OPERATION-
Temperature controller up to 999°C
eltherm GmbH
Ernst-Heinkel-Strasse 6 -10
57299 Burbach, Germany
MANUAL
ELTC/L-15
with ramp mode
as tabletop unit
P.: +49 2736 4413-0
F.: +49 2736 4413-50
info@eltherm.com
BU-108
Revision 1
www.eltherm.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELTC/L-15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for eltherm ELTC/L-15

  • Page 1 OPERATION- MANUAL ELTC/L-15 Temperature controller up to 999°C with ramp mode as tabletop unit eltherm GmbH P.: +49 2736 4413-0 BU-108 F.: +49 2736 4413-50 Ernst-Heinkel-Strasse 6 -10 Revision 1 57299 Burbach, Germany info@eltherm.com www.eltherm.com...
  • Page 2: Table Of Contents

    Notes on commissioning RAMP MODES Declaration of Conformity NOTES DOWNLOADS For proper and safe use of the ELTC/L-15 temperature cont- roller, please follow these instructions. Please keep these instructions for future reference (e.g. in the system documentation). RESERVATION Subject to technical changes. Changes, errors and misprints do not constitute grounds for claims for damages.
  • Page 3: Introduction

    For more information on the disposal and recovery of waste electrical and electronic equipment (WEEE) and collection points, please contact your local waste management com- pany or the manufacturer from whom you purchased the product. Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 4: Functional Description & Technical Data

    If the actual value (P01) falls below the setpoint (P10 minus hysteresis P11), relay K1 switches the heating on. In the event of sensor errors, relay K1 switches the heating line off or on, depending on the configuration of the controller. TECHNICAL DATA ELTC/L-15 (Art. 0621501) Nominal voltage 90…260 VAC, 50/60 Hz...
  • Page 5: Connection Plan

    NOTE After switching on the controller, the display shows the current actual value. Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 6: Operation

    OPERATION OPERATING PANEL LEDs in Display "1" = Control relay ON "2" = Ramp ON "4" = Alarm relay activated (=switched OFF) A flashing of the LEDs indicates a function delay. Keys " " = Increase values " " = Decrease values "P"...
  • Page 7: Parameters And Their Meaning

    Ramp setpoint 1 Nop=inactive 1..999 Min., [30 Min], Time for rampe 1 Nop, 0...950°C [100°C] Ramp setpoint 2 1..999 Min., [30 Min], Time for rampe 2 Nop, 0...950°C [100°C] Ramp setpoint 3 Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 8: Notes On Commissioning

    RAMP MODES Notes on commissioning ATTENTION Ramp start The settings of the controller must be checked during Press the „ " key for >5 seconds, LED „2“ lights up continuous- commissioning. ly.If the current temperature is below the value stored for P50, it is first heated up to this value.
  • Page 9: Declaration Of Conformity

    Parameter Own settings Declaration of Conformity We declare that the described product fully complies with Di- rectives 2014/35/EU, 2014/30/EU and 2011/65/EU. If you need a detailed declaration of conformity, please contact us. Contact us: +49 2736 4413-0 • info@eltherm.com www.eltherm.com...
  • Page 10: Downloads

    DOWNLOADS You can find helpful downloads for this or other products under the following link: https://eltherm.com/downloads eltherm GmbH Headquarters Ernst-Heinkel-Straße 6 -10 57299 Burbach, Germany T.: +49 2736 4413-0 F.: +49 2736 4413-50 info@eltherm.com www.eltherm.com...