SERVICING
Air conditioner/heat
pump may appear to be
operating nor mally.
Compressor protector
may be open (compressor
and outdoor f
Integrated control
module diagnostic/status
LED displ ay sho ws the
indicated code .
Air conditioner/heat
pump may appear to be
operating nor mally.
Integrated control
module diagnostic/status
LED displ ay sho ws the
indicated code .
.
Integrated control
module diagnostic/status
LED displ ay sho ws the
indicated code .
Air conditioner/heat
pump may appear to be
operating nor mally.
Compressor protector
may be open (compressor
and outdoor f
Integrated control
module diagnostic/status
LED displ ay sho ws the
indicated code .
Digit 2
Digit 1
Digit 3
H
8
High Line
Voltage
0
9
Low Pilot
Voltage
P
0
Comp
Protector
Open
0
8
08
High line
VO LT
voltage
LO W
09
Control detects
secondar y
VO LT
voltage less
than 18 VAC.
Tr ansf ormer
overloaded.
Low line voltage.
displayed
displayed
through run or
star t windings.
Compressor
run winding is
open.
Compressor not
properly wired to
control.
Faulty
compressor
wiring.
Failed
compressor r un
capacito r.
Faulty r un
capacitor wi ring.
08
VO LTAG E
PCBHR104
Correct high line
Tu rn power OFF pr ior
voltage condition;
to repai r.
contact local utility
Control detects line
if needed.
voltage greater than
Ve rify unit is
255 VAC.
connected to po wer
Fault will clear if line
voltage decreases
on rating plate .
below 255 VAC.
Chec k fuse .
Turn power OFF pr ior to
Correct lo w second -
repair.
ary voltage condition.
Fault will clear if
Chec k transf ormer;
secondar y voltage r ises
replace if needed.
above 21V AC.
Replace with correct
replacement par t(s).
Chec k compressor ;
Tu rn power OFF pr ior
repair/replace as
to repai r.
needed.
Fault will clear after 1
Chec k wiring; repair/
normal cycle .
replace as needed.
Fault ma y be cleared
Chec k r un ca -
by cycling 24V AC to
pacitor; replace as
control.
needed.
Replace with correct
replacement par t(s).
Chec k circuit
Tu rn power OFF pr ior
break er and fuses .
to repair.
Ve rify unit is con -
Control detects line
nected to po wer
voltage less than
185 VAC.
on rating plate .
Fault will clear if line
voltage increases
above 185 VAC.
65