02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01
1
02PN8 HI-PE/PN-AS-600
02PN8 HI-PE/CN-AS
02PN7
METAL DETECTORS
02PN8 HI-PE/CN-AS-140
02PN8 HI-PE/CN-AS-140L
02PN8 HI-PE/PN-AS-600
02PN7
Installation and Maintenance
ATTENTION!
Keep the transducer matched with the electronics unit and the Technical Booklet having the same
serial number.
Program Version:
Rev.: FI 002 GB 60K10/16 v2_01 Date 2006-11-14
HI-PE v8_11 , 02PN7 V1_10

Advertisement

Table of Contents
loading

Summary of Contents for Ceia 02PN8 HI-PE/CN-AS-140

  • Page 1 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 02PN8 HI-PE/PN-AS-600 02PN8 HI-PE/CN-AS 02PN7 METAL DETECTORS 02PN8 HI-PE/CN-AS-140 02PN8 HI-PE/CN-AS-140L 02PN8 HI-PE/PN-AS-600 02PN7 Installation and Maintenance ATTENTION! Keep the transducer matched with the electronics unit and the Technical Booklet having the same serial number.
  • Page 2: Attention! Read These Instructions Before Working With The Device

    Warranty conditions The warranty on all CEIA products, extended to the period agreed with the Sales Department, is applicable to goods supplied from our factory, and for every constituent part thereof, with the exception of the batteries and the card reader.
  • Page 3: Table Of Contents

    Thank you for your kind interest and co-operation. CEIA reserves the right to make changes, at any moment and without notice, to the models (including programming), their accessories and optionals, to the prices and conditions of sale. Contents ATTENTION! READ THESE INSTRUCTIONS BEFORE WORKING WITH THE DEVICE ......2...
  • Page 4 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 IV - 02PN7 METAL DETECTOR - PROGRAMMING ..................20 ........................20 ONNECTION TO CONTROL TERMINAL ..............20 ONNECTION TO A CONTROL TERMINAL OR PERSONAL COMPUTER Connection ..............................20 Free access to programming phase (without password)................21 Access to the programming phase by means of the password ..............21 Execution of commands in remote programming ..................21 02PN7...
  • Page 5: Description

    The sensitivity of a other external devices. The security level may usually be good Metal Detector should be independent of the speed adjusted acting on sensitivity: CEIA’s Metal Detectors are of transit. also provided with a special command (IS) allowing the •...
  • Page 6: Construction Of The Metal Detector

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Construction of the Metal Detector The CEIA Metal Detectors described in this manual are most commonly used in airlock-type access cabins. They are made up of an electronics unit and an archway antenna;...
  • Page 7: 02Pn7: Accessories

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Table I-A: Antenna 02PN7 ø144 ø25 Rmin 40 640 - 760 Fig. I-5a: dimensions antenna: example of model with options 3 and 4 (see below) ø140 ø144 02PN7: Options Type of cable Anchoring ø20...
  • Page 8: 02Pn8 02Pn8 Hi-Pe

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Mains transformer Mains power-supply transformer, connectable directly to the electronics unit. Input voltage: 230 V~ or 115V~ Dimensions: 121 x 80 x 71 (LxWxH) Cable length plug side:: 2m Cable length electronics unit side: 2m Protection degree: IP30 (IEC529) Fig.
  • Page 9: Antenna

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Antenna The 02PN8 HI-PE antenna is available in various configurations as described below:: • 02PN8 HI-PE/PN-AS-600, panel model • 02PN8 HI-PE/CN-AS-140 , column model • 02PN8 HI-PE/CN-AS-140L , column model with extra-wide passageway Table I-B: 02PN8 HI-PE/PN-AS-600 ø10 L=3000...
  • Page 10: 02Pn8 Hi-Pe: Accessories

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Table I-C: 02PN8 HI-PE/CN-AS-140 e 02PN8 HI-PE/CN-AS-140L ø144 ø25 Rmin 40 Model | 02PN8 HI-PE/CN-AS-140 | 02PN8 HI-PE/CN-AS-140L 640 - 740 740 - 900 Fig. I-10a: antenna dimensions: example of model with options 2, 3, and 5 (see below) ø140...
  • Page 11: Installation

    INSTALLATION Before proceeding to install the device read the warnings and instructions in this section carefully. Please note that CEIA is not responsible for any damage that may result from installations that do not follow these guidelines. General installation notes Unpacking the Metal Detector Handle the material with care during unpacking operations.
  • Page 12: Electromagnetic Compatibility

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Electromagnetic compatibility C.E.I.A Metal Detector is an apparatus which adapts well to the widest possible range of working conditions, and is especially immune to parasitic electromagnetic interference; however, to obtain best results, particularly at high sensitivity, a few precautions relating to the structure in which the detector is going to be placed should be taken.
  • Page 13 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Table II-A . Distances to be maintained between antennae and cabin structure 1: metal detector probe 2: external door 3: internal door 4: metal cabin structure Metal Detector inside an airlock- type cabin with...
  • Page 14 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Table II-B . Insulating a metal door 1) Fastening screw 2) Aluminium block 3) Fastening screws 4) Bakelite insulating plate thickness 3 mm. 5) Teflon-nylon insulating washer 6) Opening fastening screw 1 7) Aluminium upright...
  • Page 15: Electrical Interference

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Electrical interference Such interference is caused by the proximity to the antennae of power supply cables (electromagnetic field generated by alternating currents) or impulsive sources of electromagnetic interference (electric motors with a high ignition absorption and related power supply cables, fluorescent lights, emergency generators, air conditioning units, remote-control switches, etc.).
  • Page 16: Installation Of Coupled Metal Detectors - Synchronisation

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Installation of coupled metal detectors - synchronisation When two or more Metal Detectors are to operate near each other (generally within 10 metres), they must be synchronised by choosing an appropriate transmission channel for each one (CH function). Follow precisely the arrangement of the TX and RX antennas and the minimum distances indicated.
  • Page 17: Assembly

    Fig II-5fg column with bottom flange: Fig II-5e Example of conical insert, flange: anchoring via conical insert detail of holes for fixing screws fixed by expansion screw N.B.: The mechanical details shown in the figures (indicated by their grey colour) are not included by CEIA.
  • Page 18: Electrical Assembly

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Panels panel upper supporting structure fixing screws insert Anchoring via floor and ceiling screws use inserts of adequate thickness at the top Fig II-5h to avoid the panel being lifted up! Electrical assembly Connecting the electronics unit to the antennae.
  • Page 19: 02Pn8 Hi-Pe

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 02PN8 HI-PE 13 NC 12 NA 11 C 10 GND GND/-B ˜ +B/˜ 6 SER.GND 5 PP1 4 INIB 3 BUSY Fig. 33 Electronics unit with connectors in view (the connector cover is only on model 02PN8 2 SER OUT HI-PE) 1 SER IN...
  • Page 20: Iii - 02Pn7 Metal Detector - Instructions For Use

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 III - 02PN7 METAL DETECTOR – INSTRUCTIONS FOR USE Switching on the Metal Detector After turning ON the equipment, an audible signal will sound for a few seconds. During this period the output relay is activated. The Metal Detector will then be ready to operate. Any modification to the operating mode should be made by remote programming (See “Programming”...
  • Page 21: Free Access To Programming Phase (Without Password)

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Cable code Cable code C60300 SER GND C60169 INIB (COM1,COM2,...) C60300 BUSY SER OUT SER IN J1bis BUSY C60300 DB 9pin DB 9pin J1bis C60169 SER GND INIB Personal Metal BUSY Computer...
  • Page 22: Programming Of The 02Pn7 Metal Detector With Rcu

    Programming of the 02PN7 metal detector with RCU Connection The RCU module is a terminal which can be connected to the CEIA Metal Detectors by means of an RS-232 serial line. This device allows programming of all Metal Detector parameters from a remote position up to 100 metres from the detector.
  • Page 23: Free Access To Programming Phase (Without Password)

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Free access to programming phase (without password) • Position the switch of the RCU unit at the OFF position . Connect the unit to the metal detector. • Turn on the RCU unit using the built-in switch. •...
  • Page 24: Description Of The 02Pn7 Metal Detector Commands

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Description of the 02PN7 metal detector commands To see the standard values and the full list of the commands available at user level see the TEST CARD at the end of this booklet ( * : enabled command). Code of the function type : C= command R= status request...
  • Page 25: 02Pn7 Metal Detector Installation Checks

    ( command SE ) The sensitivity is pre-set in the factory according to the type of application. Generally, it is only necessary to check proper detection of a sample defined by security specifications or in some cases supplied by CEIA itself. Procedure •...
  • Page 26: 02Pn8 Hi-Pe Metal Detector - Instructions For Use

    FOR USE Switching on the Metal Detector After turning ON the equipment, an audible signal will sound (during this period the output relay is activated) and the electronics unit display will show the following information: CEIA MANUFACTURER 02PN8 MODEL ****...
  • Page 27: 02Pn8 Hi-Pe Metal Detector Stand-By

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Other messages For models fitted with it, emergency battery power supply is indicated by a flashing letter - - - - “B” on the right of the display. Self-diagnosis (example shows message indicating antenna damaged or disconnected GATE from the electronics unit) Implementation phase of operating parameter modification.
  • Page 28: Vi - 02Pn8 Hi-Pe Metal Detector - Programming

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 VI - 02PN8 HI-PE METAL DETECTOR - PROGRAMMING Local programming Use the keypad on the inside panel of the control unit. key is used to enter and exit the programming phase.
  • Page 29: Time Out

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 The remaining parameters can be both visualised and modified by the operator (the parameter can therefore function as a status request or as a command).The current value of the parameter is visualised on the display to the right of the function code.
  • Page 30: 02Pn8 Hi-Pe Metal Detector Transmission Parameters

    02PN8 HI-PE metal detector transmission parameters Code Meaning Possible Type Notes values Transmission To choose a different programme from the one pre-set in the factory, contact CEIA’s programme technical department. 0-99 Transmission 0 - 49 for 50Hz power supply channel...
  • Page 31: 02Pn8 Hi-Pe Metal Detector Management

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Possible Code Meaning Type Notes values Minimum alarm C/R/S 0 (disconnected alarm) volume 9 (maximum volume). This determines the minimum value of the AV parameter Alarm tone 5 different continuous tones ranging from 0 (deep sound) to 4 (high sound) 5 different pulsed tones ranging from 5 (deep sound) to 9 (high sound).
  • Page 32 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Code Meaning Possible Type Notes values Transmitter NO, YES It activates or deactivates the transmitter in case of inhibition of the metal detector. The inhibition behaviour of the metal detector in the two different situations is the following immediately operative when the inhibition signal is deactivated TI=NO the inhibition signal is deactivated.
  • Page 33: Analysis Programs Available With The Command "Is

    The command only relates to some parameters. This command requests confirmation. Output level This parameter is pre-set in the factory according to the actual Standards of the destination country. Please contact CEIA Sales Department for further information. Serial number of Metal Detector...
  • Page 34 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 The sensitivity is pre-set in the factory according to the type of application. Generally, it is only necessary to check proper detection of a sample defined by security specifications, or in some cases supplied by CEIA itself. Procedure •...
  • Page 35: Measurement Of The Quality Factor (02Pn8 Hi-Pe Metal Detector)

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 MEASUREMENT OF THE QUALITY FACTOR (02PN8 HI-PE metal detector) If the Metal Detector has to be installed inside a cabin, the system allows the FQ function to be accessed immediately: this allows measurement of the Quality Factor to be made easily, even by a person not skilled in programming the Metal Detector.
  • Page 36: Advanced Programming- Remote Programming

    Advanced programming- Remote programming Serial communication CEIA Metal Detectors can be programmed via the device’s keypad and/or from a remote PC station via a serial line connection to the RS 232 interface. The figure shows how to connect one or more Metal Detectors to a computer or modem.
  • Page 37: Communication System Configuration

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Communication system configuration 02PN8 HI-PE Metal Terminal or computer Detector Select the function mode on the computer: - type: ANSI/BBS, VT100 - baud rate Select the baud rate on - 8 data bits the Metal Detector - 1 stop bit...
  • Page 38: Advanced Programming: Use Of The Password

    At each programming level, only the password relating to that same level can be modified. The equipment is usually delivered from CEIA with a password already set for super-user level, while user . We recommend changing the passwords immediately after...
  • Page 39: Access To The Programming Phase Using The Password

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Access to the programming phase using the password Starting from normal operation, enter the password using the built-in keypad (local programming) or the terminal keyboard (remote programming). Local Programming Remote Programming The password is made up of 6 letters or numbers.
  • Page 40: Parameters Accessible From Remote Programming Only (02Pn8 Hi-Pe)

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Parameters accessible from remote programming only (02PN8 HI-PE) Function code : C= command R= status request S= the command can only be accessed from the super-user level Possible Code Meaning Type Notes...
  • Page 41: Technical Characteristics

    -35…+70°C (-31…158°F) • • A complete range of accessories for calibration and Relative humidity: 0 – 95%, without condensation. advanced management of CEIA Metal Detectors. Alarm modes Signalling Certifications and conformity • Detection of masses in transit (automatic or manual...
  • Page 42: 02Pn8 Hi-Pe

    • Autoset function to reset the default operating parameters Metal Detector Utilities • A complete range of accessories for calibration and PROGRAMMING advanced management of CEIA Metal Detectors. Presets Certifications and conformity 100 sensitivity levels Harmlessness G1/G2 100 attenuation levels •...
  • Page 43: Maintenance

    GATE disconnected and antennae • check that no nails or screws have been driven into the transducers without prior consultation with the technical department of CEIA. • replace the connecting cable damaged transducer • replace the transducer loading of data via the LD or IS commands •...
  • Page 44: Autotest Program

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Autotest program When the detector is switched on, a program may be run to test some of its components. Operations to carry out Display 02PN8 HI-PE Activating the Turn on the detector and keep the key of the 0 * 0 * 0 * 0 * central electronics unit pressed down until the signal...
  • Page 45: Troubleshooting

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Troubleshooting Before analysing possible faults, please check: • that the connectors are properly connected • that the operating parameters have the correct values (see the test check-sheet included at the end of the manual).
  • Page 46: Compatibility Aspects

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Compatibility aspects Problem Check and action The Metal Detector Check electrical interference using the EN function gives irregular • If EN>3: alarms with • eliminate the source of interference people objects •...
  • Page 47 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Problem Check and action • The variation slow follows door movement: in general: move the Metal detector further away from the door which causes the interference door made of metal sections: break the loop formed by the sections metal parts which pass close to the metal detector during movement of the door: replace with corresponding parts made of insulating material deformation of the supporting structure:...
  • Page 48: Column Antenna Orientation Procedure To Minimise Electrical Interference

    02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Column antenna orientation procedure to minimise electrical interference The procedure illustrated allows excellent results to be obtained only if there is a single clearly-defined source of interference of considerable strength in the cabin. If there are sources of noise present, either electrical or mechanical, it is important to take measures to reduce the interference as much as possible.
  • Page 49: Appendices

    DECLARATION OF CE CONFORMITY DECLARATION DE CONFORMITE CE KONFORMITÄTSERKLÄRUNG CE DECLARACION DE CONFORMIDAD CE DICHIARAZIONE DI CONFORMITÁ CE Manufacturer CEIA S.p.A. Fabricant / Herstellers / Fabricante / Costruttore: Strada Provinciale di Pescaiola 54/G 52040 Viciomaggio - Arezzo - ITALY Declares that the product déclare que ce produit / erklärt, daß...
  • Page 50: Spare Parts

    RX S046 panel; height: 2220mm 18248 TX S046 panel; height: 2220mm 32816 Photocell assembly 32716 Front cover with lock 19453 Keys (4) 29415 02PN8 HI-PE/CN-AS-140 Validity: revision 4 Description Quantity Code IP20 electronics unit 16208 Electronics unit connector assembly 22025 RX N000 column...
  • Page 51 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 Accessories Description HI-PE 02PN7 Quantity Code European power supply adapter (230V~) • • 37411 USA power supply adapter (115V~) • • 18348 RCU-2 • RCU-2 Extension-adapter C60181, for connecting the •...
  • Page 52 02PN8 HI-PE - 02PN7 --- Rev. FI 002 GB 60K10/16 v2_01 www.ceia.net...

This manual is also suitable for:

02pn8 hi-pe/cn-as-140l02pn8 hi-pe/pn-as-60002pn7

Table of Contents