbach, Germany info@eltherm.com www.eltherm.com...
  • Page 2: Table Of Contents

    For safety components and systems, the assembly instructions as well as the relevant and currently valid standards and regulations must be observed. eltherm GmbH Document: Operation manual ELTC-41 and ELTC-42 Temperature control- 864305062004X Ernst-Heinkel-Str. 6-10 BU-106 ler up to 99°C for front installtion 57299 Burbach T.: +49 2736 4413-0...
  • Page 3: Introduction

    If it is not avoided, there is a risk of injury or at least a high risk of ronmentally sound use. damage. For proper and safe use of the ELTC-41 and STORAGE ELTC-42 temperature controller, please follow these instructions.
  • Page 4: Functional Description & Technical Data

    FUNCTIONAL DESCRIPTION & TECHNICAL DATA TECHNICAL DATA Controller type ELTC-41 (0620041) ELTC-42 (0620042) Nominal voltage 90…260 VAC, 50/60 Hz 24 VDC ± 10 %, 22...28 VAC Power consumption max. 5 W max. 100 mA Relays K1 12 A res. resp. AC1/max. 240 VAC 12 A res.
  • Page 5: Functional Description

    K2 / Alarm 22..28 VAC Imax 100 mA Tmax 55°C 1 2 3 4 5 6 7 4 5 6 7 1 2 3 90..260 VAC 50..60 Hz Pmax 5 W Tmax 55°C Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 6: Operating Mdoes

    OPERATING MODES The 2 temperature-inputs enable the following operation-modes of K2: as alarm-enabling- or check-back relay dependent on K1. (P11=1; P21=5; P35=0…5; input F1 linked to K1 and to K2) as overtemperature protection with fixed set-point 2 or as second independent controller. Load to be switched by separate contactor.
  • Page 7: Operation

    " " = Decrease values "P" = Programming key After switching on, the type number ("C41" for ELTC-41 and Protection against unauthorized operation "C42" for ELTC-42) and software version of the device appear The control setpoints can basically be set without restriction, and after approx.
  • Page 8: Parameters And Their Meaning

    PARAMETERS AND THEIR MEANING In [...] the factory settings are indicated. Parameter Meaning and range Parameter Meaning and range Range 0/2...10K, [2K] display only Actual value sensor 1 Switching hysteresis 2 (0=0,5K for Pt100) of P20 (2=2K for thermocouple) display only Actual value sensor 2 Min.
  • Page 9: Notes On Commissioning

    We declare that the described product fully complies with Di- 0…65534 hrs. rectives 2014/35/EU, 2014/30/EU and 2011/65/EU. If you need Working hours relay K2 a detailed declaration of conformity, please contact us. Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 10: Modbus

    Object ID = 0x00 Read input register HINWEIS all temperature values are with resolution 1K Function = 0x04 HiByte Hardware ID: 41 (for ELTC-41/42) Communication setting is N,8,2 (None parity, 8 data bits, Address = 0 LowByte Param.-list ID: 3 (for version 03)
  • Page 11: Modbus-Parameterslist

    Operation manual BU-106 ELTC-41 & ELTC-42 Revision7 Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 12 Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...

This manual is also suitable for:

Eltc-42

Table of Contents