RECIRCULATING
A
INSTALLATION OVERVIEW
A1. Attach Mounting Plate to Wall
Prepare Top Cabinet
A2.
Check Blower Plate
A3.
Mount the Microwave Oven
A4.
Install or change Charcoal
A5.
Filter
IMPORTANT NOTES:
Make sure the screws for the blower motor and
blower plate are securely tightened when they
are reinstalled. This will help to prevent
excessive vibration.
Make sure the motor wiring has been properly
routed and secured, and that the wires are not
pinched.
A1.
ATTACH THE MOUNTING
PLATE TO THE WALL
Attach the plate to the wall using toggle
bolts. At least one wood screw must be
used to attach the plate to a wall stud.
NOTE: If the cabinet depth including the cabinet
doors is more than 13"then the unit must be
spaced out from wall using adequate materials
supporting 150 Ibs to allow proper top vent air
exhaust/intake.
13" MAX.
(33 cm)
Cabinet
Installation Instructions
(Non-Vented Ductless)
Cabinet
EN-10
3/8" TO EDGE
along the dotted line.
Trim the rear wall template
12"
NOTE: IT IS VERY IMPORTANT
TO
READ AND FOLLOW
THE DIRECTIONS
IN THE INSTALLATION
INSTRUCTIONS
WITH THIS
BEFORE PROCEEDING
REAR WALL TEMPLATE.
serves to position the bottom
4"
This Rear Wall Template
the horizontal exhaust
mounting plate and to locate
outlet.
that the template is positioned
1. Use a level to check
2. Locate and mark at least
accurately.
one stud on the left or
right side of the centerline.
It is important to use at
least one wood
screw mounted firmly in
two additional, evenly spaced
a stud to support the weight
of the microwave. Mark
locations for the supplied
toggle bolts.
locations. Where there
is
3. Drill holes in the marked
for wood screws. For holes
that do not line up with
a stud, drill a 3/16" hole
a stud, drill 5/8" holes for
toggle bolts.
DO NOT INSTALL THE
MOUNTING PLATE
AT THIS TIME.
4. Remove the template
from the rear wall.
5. Revie
w
h t
e Installation Instruction
book for your
installation situation.
Darle vuelta a la hoja
para consultar la
versión en Español.
Locate and mark holes
to align with holes in the
mounting plate.
IMPORTANT:
STUD ON EITHER SIDE
OF
LOCATE AT LEAST ONE
THE CENTERLINE.
FOR 2 ADDITIONAL,
EVENLY
MARK THE LOCATION
PLATE
SPACED TOGGLE BOLTS
IN THE MOUNTING
to align with holes in the
AREA.
Locate and mark holes
m
o
t n
u
n i
g
l p
t a
. e
IMPORTANT:
STUD ON EITHER SIDE
OF
LOCATE AT LEAST ONE
THE CENTERLINE.
MARK THE LOCATION
FOR 2 ADDITIONAL,
EVENLY
along the dotted line.
IN THE MOUNTING PLATE
Trim the rear wall template
SPACED TOGGLE BOLTS
AREA.
1
Remove the toggle wings from the bolts.
Insert the bolts into the mounting plate
2
through the holes designated to go into
drywall and reattach the toggle wings to
" (19 mm) onto each bolt.
3
4
To use toggle bolts:
Spacing for
Toggles More
Than Wall
Thickness
Toggle Wings
Mounting
Toggle
Plate
Bolt
Wall
3
Place the mounting plate against the wall
and insert the toggle wings into the holes
in the wall to mount the plate.
NOTE: Before tightening toggle bolts and wood
screw, make sure the bottom of the mounting
plate touch the bottom of the cabinet when
pushed flush against the wall and that the plate
is properly centered under the cabinet.
CAUTION: Be careful to avoid pinching fingers
between the back of the mounting plate and the
wall.
Tighten all bolts. Pull the plate away from
4
the wall to help tighten the bolts.
Bolt End