IDEAL 61-744 Instruction Manual page 11

600 aac clamp meter
Hide thumbs Also See for 61-744:
Table of Contents

Advertisement

Available languages

Available languages

Temperature Coefficient: 0.1 times the applicable accuracy specification per
degree C from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and 82°F to 122°F)
Function
40.00A//400.0A/600A (50Hz - 60Hz)
AC Current*
40.00A/400.0A/600A (60Hz - 400Hz)
400.0V
AC Voltage
600V
DC Voltage 400.0V/600V
400.0Ω/4.000kΩ/40.00kΩ/
400.0k Ω
Resistance
4.000MΩ
40.00MΩ
Audible indication < 25Ω
Continuity
Response time: 500ms
* Accuracy stated for crest factor ≤ 3
Input Impedance is 10MΩ.
Range and
Resolution
(50Hz - 500Hz)
(50Hz - 500Hz)
Accuracy
61-744
61-746
1.7% + 6 digits
1.7% + 10 digits
3.0% + 6 digits
3.0% + 10 digits
1.2% + 5 digits
1.2% + 8 digits
1.5% + 5 digits
1.5% + 8 digits
0.5% + 2 digits
1.0% + 4 digits
1.5% + 4 digits
3.0% + 5 digits
N/A
Overload
Protection
600AAC
600 VDC or AC rms
600 VDC or AC rms
600 VDC or AC rms
600 VDC or AC rms
Page 11

Advertisement

Table of Contents
loading

This manual is also suitable for:

61-746

Table of Contents