E35: Water Level Too High - Electrolux EWM0931 Series Service Manual

Table of Contents

Advertisement

E35
The main circuit board measures a water level, using the electronic pressure
Checks to perform:
Drain the water from the tub.
Are the pressure switch hose and
pressure chamber free of obstructions?
(disconnect the hoses and blow into
them to make sure
the system is free of obstructions)
–(see fig.2 and 8)-
Y
E
S
Does the
appliance continue
to fill with water
NO
even when it is
switched off?
Y
E
S
\\\
Replace
the water fill
solenoid valve
and repeat the
diagnostic cycle
to check for any
further alarms.
Fig. 2
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x

E35: Water level too high

switch, of more than 300 mm for longer than 15 secs.
Check that all the connectors are inserted correctly
Run the
diagnostic cycle
at phase 8.
Once the door
has locked, does
the appliance
start to fill with
water?
Y
E
S
Replace the main
PCB and repeat
the diagnostic
cycle to check for
any further
alarms.
Clean/change the hose and/or the
pressure chamber and repeat the
NO
diagnostic cycle completely to check for
Is the wiring
between the main
PCB and the
analogue
NO
pressure switch
connected
correctly on both
sides?
Y
E
S
Change the
analogue
pressure switch
and repeat the
diagnostic cycle
to check for any
further alarms.
Fig. 8
If there are burns on the circuit board,
30/67
any further alarms.
Reconnect
and/or replace
the wiring and
repeat the
NO
diagnostic cycle
to check for any
further alarms.
see page 65
E35