The equipment is not designed for installation in
laundries.
The equipment must be positioned in such a way
that the mains plug is accessible at all times.
The temperature in the cooling circuit may
become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the "Sleep"
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.

2. Items supplied

1 indoor device (box 1, art. no. 23.653.96)
1 outdoor device (box 2, art. no. 23.653.97)
1 set of installation accessories (for details,
see page 15)
27.02.2008
15:26 Uhr
Seite 9

3. Technical data

Cooling capacity
Heating capacity
Energy efficiency
Air capacity
Absorbed humidity (30°C/80% RH)
Timer
Operating voltage
Socket fusing
Nominal power consumption, cooling
Nominal current consumption, cooling
Nominal power consumption, heating
Nominal current consumption, heating
Compressor
Compressor starting current
Outdoor temperature
Indoor temperature
Fluid line Ø A
Suction pipe Ø A
Length of refrigerant line supplied
Length of refrigerant line, max.
Max. difference in height between indoor/outdoor
device
Refrigerant
Refrigerant filling capacity
Refrigerant refill quantity from 5 m
Sound pressure level
Inside
Outside
Dimensions
Inside
Outside
Weight
Inside
Outside
Note:
The specified capacities and performances are
based on the following conditions (EN 14511):
Cooling:
Air temperature at the inlet on the indoor device:
27°C for dry thermometer bulb (DB), 19°C for wet
thermometer bulb (WB). Outdoor air temperature:
35°C for dry thermometer bulb (DB), 24°C for wet
thermometer bulb (WB).
GB
2500 watts
- watts
D (EER 2.62)
420 m
3
/h
1.0 l/h
24 h
230 V ~ 50 Hz
10 A
1150 watts
4.6 A
- watts
- A
Rotary piston
23 A
-15 - +46°C
+16 - + 30°C
6.35 mm
9.53 mm
4 m
10 m
5 m
R 407 C
500 g
20 g/m
≤ 37 dB (A)
≤ 52 dB (A)
71 x 18 x 25 cm
72 x 26 x 43 cm
7 kg
25 kg
9