Airxcel Coleman-Mach 48000 Series Installation, Operation And Maintenance Instructions

Airxcel Coleman-Mach 48000 Series Installation, Operation And Maintenance Instructions

Advertisement

Available languages

Available languages

INSTALLATION, OPERATION AND
MAINTENANCE INSTRUCTIONS FOR 48000

TABLE OF CONTENTS

I.
II.
III.
IV.
V.
VI.
VII.
VIII.
These instructions are a general guide for installing the 48000 Series Coleman-Mach roof top Heat Pumps.
For specific Heat Pump details, it will be necessary to refer to ALL printed documents supplied with this unit.
These instructions are for the use of qualified individuals specially trained and experienced in installation of this
type equipment and related system components.
Installation and service personnel are required by some states to be licensed. PERSONS NOT QUALIFIED
SHALL NOT INSTALL NOR SERVICE THIS EQUIPMENT.
NOTE:
The words "Shall" or "Must" indicate a requirement which is essential to satisfactory and safe product
performance. The words "Should" or "May" indicate a recommendation or advice which is not essential and not
required but which may be useful or helpful.
WARNING! - SHOCK HAZARD To prevent the possibility of severe personal injury or equipment damage due
to electrical shock, always be sure the electrical power source to the appliance is disconnected.
CAREFULLY FOLLOW ALL INSTRUCTIONS AND WARNINGS IN THIS BOOKLET TO AVOID DAMAGE TO
WARNING! Improper installation may damage equipment, can create a hazard and will void the warranty.
The use of components not tested in combination with these units will void the warranty, may make the equipment
in violation of state codes, may create a hazard, and may ruin the equipment.
P/N: 1980-023 Rev. 1
SERIES HEAT PUMPS
2
2
2
2
4
5
5
6
IMPORTANT NOTICE
THE EQUIPMENT, PERSONAL INJURY OR FIRE.
IX.
i.
ii.
iii.
iv.
v.
vi.
X.
XI.
1
8
8
9
9
9
11
11
23
24
08-24-2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Coleman-Mach 48000 Series and is the answer not in the manual?

Questions and answers

RUTH Mary ROTTON
April 24, 2025

Which Mach is my rv ac? Model #48254C969, Serial #140710032

1 comments:
Mr. Anderson
May 12, 2025

The model of the Airxcel Coleman-Mach 48000 Series RV AC with model #48254C969 is 48254C969.

This answer is automatically generated

Eric Jacobson
April 21, 2025

I need to power two of these 48000 units for my rv, but cannot find what BTU capacity they have. Can you tell me this and maybe recommend generator size I need?

1 comments:
Mr. Anderson
May 10, 2025

The BTU capacity of the Airxcel Coleman-Mach 48000 Series units is not provided in the given context. The recommended generator size to power two of them is also not stated.

This answer is automatically generated

Summary of Contents for Airxcel Coleman-Mach 48000 Series

  • Page 1: Table Of Contents

    INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR 48000 SERIES HEAT PUMPS Operation and Maintenance TABLE OF CONTENTS General Information General Information Heat Pump Sizing Control Panel Selecting an Installation Location Operation III. iii. Installing the Roof Top Unit Maintenance Wall Thermostat Identification Electrical Wiring Operation...
  • Page 2: General Information

    I. GENERAL INFORMATION III. SELECTING AN INSTALLATION LOCATION OEM – Please make sure all documentation Your Airxcel, Inc. Heat Pump has been designed for accompanies the Heat Pump. use primarily in recreational vehicles. INSTALLER AND/OR DEALER – Please make sure...
  • Page 3 Pull the electrical conduit down from the Airxcel’s 48000 series requires that the spacing from Heat Pump through the mounting opening and let the vehicle roof top to the interior ceiling be no less hang.
  • Page 4: Electrical Wiring

    Figure 4 V. ELECTRICAL WIRING DANGER! ROUTING 115 VAC WIRING WHEN USING NON-METALLIC SHEATH CABLES Following Airxcel’s high voltage wiring specifications (ROMEX, ETC.), STRIP SHEATH BACK and all local and national electrical codes, route the EXPOSE 4-6 INCHES OF THE SUPPLY LEADS.
  • Page 5: Installing Optional Heater Accessory

    VI. INSTALLING THE OPTIONAL HEATER ACCESSORY opening as shown in Figure 5. The heater bracket IMPORTANT NOTE must be installed over the metal basepan The optional Heater Accessory is intended to take extrusion and positioned between the basepan the chill out of the indoor air when the air is a few and the plastic drain pan (See Figure 6).
  • Page 6: System Checkout

    Figure 9 VIII. SYSTEM CHECKOUT Airxcel manufactures a wide range of rooftop Heat Pumps which incorporate different product operation features. To properly evaluate the performance of a newly installed Heat Pump, it is necessary to review the specific unit operation characteristics (features) described in the product OPERATION AND MAINTENANCE INSTRUCTIONS...
  • Page 7 Apply today by filling out the application located on the back cover of this Installation and Operation Manual and mailing it in along with your check or money order to Airxcel, Inc., P.O. Box 4020, Wichita, KS 67204. A contract will be sent to you within a few weeks. You should retain with your paperwork for proof of purchase.
  • Page 8: Operation And Maintenance

    IX. OPERATION AND MAINTENANCE INSTRUCTIONS FOR 48000 SERIES ROOF TOP HEAT PUMPS AND CEILING PLENUMS i. GENERAL INFORMATION As long as this temperature difference is being maintained between the return air and discharge air, NOTE: An optional auxiliary electric resistance the heat pump is operating at its capacity.
  • Page 9: Control Panel

    ii. CONTROL PANEL important to leave it off for two to three minutes before restarting. If your RV Heat Pump is operated from the control Short cycling the compressor (or starting it before panel located in the ceiling assembly, then there are pressures have equalized), will in some instances, three controls on the ceiling assembly that help you kick the circuit breaker or overload.
  • Page 10 IMPORTANT compressor on the Heat Pump fails to start, check with your Airxcel, Inc. Service Center to determine Do not operate your Heat Pump for extended that the proper wire size is connected to the unit, periods of time without the filter installed.
  • Page 11: Wall Thermostat Identification And Operation

    Applications must be made within ninety (90) days Airxcel, Inc. support help may be accessed by e-mail of the original purchase. RVPSupport@Airxcel.com. written 3. Inquiries about your Coleman-Mach Heat Pump...
  • Page 12 INSTALLATION, D’UTILISATION ET D’ENTRETIEN POUR 48000 POMPES SÉRIE DE CHALEUR Opération et maintenance TABLE DES MATIERES Informations générales Informations générales Panneau de Controle Sélection d’une pompe à chaleur appropriée iii. Functionnement Sélection de l’emplacement Entretien III. d’installation Identification et functionnement du Installation de l’unité...
  • Page 13: Informations Générales

    Une pompe à chaleur ne devrait pas être prise en www.Airxcel. com. Utilisez l’applicaiton sur le dos de considération pour le remplacement intégral d’une fonctionnement et d’entretien instructions pour fournaise. La pompe à chaleur ne fonctionnera pas à...
  • Page 14 La série 48000 d’Airxcel exige un écart minimum de ensemble de ressorts tampons, pièce n° 8333-3871, 2,54 cm (1 po) entre le toit du véhicule et son plafond afin de maintenir la tension sur les boulons et retarder (intérieur).
  • Page 15 Figure 2 Figure 1 Figure 3 Figure 4...
  • Page 16: Câblage Électrique

    V. CÂBLAGE ÉLECTRIQUE DANGER! ACHEMINEMENT DU CÂBLAGE 115 V CC LORSQUE OUS EMPLOYEZ DES CÂBLES À En respectant les spécifications d’Airxcel, Inc. pour le GAINE NON MÉTALLIQUE (ROMEX, ETC.), câblage haute tension et l’ensemble des codes de D’ALIMENTATION DÉNUDEZ LES CÂBLES l’électricité...
  • Page 17: Installation De L'accessoire De Chauffage Facultatif

    VI. INSTALLATION DE L’ACCESSOIRE DE VII. INSTALLATION DE L’ENSEMBLE DE CHAUFFAGE FACULTATIF PLAFOND (SÉRIE 9600) Confirmez que vous avez correctement apparié la IMPORTANT REMARQUE : pompe à chaleur de toit et l’ensemble de plafond. L’accessoire de chauffage facultatif sert à éliminer Vous devez exécuter les instructions pas à...
  • Page 18: Vérification Fonctionnelle Du Système

    Figure 7 Figure 8 Figure 9 VIII. VÉRIFICATION FONCTIONNELLE DU SYSTÈME Airxcel, Inc. fabrique gamme étendue de pompe à chaleurs de toit qui incorporent différentes caractéristiques de fonctionnement de produit. Afin de correctement évaluer la performance d’une pompe à chaleur nouvellement installée, vous devez examiner les caractéristiques de fonctionnement propres à l’unité...
  • Page 19 GARANTIE dans la barre de recherche. AIRXCEL, INC. - RV Products Division • 3050 N. St. Francis St. • Wichita, KS 67219 316.832.3400 • www.AIRXCEL.com Coleman est une marque déposée de The Coleman Company, Inc., utilisée sous licence. Mach est une marque déposée.
  • Page 20: Opération Et Maintenance

    IX. MODE D’EMPLOI ET UTILISATION SÉRIES 48000 DES POMPE À CHALEURS DE TOIT DES PLÉNUM DE PLAFOND 80 degrés F., l’air sortant des grilles d’évacuation de i. RENSEIGNEMENTS GÉNÉRAUX la pompe à chaleur sera de 60 à 65 degrés F. NOTE: Un auxiliaire en option résistance électrique Tant que cette différence de température est chauffage peut être installé...
  • Page 21: Panneau De Controle

    ii. PANNEAU DE CONTRÔLE maximum, le serpentin du refroidisseur ne devrait pas Si votre pompe à chaleur de VR fonctionne à partir avoir de glace. d’un panneau de contrôle au plafond, il y a alors trois III. Fonctionnement en courts cycles commandes au plafond pour aider à...
  • Page 22: Entretien

    électriques ne doivent être effectués que par un personnel d’entretien qualifié. Contactez votre iv. ENTRETIEN centre d’entretien Airxcel, Inc. s’il y a des I. Propriétaire problèmes. Un des plus grands avantages de votre nouveau B. Points de contrôle – Les pompe à chaleurs ont pompe à...
  • Page 23: Serial Number Nomenclature

    Pour ce faire, remplissez la carte de demande également visiter notre site Web á l’adresse agrafée à l’avant de cette enveloppe. Veuillez www.Airxcel.com pour consulter les réponses aux envoyer la carte et un chèque ou un mandat à questions les plus fréquemment posées ainsi que les l’adresse mentionnée ci-dessus.
  • Page 24: Optional Extended Warranty

    Apply today by filling out the application below and mailing it with your check or money order for $89.95 to Airxcel, Inc., P.O. Box 4020, Wichita, KS 67204. A contract will be sent to you within a few weeks. You should retain with your paperwork for proof of purchase.

Table of Contents