Summary of Contents for GLAZING VISION GV Standard Pyramid
Page 1
GV Standard Pyramid Installation Instruction Manual “Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.”...
Page 2
1. The Pyramid should arrive on site in undamaged packaging, which includes sterling board side protection, polyfoam glass protection and low-tack tape base protection. Please inspect for damage to packaging and/or rooflight and advise Glazing Vision upon receipt. 2. Enclosed within the box containing this manual is a roll of butyl tape, the required number of fixing woodscrews and a number of horseshoe packers.
Page 3
The construction of the kerb is detailed more specifically on standard drawing 404- ASS-402. 7. Before starting installation, Glazing Vision advises that the physical kerb dimensions are cross-checked with those given for the order, to ensure the rooflight will fit (refer to drawings S0009/10).
Page 4
Page 4 of 8 Installation Procedure: Fixed 1. Place two runs of butyl tape around the base of the Pyramid as shown in Figure 1 and place the Pyramid onto your kerb ensuring that it is centred, i.e. drip flashing overhanging equally round all sides.
Page 5
Care should be taken when tightening the fixings to ensure the frame does not distort. Figure 3 – Packing and fixing 3. After applying all fixings clip on the covers around the base perimeter. 4. For connecting the Pyramid downlighter, please refer to Glazing Vision’s standard drawing 404-ASS-426.
Page 6
Page 6 of 8 Installation Procedure: Opening 1. Before removing the packaging if possible turn the vent on to its side and apply 2 Figure 4 continuous beads of butyl tape to the base of the Pyramid as shown in .
Page 7
Kerb structure with cable entry hole refer to drawing 404-ASS-414 for dimensioning details. Kerb not supplied by Glazing Vision Figure 6- Position of power and control cables in motor housing 3. Carefully lower the rooflight onto the kerb top ensuring that cables are not trapped i.e.
Page 8
When you are ready to run the Pyramid press and hold the operating switch in the open direction. If the mechanisms do not function as expected within a few seconds release the switch and contact Glazing Vision for assistance.