Specifications - Nagano Keiki KH15-M Series Instruction Manual

Pressure transmitter
Table of Contents

Advertisement

4.

Specifications

Model number
Pressure sensor sealing type
Pressure range
*1
Maximum allowable pressure
Power-supply voltage
Output type
Accuracy
(Including linearity,
hysteresis, repeatability)
Operating temperature range
Storage temperature range
Temperature characteristics
Responsiveness
Liquid contact material
Screw size
Case structure
Weight
CE Marking
*3
UKCA Marking
*3
*1 : Model number KH15-M□6 and output type "0 to 5VDC" do not support the accuracy "± 0.25%F.S.".
*2 : However, in case of "0.1MPa or less", temperature range is 0 to 70℃.
Where temperature of the liquid contact area may reach 70℃ (in case of steam, hot water and etc.),
make sure the temperature does not exceed 70℃ by using pipe syphon , etc.
Where the temperature of the low-temperature fluid such as cold water is measured, take
countermeasures for dew condensation prevention.
*3: Before use, connect the product to an indoor power distribution network that is not affected by
lightning surge voltages and power system switching transients.
KH15-M□3
O ring type
0 to 0.1, 0 to 0.3, -0.1 to 0 MPa
-0.1 to 0.1 , -0.1 to 0.3 MPa
Twice as high as the pressure range
24VDC ± 10% or 12VDC ± 10%, 15 VDC± 10%(Only power-supply
4 to 20 mADC (Load resistance 500 Ω max.)
1 to 5VDC
0 to 5VDC
・ ± 1% F.S.
-20 to 70℃(No freezing nor condensation allowed)
-30 to 80℃(No freezing nor condensation allowed)
・ Where accuracy is " ± 0.25% F.S." => ± 0.025% F.S. /℃ (For both
zero point and span)
・ Where accuracy is "± 0.5% F.S." => ± 0.05% F.S. /℃ (For both zero
point and span)
・ Where accuracy is "± 1.0% F.S." => ± 0.1% F.S. /℃ (For both zero
point and span)
Diaphragm
: SUS630 (17-4PH)
Fitting
: SUS316
O ring
: NBR (Standard)
: EPDM
: Fluorine
: Chloroprene
G1 / 4B, G3 / 8B, G1 / 2B, R1 / 8, R1 / 4, R3 / 8, R1 / 2,
1 / 4 NPT, 3 / 8NPT, 1 / 2 NPT
(However, R screws and NPT screws are exclusively for the pressure range,
50 MPa or less)
Drip-proof type 2 (IP52)
Approx. 210 g (Including 2 m - cable)
EMC Directive
*3
, RoHS Directive
EMC SI 2016 No.1091
*3
, RoHS SI 2012 No.3032
TY-KH15-009A Ver. 3
KH15-M□4、M□6
Welding type
-0.1 to 0.5 => -0.1 to 2 MPa
0 to 0.5 => 0 to 100 MPa
Twice as high as the pressure range
(1.5 times high for 35,50MPa.
1.2 times high for 70,100MPa)
voltage can be selected)
(Load resistance10 kΩ min.)
(Load resistance 10 kΩ min.)
・ ± 0.25%F.S
(Pressure range: 3.5 to 20MPa)
・ ± 0.5%F.S.
(Pressure range: 0.5 to 50MPa)
・ ± 1.0% F.S
1 ms or shorter
KH15-M□4
Diaphragm : SUS630(17-4PH)
Fitting
KH15-M□6
Diaphragm : Co-Ni alloy
Fitting
3/ 10
.*1
*2
: SUS316
: SUS316

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kh15-m 3 seriesKh15-m 4 seriesKh15-m 6 seriesKh15-m

Table of Contents