INSTALLATION TYPES

This microwave oven is designed for adaptation
to the following three types of ventilation:
A. Recirculating (Non-Vented Ductless)
B. Outside Back Exhaust (Horizontal Duct)
C. Outside Top Exhaust (Vertical Duct)
RECIRCULATING
A
(NON-VENTED DUCTLESS)
See page 10
Models are shipped
for recirculating
exhaust. Some
models have a
disposable charcoal
filter installed to help
remove smoke and
odors.
NOTE: Read the pages 14-15 only if you plan to vent your exhaust to the outside. If you
plan to recirculate the air back into the room, proceed to page 10.
Installation Instructions
EN-9
(Choose A, B or C)
NOTE: This microwave is shipped assembled
for Recirculating. Select the type of
ventilation required for your installation and
proceed to that section.
OUTSIDE BACK EXHAUST
B
(HORIZONTAL DUCT)
See page 16
OUTSIDE TOP EXHAUST
C
(VERTICAL DUCT)
See page 20
Adaptor Must Be
Moved to the
Back for Outside
Back Exhaust
Adaptor in
Place for
Outside Top
Exhaust