5. PERFORMANCE

The performance of the pump depends on the orientation of the solar panel to the sun and its intensity. The maxi-
mum data is achieved under optimum conditions. Operation in the shade or on cloudy days cannot be guaranteed.
The solar pond sets are primarily designed for use in the summer months. However, the solar panel output should
also be sufficient for operation on days in spring and autumn with excellent sunlight. However, this cannot be
guaranteed.
For models with battery operation, the function of the solar pond set depends on the charge status of the batteries.

6. SECURITY TIPS

l Obey absolutely valid regulations on the electrical security
l Never run pump dry
l Pumping inflammable, as well as all other aggressive liquids is prohibited
l Pay attention to the medium max. 40°C
l Any altering of the product itself or changing of the components is forbidden.
l With longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
l Do not connect the pump to any AC voltage power directly, it's ONLY for DC Voltage power.
l Operate the pump in freshwater or saltwater only (never above 50°C), especially keep it away from flammable liquids.
l All solar panels are very sensitive, protect it before all against external mechanical influences (shock, vibration, etc.)
The manufacturer explains:
l To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the
instructionsin this book.
l To reject every responsibility for the damages which originate from the improper use of the pump.

7. SERVICING

If after some time the pump starts losing power or stops working, please clean up sediment in the pump shell or
filter cribs. Kindly note the pump can be opened by pressing down at the bottom of the filter housing. To clear the
impeller, open the pump housing at the front by sliding up the front plastic cover.
For models: Oasis 200-1
Rügen 120-1
The solar module should only be cleaned
with soft tissue or propriety glass
cleaning solution.
Pull off filter cover as shown
Open impeller cover, then
impeller can be easily removed
Remove filter and rinse in water
Rinse all parts thoroughly in water