NO
POSSIBLE CAUSE
18
Reverse Controller (Only for HSRX Controls fitted with "Neutral Detent and Engine Start Interlock").
Engine can be started with either "For-
ward" or "Reverse" selected on the
Reverse Controller.
19
No hydraulic pressure from the Jet Hydraulic Pump Unit (Saginaw Pump).
Reverse Cylinder is not functioning due
to little or no hydraulic pressure from
the Saginaw Pump.
Table 6: Reverse System Faults
SYMPTOMS
Adjust the "Neutral Detent and Engine
Start Interlock" microswitch in accord-
ance with the manufacturers instructions.
Increase the Engine (Jet) revolutions in
quick bursts to about 1500 RPM until the
vanes in the Saginaw Pump become freed.
(This may cure the problem).