HP 9800 Series Service Manual page 87

Aexible disc memory
Hide thumbs Also See for 9800 Series:
Table of Contents

Advertisement

A·40 HP 9895A Disc Memory Command Set
HP-IB Sequence:
ATN
(OIADDRS
I
Primary
Listen
ATN
I
PIO~DDRSI
Primary
Talk
Status:
Cold Load Read Request
ATN
EOI
P
P
Pll01000
P
I Secondary
I
D
00000
Opcode
I I
HHSSSSSS
P
Head / sectoJ
E
Where:
ATN
I PIIOOOOO
Secondary
I
HH
- Head address
SSSSSS - Sector address
Send Data
P
P
D
+-
Data Bytes .-
No errors.
Sl
-0
Stat 2 - Type field updated.
DSJ
-0
Unsuccessful read.
Sl
- Error
EOI
P
P
E
Stat 2 - Bits A, E and C set, if appropriate.
DSJ
-0
ATN
I
POlllll1
1
Unlisten
ATN
I PIOll1llI
Untalk
Requirements for Execution:
1. Unit available,
Parallel Poll:
2. Disc ready,
3. Disc of known format,
4. Valid head and sector number.
If less than the specified number of bytes is accepted by the
HP-IB controller, the parallel poll response will be re-
enabled by the Untalk command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

9895a

Table of Contents