E38
The analogue pressure switch is not able to measure any variation in the water level for at
Checks to perform:
Run the diagnostic
cycle and set phase
6.
Is the motor running
and the drum not
moving?
Y
E
S
place/reposition the
belt and repeat the
diagnostic cycle to
check for any further
alarms.
Fig. 8
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x

E38: Internal pressure chamber is clogged

least 30 secs during drum rotation.
Check that all the connectors are inserted correctly
Drain the water from
the tub and check
the internal pressure
chamber and the
NO
pressure switch
Is the system free of
obstructions?
–(see fig.2 )-
Replace the
analogue pressure
switch and repeat
the diagnostic cycle
to check for any
further alarms.
Fig. 2
NO
hose.
Y
E
S
If there are burns on the circuit board,
31/67
E38
Clean the internal
pressure chamber
and/or the pressure
switch hose
(disconnect the
hose and blow into it
to make sure the
system is free of
obstructions) .
–(see fig. 8)-
Repeat the
diagnostic cycle to
check for any further
alarms.
see page 65
599 72 97-24