Autonics KRN100 Series Manual
Hide thumbs Also See for KRN100 Series:

Advertisement

Quick Links

KRN100
Features
Combined•functions•of•paper•recorder•and•paperless•
• •
recorder
• E nables•to•print•the•saved•data•of•inner•memory•
• •
when•running•out•of•recording•paper•
(data•logger•function)•
Enables•to•set•parameters•with•USB,•RS485,•Ethernet•
• •
communication
• H igh•legibility•and•setting•convenient•by•graph•LCD•
• •
• H igh•speed•sampling•of•25ms,•high•speed•record•of•
• •
240mm/H•functions•
• 1 00mm•paper•record•(selectable•6•kinds•of•record•
• •
color)•
Supports•inner•memory•and•USB•memory•data•
• •
backup•(storage)
Supports•several•input•up•to•12•channels•with•slot•
• •
type•input•cards
Enables•to•select•several•option•cards•with•slot•type•
• •
output•cards
• S pace•saving•for•installation•with•compact•design•
• •
(rear•length:•168mm)
• S upports•total•27•kinds•of•input•types
• •
Enables•to•order•several•type•input•cards•(weight,•
• •
voltage,•current,•frequency,•potential•meter,•etc)•
Manual
• • For•more•information•and•instructions,•refer•to•the•user•manual•and•the•user•manual•for•communication.•
Visit•our•web•site•(www.autonics.com)•to•download•the•manuals.
• • The•user•manual•includes•product•specifications,•functions,•and•operations.
• • The•user•manual•for•communication•includes•information•about•Modbus•RTU•protocol,•Modbus•TCP•protocol,•and•Modbus•
mapping•table.•
Integrated device management program(DAQMaster)
• • DAQMaster•is•the•integrated•device•management•program•to•set•parameters•and•manage•monitoring•data.
• • Visit•our•website•(www.autonics.com)•to•download•user•manual•and•integrated•device•management•program.
<•Computer•specification•for•using•software•>
Item
System
Operating•system Microsoft•Windows•98/NT/XP/Vista/7
Memory
Hard•disk
VGA
Others
A-2
Series
Minimum•requirements
IBM•PC•compatible•computer•with•Intel•Pentium•
Ⅲ•or•above
256MB•or•more
More•than•1GB•of•free•hard•disk•space
1024×768•or•higher•resolution•display
RS-232•serial•port(9-pin),•USB•port
Please read "Caution for your safety" in operation manual
before using this unit.
<•DAQMaster•screen•>

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KRN100 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autonics KRN100 Series

  • Page 1 • • Enables•to•order•several•type•input•cards•(weight,• • • voltage,•current,•frequency,•potential•meter,•etc)• Manual • • For•more•information•and•instructions,•refer•to•the•user•manual•and•the•user•manual•for•communication.• Visit•our•web•site•(www.autonics.com)•to•download•the•manuals. • • The•user•manual•includes•product•specifications,•functions,•and•operations. • • The•user•manual•for•communication•includes•information•about•Modbus•RTU•protocol,•Modbus•TCP•protocol,•and•Modbus• mapping•table.• Integrated device management program(DAQMaster) • • DAQMaster•is•the•integrated•device•management•program•to•set•parameters•and•manage•monitoring•data. • • Visit•our•website•(www.autonics.com)•to•download•user•manual•and•integrated•device•management•program. <•Computer•specification•for•using•software•> <•DAQMaster•screen•> Item Minimum•requirements IBM•PC•compatible•computer•with•Intel•Pentium• System Ⅲ•or•above Operating•system Microsoft•Windows•98/NT/XP/Vista/7 Memory 256MB•or•more Hard•disk More•than•1GB•of•free•hard•disk•space...
  • Page 2: Ordering Information

    100mm Hybrid Recorder Ordering information A. Recorder Ordering information for recorder model B.•Indicator KRN100 C.•Converter ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ D.•Controller Item Description ①•Item KRN100 New•100mm•Paper•Type•Recorder E.•Thyristor• •••••unit 2-channel(KRN-UI2×1EA) 4-channel(KRN-UI2×2EA) F.•Pressure• ••••transmitter 6-channel(KRN-UI2×3EA) ②•Input•channel 8-channel(KRN-UI2×4EA) G.•Temp.• •••••transmitter 10-channel(KRN-UI2×5EA) 12-channel(KRN-UI2×6EA)
  • Page 3 KRN100 Series Connections Rear side of KRN100 standard model This•figure•is•the•rear•side•of•KRN100-04000-00-0S. SOURCE 100-240VAC 50/60Hz,•55VA Slot Description 1•to•6 Connects•universal•input•card(KRN-UI2).• Connects•digital•input•card(KRN-DI6),•alarm•output•card(KRN- 7•to•10 AR4,•KRN-AT6),•transmitter•power•output•card(KRN-24V3).• Connects•communication•output•card(KRN-COM). I/O card Universal input card [KRN-UI2] Digital input card [KRN-DI6] ※ Each•channel•is•isolated•and•dielectric•strength•is•500V. Alarm output card [KRN-AR4(relay output)] Alarm output card [KRN-AT6(transistor output)] Inner Inner 250VAC•3A•1a...
  • Page 4: Specifications

    100mm Hybrid Recorder Specifications A. Recorder Series KRN100 B.•Indicator Power•voltage 100-240VAC•50/60Hz Allowable•voltage•range 85•to•110%•of•rated•voltage C.•Converter Power•consumption Max.•55VA LCD•type STN•Graphic•LCD D.•Controller Resolution 320×120Pixel Screen Adjusting•brightness 4-level(OFF/Min/Standard/Max) E.•Thyristor• Backlight White•LED,•2-level(Temp/Always) •••••unit Input•channels 2•/•4•/•6•/•8•/•10•/•12-channel(2-channel/card)-Expandable F.•Pressure• Universal•input Temperature•sensor(RTD,•thermocouple),•analog ••••transmitter ※1 1•to•4-channel•:•25ms/125ms/250ms,•5•to•12-channel•:•125ms/250ms G.•Temp.• Sampling•cycle (inner•sampling•cycle•is•operation•unit•time•for•average•movement•filter•and•alarm•output•function.) •••••transmitter ※Max.•sampling•cycle•for•TC-R,•U,•S,•T•sensor•is•50ms.
  • Page 5 KRN100 Series I/O card Type Model I/O•specifications Descriptions JPt100Ω,•DPt100Ω,•DPt50Ω,•Cu100Ω,Cu50Ω(supply•current••420㎂) Thermocouple B,•C(W5),•E,•G,•J,•K,•L,•L(Russia),•N,•P,•R,•S,•T,•U Input•type ※ 1 Voltage:•±60mV•±200mV•±2V,•1-5V,•±5V,•-1V-10V Analog Current:•0.00-20.00mA,•4.00-20.00mA Voltage(V):•Min.•150kΩ Input•impedance RTD,•Thermocouple,•Voltage(mV):•Min.•2MΩ Universal•input• KRN-UI2 Current:•51Ω card Warm-up•time:•Min.•30•min. Room•temperature•(25℃±5℃):•±0.1%F.S•±1digit Display• Thermocouple Out•of•room•temperature•range:•±0.2%F.S•±1digit accuracy ※ 2 For•RTD,•500•to•800℃•is•±0.5%±1digit•of•PV•value,• Analog For•Thermocouple,•below•-100℃•is•±0.3%F.S.±1digit. Resolution 16Bit Non-contact•input ON:•Max.•1V•of•residual•voltage,•OFF:•Max.•0.1mA•of•leakage•current Digital•input•card• KRN-DI6•...
  • Page 6: Input Type And Range

    100mm Hybrid Recorder Input type and range A. Recorder Input•range B.•Indicator Input•type Display ℃ ℉ K(CA) TC-K -200.0 to• 1350.0 -328.0 to•2462.0 73.2 to•1623.2 C.•Converter J(IC) TC-J -200.0 to• 800.0 -328.0 to•1472.0 73.2 to•1073.2 E(CR) TC-E -200.0 to• 800.0 -328.0 to•1472.0 73.2 to•1073.2 D.•Controller T(CC)
  • Page 7: Part Descriptions

    KRN100 Series Part descriptions Front and side part ⑤ ① ④ ② ③ ①•Display•part:•Displays•measurement•values•as•trend•graph,•bar•graph,•or•digital•number•(1/8/12•channel).• •••••Please•refer•to「Screen•display」of•the•A-13p. ②•Recording•print•part:•Records•measuring•value•of•data•by•each•channel•with•designated•color. ③•Channel•information•part:•Write•the•information•by•each•channel.• ④•Control•key/Function•key:•Executes•parameter•setting•and•recording,•and•special•function.• Function Used•for•starting/stopping•recording,•changing•input•characters•on•virtual•keyboard•status,•and•displaying•Function• key.•Press•this•key•for•3•sec.•in•stop•state,•the•ink•cartridge•moves•to•the•center. •(Use•this•key•to•replace•the•ink•cartridge.) Used•for•going•out•from•parameter•setting•group•or•setting•manual•channel•switch•mode. It•also•executes•to•release•auto•channel•switch•mode•and•printer•list•output•(3•sec.)•function.• Used•for•moving•parameter•in•setting•mode,•setting•manual•channel•switch•mode•and•forced•alarm•reset•(3•sec.). Used•for•moving•parameter•in•setting•mode,•increasing•digit•value,•setting•auto•channel•switch•mode,•and•manual• feed•function•(by•pressing•over•3•sec.)•in•stop•state. Used•for•moving•parameter•in•setting•mode,•decreasing•digit•value,•changing•display•mode•and•executing•manual• digital•memo•(3•sec.)•in•recording•state. Used•for•entering•setting•mode•(3•sec.)•and•set•value•change•mode. ⑤•USB•port•:Connects•an•USB•memory.•It•recognizes•max.•32Gbyte•and•if•using•cable,•it•is•available•up•to•1.5m. ※ • F unction•key:• • Use•this•key•to•enter•virtual•keyboard•in•parameter•setting. • Press•the• •key•and•Function•key•appears•on•lower•screen•as•below• figure.•Press•the•...
  • Page 8: Paper Cassette

    100mm Hybrid Recorder Inside A. Recorder ① ①•Ink•cartridge(model:•D33006B-66X-01) ②•Recording•paper•cassette B.•Indicator Cassette•saves•the•recording•paper. ② ③•Recording•paper•cassette•lever C.•Converter Press•the•lever•down•and•this•recording•paper•cassette•is• removed•from•KRN100. ※ • R emove•the•recording•paper•cassette•for•recording•paper• D.•Controller replacement,•ink•cartridge•replacement. E.•Thyristor• •••••unit F.•Pressure• ③ ••••transmitter Paper cassette ①•Recording•paper•holder G.•Temp.• ① ⑤ Movement•holder•of•recording•paper•when•recording •••••transmitter ② Recording•paper•storage•part ④ Storage•part•for•recorded•recording•paper H.•Accessories ③•Front•cover•of•recording•paper•storage Open•recording•paper•guide•for•recording•paper•replacement•...
  • Page 9: Memory•Setup

    KRN100 Series Standard record period [ Standard Period ] ٧ Two Unit For•compound•pressure,•if•input•pressure•is•lower•than• Set•record•period•to•record•current•time,•display•value•by• atmospheric•pressure(0),•it•displays•the•degree•of•a• channel•as•digital•number•on•recording•paper. vacuum•with•mmHg•unit.•If•input•pressure•is•higher• It•is•activated•when•Record•Mode(Record•mode)•is•Digital. than•or•same•as•atmospheric•pressure(0),•it•displays• • • • S et•range:•00m•01s•to•99m•59s positive•pressure•with••kg/cm •unit. • Depending•on•the•number•of•recording•channels,•min.• When•using•Two•Unit•function,•lower•limit•value•is•fixed• set•range•is•limited•as•below. as•-760mmHg•and•kg/cm 2• value•is•able•to•set•within•set• range•1•to•35. Record•channel Set•range Two•Unit•limits•scale•point•as••0•↔•0.0•↔•0.00•.•When• 1•to•2 01m•00s•to•99m•59s using•Two•Unit,•display•unit•is•automatically•changed• 3•to•4 02m•00s•to•99m•59s as•mmHg•or•kg/cm...
  • Page 10: Firmware Upgrade

    100mm Hybrid Recorder ※ • B e•sure•that•if•selecting•‘Default.pms’•file,•every• Firmware upgrade set•value•is•initialized•as•factory•default.•Save•the• A. Recorder Upgrades•KRN100•firmware. current•set•parameter•as•Save•Set•File•(parameter• setting•file•storage)•at•first•and•initialize•it•for•the• When•upgrading•firmware,•parameters’•set•values•are• B.•Indicator initialized. provision. ※ One file from•User1.pms•to•User5.pms,•User1.pms• • • • S et•range:•- • • • F actory•default:•Auto•set• (USB)•to•User5.pms(USB)•is•selected,•all•parameter• C.•Converter setting•information•of•KRN100•is•changed•as•the•set• ※ • D uring•firmware•upgrade,•alarm•output,•digital•input•and• value•of•the•selected•parameter•save•file.•...
  • Page 11 KRN100 Series Communication setting [COMMUNICATION SETUP ] Set•the•related•parameters•with•communication•output• Visit•our•homepage•(www.autonics.com)•to•download• card(KRN-COM). DAQMaster•program,•and•user•manual•for•communication.• You•can•only•check•the•item•of•COMMUNICATION•SETUP• Move•to•COMMUNICATION•SETUP•with•the• ,• • by•communication•but•cannot•change•the•set.• keys,•press•the• •key•to•enter•COMMUNICATION• This•parameter•is•for•setting•and•monitoring•parameters• SETUP. from•external•upper•system•(PC•and•graph•panel,•etc)• KRN100•does•not•supports•RS485•port,•Ethernet• or•transmitting•the•data•to•external•devices•by•RS485,• port•at•the•same•time•for•preventing•system•overload.• Ethernet,•or•USB•Device•communication. If•you•change•one•as「Enable」,•the•other•is• It•is•recommended•to•use•our•dedicated•software•program• changed「Disable」automatically.•• DAQMaster•for•monitoring.•If•you•want•to•develop• In•case•USB•Device,•it•is•able•to•set• monitoring•program•not•using•our•DAQMaster•program•or• 「Enable」,「Disable」regardless•of•RS485•or•Ethernet• to•use•the•related•Modbus•program,•please•refer•to•user• setting. manual•for•communication.• ٧ Interface Item RS485 Ethernet Application•standard...
  • Page 12 100mm Hybrid Recorder Adjustment A. Recorder Screen display change B.•Indicator Trend•graph Bar•graph C.•Converter D.•Controller Digital•number E.•Thyristor• •••••unit Special functions for record F.•Pressure• Parameter ••••transmitter Start/Stop•recording 3•sec. setting mode group G.•Temp.• Parameter•setting•information•print •••••transmitter 3•sec. H.•Accessories Manual•feed•(when•recording•stops) 3•sec. Digital•memo 3•sec. Parameter setting Function•key KRN100 KRN50...
  • Page 13: Run Mode

    KRN100 Series Parameters RUN mode ※ •Dot•parameters•may•or•may•not•appear,•depending•on•the•other•parameter•setting. 3 sec. DIGITAL INPUT COMMUNICATION INPUT SETUP ALARM SETUP SETUP SETUP (input setting) (alarm setting) (digital input setting) (com. setting) Select UI Card Select UI Channel Select DI Card Modbus Address (universal input card (universal input (digital input card (com.
  • Page 14: Record Setup

    100mm Hybrid Recorder A. Recorder B.•Indicator C.•Converter FILE/MEMORY USER/INFORMATION RECORD BACKUP RECORD SETUP SYSTEM SETUP SETUP SETUP DATA D.•Controller (record setting) (system setting) (file/memory setting) (user/info. setting (backup data record setting) E.•Thyristor• •••••unit Load Set File Record Mode Device Name Password Record Backup F.•Pressure•...
  • Page 15: Factory Default

    KRN100 Series Factory default Input setting group [ INPUT SETUP ] Parameter Default Parameter Default Parameter Default Parameter Default Select•UI•Card Auto•set Input•Type TC-K Low•Scale/High•Scale Record•Method Instant Input•Set•Copy CH•Select Range/Scale•Point Special•Function None Filter•Type None TC,•RTD ℃ LCD/Paper•Record Two•Unit Filter•Counter Display/Temp•• Unit• Pen•Color Auto•set Analog...
  • Page 16 100mm Hybrid Recorder A. Recorder User/Information setting group [ USER INFORMATION SETUP ] B.•Indicator Parameter Default Parameter Default Parameter Default C.•Converter Password Disable Change•Admin•Password - Information Display... Login•Admin User•Lock Firmware•Upgrade Auto•set D.•Controller E.•Thyristor• Backup data record setting group [ RECORD BACKUP_ SETUP ] •••••unit Parameter Default...

Table of Contents