Advertisement

Quick Links

Anleitung_Split_850_C_GB:_
t Operating Instructions for the
Indoor and Outdoor Device
Split-system Air Conditioner
Important note:
This high-quality product will only offer
optimum service if installed correctly and in
the right place, and is put into operation for
the first time by a suitably competent person.
Avoid malfunctions by seeking competent
advice from an expert with regards to the
location, installation and starting up of the
system.
We shall accept no liability for malfunctions
or inadequate cooling performance resulting
from the improper handling of the product.
Only a suitably qualified firm is permitted to
undertake any work of making the electrical
and cooling system connections and putting
the system into operation for the first time.
If the system is to be moved to another
location or disposed of, only a suitably
qualified electricianʼs/cooling system firm is
permitted to undertake any work of
disassembly or disposal.
Art.-Nr.: 23.651.66
27.02.2008
15:25 Uhr
Seite 1
I.-Nr.: 01028
850 C
SPLIT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 23.651.66 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ProKlima 23.651.66

  • Page 1 If the system is to be moved to another location or disposed of, only a suitably qualified electricianʼs/cooling system firm is permitted to undertake any work of disassembly or disposal. 850 C SPLIT Art.-Nr.: 23.651.66 I.-Nr.: 01028...
  • Page 2 Anleitung_Split_850_C_GB:_ 27.02.2008 15:25 Uhr Seite 2...
  • Page 3 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 3...
  • Page 4 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 4 > 150 mm > 150 mm Ø 65 Ø 65...
  • Page 5 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 5...
  • Page 6 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 6...
  • Page 7: Table Of Contents

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 7 Table of contents For the user and expert 1. Safety regulations 2. Items supplied 3. Technical data 4. Intended use 5. Description of parts 6. Remote control display 7. Setting up the remote control 8.
  • Page 8: Safety Regulations

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 8 Never use combustible cleaning agents as these Important! could cause a fire or deformation. When using the equipment, a few safety precautions If the air conditioner is to be used in conjunction must be observed to avoid injuries and damage. with other heaters, the air should be refreshed Please read the complete operating instructions and periodically, otherwise there is a risk of lack of...
  • Page 9: Items Supplied

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 9 The equipment is not designed for installation in 3. Technical data laundries. The equipment must be positioned in such a way Cooling capacity 2500 watts that the mains plug is accessible at all times. Heating capacity - watts The temperature in the cooling circuit may...
  • Page 10: Intended Use

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 10 Temperature ranges: Horizontal air flow grille Vertical air slit Cooling Remote control Room temperature 16°C ~ 30°C Refrigerant line, condensate hose Outdoor temperature > +18°C Air inlet 10 Air outlet Dehumidifying Room temperature 16°C ~ 30°C Outdoor temperature >...
  • Page 11: Description Of The Remote Control Functions

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 11 receiver which can impede reception of the signal 13. LIGHT: - must be avoided. Handle the remote control with care. Do not drop it, keep it away from heat and Operating modes moisture so as not to damage the remote control. A) Cooling mode 1.
  • Page 12: Indoor Device Settings

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 12 3. Press the “Swing” key. The air flow is adjusted display from °C to °F or vice versa. upwards/downwards. Press the key twice to lock the slats in their current position. 4. Press the “FAN” key to select the fan speed: 9.
  • Page 13: General Notes

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 13 the panel audibly clicks into position in its open the compressor will not cut in until after a delay position (Fig. 7). of three minutes. 2. Raise the air filter slightly using the handle (Fig. 8) to take the filter out of the filter holder and 2.
  • Page 14 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 14 The device does not provide satisfactory cooling! Check the following: 1. Has an appropriate temperature been set? 2. Is the air filter soiled? Clean and fit back in place. 3. Are the inlets and outlets on the outdoor device blocked? 4.
  • Page 15: Installation Accessories

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 15 The following pages are intended for circuits. Select a suitably large cable cross-section. The yellow/green wire is to be used as a protective professional installers. conductor only and under no circumstances as a voltage carrying conductor. The fixed electrical Important connection of the device must be capable of being Do not hesitate to contact our service partners.
  • Page 16 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 16 4. The location must be sufficiently firm for you have completed the installation work. installation and the prevention of vibrations. Do not kink or compressed the refrigerant lines. 5. There must be no risk presented by combustible All the refrigerant lines, including connectors and gas or gas escaping as a result of corrosion.
  • Page 17 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 17 adhesive tape, checking that it is fully sealed as with the supplied protective tape. Depending on you do so. whether the lines are right-hand or left-hand versions, the corresponding bushing Important note: preparations must be removed from the indoor The following work must be carried out exclusively by device.
  • Page 18: Evacuation

    Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 18 D. Connecting the refrigerant lines 15. Evacuation Proceed as described in section B.5 to connect the refrigerant lines to the outdoor unit. Please read the The evacuation procedure may only be carried out following information carefully. by an authorized expert.
  • Page 19 2006/95/EG R&TTED 1999/5/EG 97/23/EG 2000/14/EG_2005/88/EG: 2004/108/EG 95/54/EG: 90/396/EWG 97/68/EG: 89/686/EWG EN 60335-1+A11;EN 60335-2-40; EN 50366; EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3 Landau/Isar, den 25.02.2008 Weichselgartner General-Manager Product-Management Art.-Nr.: 23.651.66 I.-Nr.: 01028 Archivierung: 2365165-13-4155050 Subject to change without notice...
  • Page 20 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 20 The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH. Technical changes subject to change...
  • Page 21 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 21 t For EU countries only Never place any electric tools in your household refuse. To comply with European Directive 2002/96/EC concerning old electric and electronic equipment and its implementation in national laws, old electric tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g.
  • Page 22 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 22...
  • Page 23 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 23...
  • Page 24 Anleitung_Split_850_C_GB:_ 27.02.2008 15:26 Uhr Seite 24 t GUARANTEE CERTIFICATE Dear Customer, All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card.

This manual is also suitable for:

Split 850 c

Table of Contents