e e e o o e WARNING!
ALWAYS VERIFY THAT THE MACHINE IS PROPERLY
GROUNDED TO AVOID ELECTRIC: SHOCK TO THE
WORK OPERATOR!
ee ooe
e CAUTION!'
• • • •
NEVER ATTEMPT TO CONNECT TO AN OUTLET WITH A
GREATER POWER SOURCE VOLTAGE THAN REQUIRED!
ELECTRICAL REQUIREMENTS
Before connecting the machine to the power source verify that the voltage supplied corresponds as specified on
the nameplate of the machine. A power source with greater voltage than needed can result In serious injury to the
user as well as damage the machine. If in doubt, contact a qualified electrician before connecting to the power
source.
GROUNDING
Machine must be properly grounded in order to avoid electric shock to the work operator.
Connect to а circuit breaker no greater than voltage supplied on name plate, to avoid shock or fire; replace the
power cord if it gets worn out, cut or damaged in any way replace immediately.
INSTALLATION
Fig. |
*
Make sure location is a fixed solid foundation. Verify that the
machine remains steady and properly balanced.
*
Choose work area accordingly, avoiding obstacles that may
interfere while work operations are being performed.
WARNING !
D
DISCONNECT THE MACHINE BEFORE PERFORMING ANY ADJUSTMENTS!
FAILURE TO COMPLY CAN CAUSE SERIOUS INJURIES TO THE MACHINE
AND THE WORK OPERATOR!
7
7
ADJUSTMENTS
MACHINE ANCHOR
Use two "L" type metallic plate locating in front and back of the
stand to fix machine on the floor. (Fig. 1)
EXTENSI
ES (Fig. 2
* — Install set screw(B) into extension table so that they are levelled
with the surface that faces the machine.
+
To attach the table extension to machine use hex head
bolts(A).
*
Find a straight edge approximately
four feet long to adjust
table extension.
+
Using bolts(A) and set screws(B), adjust so that when the straight
edge Is lying on the table extension, there is no space between
the straight edge and the table.
*
Tighten screw(A).
*
Repeate the same procedures for the opposite of table extension.
DJUSTME!
Fig.
3)
Turn handwheel (A) clockwise or counterclockwise to adjust to the
required height.