ABB Cylon MATRIX-2 Series User Manual
Hide thumbs Also See for Cylon MATRIX-2 Series:

Advertisement

Quick Links

USER GUIDE
MAN0155 rev 4
Cylon® MATRIX-2 Series

Advertisement

Table of Contents
loading

Summary of Contents for ABB Cylon MATRIX-2 Series

  • Page 1 — USER GUIDE MAN0155 rev 4 Cylon® MATRIX-2 Series...
  • Page 2 Cylon PC Keyboard keys: Text representing an instruction to press a particular key on the keyboard is enclosed in square brackets and in bold font. For example: [Ctrl] ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 3: Table Of Contents

    LDAP Configuration ............................17 System Services ..............................17 System Status ..............................18 Process Status ..............................18 Project Performance ............................19 System Updates ..............................19 Backup/Restore ..............................20 Persistence Manager ............................21 ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 4 System Logs ......................25 ASPECT Control Engine Log ......................... 25 ASPECT Throttled Logs ..........................25 Diagnostic Buffer ............................. 26 Remote Logging ............................... 26 System Log .................................27 Update Log .................................27 ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 5: The Matrix-2 Series

    Receive alarms either from the integrated alarm console or through e-mail clients, or Twitter®. Schedule your building equipment through an integrated scheduler or by using common scheduling platforms such as Microsoft® Outlook®, Apple iCal, Google Calendar™. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 6: Installation

    RJ-45 pin connections 100-130 Ohms Characteristic impedance Less than 100 pF per meter (30 pF per foot) Distributed capacitance 328 ft. (100 m) maximum Maximum Cable length between IP devices ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 7: The Matrix-2 Integrated Ethernet Switch

    Max cable length TERMINATE THE MS/TP NETWORK If the MATRIX-2 is the first or last device on the network, then its MS/TP subnet terminator switch must be set to “ ” ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 8: Attach Rs-485 Communication Wires To The Ms/Tp Subnet Port

    Note: If the RS-485 network is wired to an eSC, then the shield will be grounded at the eSC. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 9: Matrix-2 Operation

    REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. Supply Requirements 24 V AC ±20 % 50/60 Hz Supply Rating 20 VA BACnet Loading ¼ unit load device ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 10: Terminals

    93, 94 24 V AC Power Important: The common power connection (terminal 93) must be connected to Earth. ABB Cylon recommend that this is done at the 24 V AC transformer. 95, 96 RS-485 Port 1 (BACnet® MS/TP) screw terminal MS/TP subnet terminator switch is located beside the port.
  • Page 11: Indicator Led Signals

    The Green indicator LED will stay off until reboot in complete. The Green indicator LED will begin to flash when reboot is done. • The Yellow indicator LED will be off unless there is a problem • ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 12: Software Configuration

    If your connection is successful, the main login page of ASPECT will be displayed: Enter the case-sensitive default username and password into the fields provided. Click the button. Log In ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 13: Control Panel

    SQLite Database Management Maintenance. SQLITE MAINTENANCE page provides users with the ability to manage the SQLite database. This page shows SQLite Maintenance the database files and sizes. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 14: Licensing

    MATRIX-2 Series device as well License as a method to upload/download license files. If a license file is uploaded, ABB Cylon recommends rebooting MATRIX-2 Series device to ensure the license file is successfully applied. ©ABB 2023 All Rights Reserved.
  • Page 15: Communication Setup

    Out Of Service Manager (OSS) out of service using the Manual OOS check boxes. BACNET SETTINGS area allows configuration of read/write retries, port configuration, and router BACnet Configuration settings for BACnet/IP. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 16: Bbmd Settings

    Modbus communications. Modbus Network Properties TIME SYNC SETTINGS area provides the ability to configure BACnet network time synchronizations. Time Sync Settings ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 17: System Administration

    Through this area, users can restart specific services of the MATRIX-2 Series device. Simply select an option from the drop-down and click . A message will indicate that the service has been Submit stopped/started/restarted successfully. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 18: System Status

    System Status utilization, disk space and all information pertaining to revision levels. PROCESS STATUS This shows the result of a command which produces an updating list of current processes running. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 19: Project Performance

    You may adjust this update timer by choosing Tab, and changing the Settings Global Settings Update time SYSTEM UPDATES area is used to perform firmware upgrades to the ASPECT device. System Updates ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 20: Backup/Restore

    BACKUP/RESTORE provides the means to backup an ASPECT target's device configuration (network addresses, Backup /Restore port and driver configuration, etc). To create a backup, simply click the button. Download ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 21: Persistence Manager

    Aspect project deployed to the Instance. When selecting this in the Control Panel, you will be prompted to re-enter your credentials in order to download a copy of the project. The required credentials will be the same as the ones used to originally deploy the project. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 22: Ethernet Settings

    To configure the device to use a static IP address, select the radio button, then Use the following IP Address enter your , and information into the boxes provided below. IP address Subnet Mask Gateway ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 23: Network Diagnostics

    Time Server Synchronization - Specifies an time server on the Internet with which to sync the system time to. Refer to pool.ntp.org for information relative to other available servers available. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 24: Web Server Configuration

    The Web Server Configuration area is used to set a label for the login screen and change port settings for the following: • - defaults to port 80 (HTTP) Aspect HTTP Port • - defaults to port 7226 Aspect Control Engine Port ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 25: System Logs

    ASPECT project. Up to 10 pages of ASPECT logs are contained and individual logs can be downloaded. ASPECT THROTTLED LOGS ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 26: Diagnostic Buffer

    All ASPECT targets Remote Logging support the ability to send their log information to a centralized ASPECT target or IT-supported syslog server. ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 27: System Log

    Information provided within this System Log log includes boot up details and lower level information regarding runtime of the system. UPDATE LOG shows all recent updates to the operating system. Update Log ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...
  • Page 28 Technology Park EXPORT, Clonshaugh PA 15632 Dublin 17 Ireland Tel.: +353 1 245 0500 Tel.: +1 724 733-2000 Fax: +353 1 245 0501 Fax: +1 724 327-6124 Email: info@cylon.com ©ABB 2023 All Rights Reserved. Subject to change without notice WWW.CYLON.COM...