Anleitung_Split_850_C_GB:_
GB
3. Press the "Swing" key. The air flow is adjusted
upwards/downwards. Press the key twice to lock
the slats in their current position.
4. Press the "FAN" key to select the fan speed:
Automatic -> Slow -> Medium -> Fast
5. Press the "+" or "-" key to set the desired
temperature.
6. Press the "Sleep" key to activate the sleep
function.
Notes!
If the cooling or dehumidifying mode is set in
conjunction with the sleep function, the set room
temperature increases (1°C during the first hour
and 2°C during the second hour) in order to
prevent overcooling.
E) Timer settings (for automatically switching the
device on/off)
Note:
First of all set the current time using the "Clock"
button.
1. "T-ON / Device ON timer button
This button enables you to switch on the unit
automatically (max. 24 hours). The only requirement
is that the device is connected to a power supply.
Press the "ON / OFF" button to deactivate the
"Device ON timer" again.
2. "T-OFF" / Device OFF timer button
This button enables you to switch off the unit
automatically (max. 24 hours). The only requirement
is that the unit is in operation. Press the "ON / OFF"
button to deactivate the "Device OFF timer" again.
F) Additional functions
BLOW function
This function prevents moisture forming on the heat
exchanger in the indoor unit.
TURBO function
An even higher fan speed will ensure that the
required room temperature is reached more quickly.
LOCK function
Press the "+" and "-" buttons at the same time to lock
and unlock the keypad on your remote control. As
soon as the keypad has been locked, a lock will
appear on the remote control display.
FAHRENHEIT / CELSIUS display
Press the "+" and "-" buttons at the same time whilst
the device is switched off to change the temperature
12
27.02.2008
15:26 Uhr
Seite 12
display from °C to °F or vice versa.

9. Indoor device settings

Setting the vertical air flow direction (Fig. 5)
The left-hand and right-hand side flow directions can
be adjusted manually. Perform these adjustments
before you start the device because once it has been
started the slats vibrate and there is a risk of your
fingers getting caught.
Remote control fails to work (emergency
operation) (Fig. 6)
If the remote control fails to work (empty batteries or
malfunction), use the emergency switch.
The device is off: After the emergency stop
switch has been pressed the device switches to
automatic mode. The slat adjuster also operates
in automatic mode.
The device is on: The device switches off if the
emergency switch is pressed.

10. Cleaning notes

Important!
Switch the device off and pull the mains plug each
time before cleaning.
Note!
The time intervals at which the device should be
cleaned are a factor of the area of installation. The
time intervals listed below should be maintained in
most cases.
Keep the outdoor device and the area around the
outdoor device clean. Regularly remove leaves, etc.
which can collect around the outdoor device.
Cleaning the housing of the indoor device
Clean the housing of the indoor device using
only a soft, wet cloth when necessary.
In order to avoid damaging the housing and
electronics, avoid the use of gasoline, thinners,
scouring powder, cleaners and the like when
cleaning.
Cleaning the air filters of the indoor device
Make sure that the air filters are clean! Soiled air
filters reduce the air output of the device. The air
filters of the indoor device should be checked and, if
necessary, cleaned on a monthly basis.
1. Raise the front panel of the indoor device until

Advertisement