108. Connect one end of the short length of red, heavy-wall, stranded hook-up wire to
E 1 (Solder). Pass other end of this wire through grommet F.
( i
/f
109. Leave a slight amount of slack in the four wires just installed. Then, secure wires
together with the small "U" shaped cable clamp by gently squeezing open ends of
clamp together with your pliers. Be very careful not to crush wires.
C
/),/110. Pull wires through grommet F from front of panel until clamp comes to rest
against grommet. Then, trim the red, green, and yellow wires to equal length,
using the shortest of the three as a guide. Do not trim the black lead.
( l,
r
111.
Solder the four small alligator clips to the ends of the four wires as shown in
"
Figure 13. Allow clips to cool, then slip an insulating sleeve over each clip.
/
( ,.f)"
112. Insert a 3/8" rubber grommet in hole at location P.
(r
J
113. Insert line cord from rear of chassis through grommet P. Tie an overhand knot
approximately 9" from end of cord inside chassis for strain relief. Separate cord
ends for a distance of 2-1/2".
(.}
114. Connect one lead of line cord to CA 2 (Solder).
Connect other lead to clip
0
(Solder).
( , )
115. Install the 1/2-amp fuse clips
0
and
N
on meter terminal board. Squeeze clips to ­
gether slightly for good contact grip.
Install the' silicon rectifier in clips K and L on meter terminal board so that positive
( +) end of rectifier is in clip K. Squeeze clips together slightly for good contact
grip.
(t,.. )/ 117. Install the small pOinter knob on "ADJUST LINE" control shaft. Rotate control
to
approximate center of its range.
Position white index mark on knob to "T" in
"ADJUST". Tighten knob set screw.
( t)
118.
Carefully inspect instrument construction. Be sure all wires and components have
been properly connected and soldered. Check positioning of wires and components
for possible short circuits. Turn the instrument over and shake out any loose
solder or wire cuttings.
PRELIMINARY TEST
Plug the T-65 line cord into a 117-volt, 60-cycle AC source. Set power switch to "ON".
Meter pointer should deflect to approximately mid-scale.
"ADJUST LINE" control should
move pointer to left and right. DepreSSing "READ METER" button should cause meter pointer
to fall back to "0" on scale.
H
the instrument fails to respond as indicated or if signs of trouble
such as smoke or overheating appear, disconnect the line cord from the power source and check
for wiring errors and short circuits. Further assistance in locating trouble may be found in the
section "COMPLETE CHECK-OUT PROCEDURE".
H
the instrument responds in the manner indicated, proceed to !1CALIBRA TION PRO ­
CEDURE."
CALIBRATION PROCEDURE
,/1.
, /
With power "OFFlt, zero adjust the meter in the position
it
will be used (usually horizontal).
)1: Use an accurate, high-impedance YOM, like PRECISION Model 120 or 110 or PACO Model
M-40. Set YOM to 6vAc or higher. Clip positive
(+)
YOM test prod tip to lug 6 (gray-yellow
lead) on "A" switch. Clip minus (-) YOM test prod tip to minus (-) end of the 100-mfd ca­
pacitor. Control and swit-ch settings do not matter.