Replacement; Engine Air Filter; Check And Clean - Mosa GE 3900 Use And Maintenance Manual

Hide thumbs Also See for GE 3900:
Table of Contents

Advertisement

7. Maintenance
8 - If the oil level is near or below the lower limit mark (Min.),
fill the oil to the upper limit mark (Max.) (lower edge of
the filler hole).
Oil: SAE SJ 10W-30 - API service SJ or higher
Tank capacity:
GE 3900 0.55 litres
GE 6900 1.1 litres

7.3.2 Replacement

1 - Place the generator on a level surface and start the en-
gine for a few minutes to heat the oil.
2 - Place a container under the cap (1) to collect the drained
oil.
3 - Unscrew the cap (1) and tilt the generator to let all the
engine oil flow out.
4 - Fill with new oil. For the details, see "7.3.1 Refuelling
and checks".
7.4

Engine air filter

WARNING
Clean the air filter more frequently if the generator set is used in dusty rooms.
Do not use petrol or flammable solvents to clean the filter.

7.4.1 Check and clean

1 - Unscrew the knob (2) to open the cover (1).
2 - Remove the air filter element (3).
3 - Wash the element with a solvent and dry it.
4 - Wet the element with oil and squeeze it out gently to
remove any excess oil.
Note
The element should be wet, but it shouldn't drip.
5 - Insert the element into the filter case ensuring that the
surface adheres to the case.
6 - Close the cover (1) and tighten the knob (2).
1
1
2
3
Max
Min.
D5261150
D5264280
D5264290
D5264300
31