Alemite 8427 Service Manual

Alemite 8427 Service Manual

Submersible pump

Advertisement

Quick Links

Description

Submersible multistage pumps with 2, 3 or 4 impellers to
give a great range of pressures to suit many different applica-
tions. Particularly suitable for pumping 34% UREA solution
(Diesel Exhaust Fluid) supply from totes or below ground
Storage tanks.
WARNING
!
Read this documentation carefully before installa-
tion. Installation and functioning must comply with
the safety regulations in the country in which the
product is installed.
Failure to comply with the safety regulations not only
causes risk to personal safety and damage to the
equipment, but invalidates every right to assistance
under guarantee
Technical Data
Pump Model
No. of Impellers
H.P.
Supply Voltage
Absorbed power
Delivery (GPM)
Head Up to (ft.)
Motor protection
Thermal Class
Max. operating press (psi)
Liquid temp. range
Max. immersion (ft.)
Storage temp
Relative air humidity
671034
Service Guide
Submersible Pump
8427
8428
2
3
1/2
3/4
115V ; 60Hz
see electrical data plate
2 to 25
79
118
IP68
F
35
52
33 °F to 90°F
33
33 °F to 90°F
Max 99%
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
Copyright © 2012 by Alemite, LLC
This document contains confi dential information that is the property of Alemite, LLC
and is not to be copied, used, or disclosed to others without express written permission.
Figure 1 Model 8427 DEF Pump
It is advisable that installation be carried out by
skilled personnel in possession of the technical qual-
ifi cations required by the specifi c legislation in force.
8429
The term skilled personnel means persons whose
4
training, experience and instruction, as well as their
1
knowledge of the respective standards and require-
ments for accident prevention and working condi-
tions, have been approved by the person in charge of
plant safety, authorizing them to perform all the nec-
essary activities, during which they are able to recog-
157
nize and avoid all dangers.
Use is allowed only if the electric system is in pos-
64
session of safety precautions in accordance with the
regulations in force in the country where the product
is installed.
The pump should not be handled while connected to
an electrical supply.
Alemite, LLC
WARNING
!
!
WARNING
8427
8428
8429
SER 8427
Revision (4-12)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8427 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alemite 8427

  • Page 1 Copyright © 2012 by Alemite, LLC SER 8427 This document contains confi dential information that is the property of Alemite, LLC 671034 and is not to be copied, used, or disclosed to others without express written permission. Revision (4-12)
  • Page 2 SER 8427 1/2” Submersible Pump Figure 2 8427 - Typical below ground installation Alemite Pump Model 8427 Water Tight chamber DEF Dispenser Control panel for dry run protection with pump relay Level control sensor Tank air vent External air vent...
  • Page 3 1/2” Submersible Pump SER 8427 Before Installation Before installing the pump you must check that the rotat- ing parts turn freely. For this purpose remove the black bung (Pos. No. 18) from the base of the pump (Pos. No. 20) Fig. A Insert a fl...
  • Page 4 All electrical work should be performed by a qualifi ed The suction fi lter in Alemite pumps must always be pres- electrician in accordance with the latest edition of the ent during pump operation.
  • Page 5 1/2” Submersible Pump SER 8427 Maintenance approved by the manufacturer so as to be able to guarantee maximum safety of the machines and systems in which they may be fi tted. In normal operation, the pump does not require any spe- Before starting, ensure that the pump is not connected to cifi...

This manual is also suitable for:

84288429

Table of Contents