EDITION 05/2011
OPERATING MANUAL
5.1.5
EARTHING
Discharge of electrostatically charged components in atmospheres
containing solvents!
Explosion hazard from electrostatic sparks or flames
SIHI_0027_GB
Heavy paint mist if earthing is insufficient!
Risk of poisoning
Insufficient paint application quality
SIHI_0003_GB
Any material containers and the unit must be connected by a potential equalisation (earth)
cable.
5.2
PREPARATION OF PAINTS
The viscosity of the paints is of great importance. The best results are usually obtained with
paints between 80 and 260 milli Pascal x Sec (mPas).
Please also read the technical data sheet for the paint for optimal processing, viscosity
adjustment and intermixing of the material.
Part No. DOC394861
WARNING
Earth all unit components.
Earth the workpieces being painted.
WARNING
Earth all unit components.
Earth the workpieces being painted.
GM 4600AC