Autonics krn100 series User Manual
Autonics krn100 series User Manual

Autonics krn100 series User Manual

100mm hybrid recorder
Hide thumbs Also See for krn100 series:

Advertisement

Preface

USER MANUAL

For COMMUNICATION
© Copyright Reserved Autonics Co., Ltd.
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the krn100 series and is the answer not in the manual?

Questions and answers

Summary of Contents for Autonics krn100 series

  • Page 1: User Manual

    Preface USER MANUAL For COMMUNICATION © Copyright Reserved Autonics Co., Ltd.
  • Page 2 © Copyright Reserved Autonics Co., Ltd.
  • Page 3: Preface

    Preface Preface Thank you for choosing our Autonics products. Please familiarize yourself with the information contained in the Safety Considerations section before using this product. This user manual for communication contains information about the product and its proper use, and should be kept in a place where it will be easy to access.
  • Page 4: User Manual Guide

    The manual's content may vary depending on changes to the product's software and other  unforeseen developments within Autonics, and is subject to change without prior notice. We contrived to describe this manual more easily and correctly. However, if there are any ...
  • Page 5: User Manual For Communication Symbols

    Failure to follow instructions can result in serious injury or death. Failure to follow instructions can lead to a minor injury or product damage. An example of the concerned feature's use. Annotation mark. ※1 © Copyright Reserved Autonics Co., Ltd.
  • Page 6: Safety Considerations

    Failure to follow this instruction may result in electric shock or shortening the life cycle of the unit. When connecting the power input or measuring input, power cable should be over AWG  20(0.50mm ). Make sure to tighten the terminal screw bolt above 0.74 N•m to 0.90 N•m. © Copyright Reserved Autonics Co., Ltd.
  • Page 7 Alarm output, contact input, data measurement do not operate normally. After completing firmware upgrade, check the complete message and turn OFF to ON the  power. Failure to follow this instruction may result in malfunction. © Copyright Reserved Autonics Co., Ltd.
  • Page 8 Use voltage output of transmitter power output card only for transmitter power.  Failure to follow this instruction may result in output module damage. The specifications and dimensions of this manual are subject to change without notice. viii © Copyright Reserved Autonics Co., Ltd.
  • Page 9: Table Of Contents

    DIGITAL INPUT SETUP(Digital input setting) ..........73 3.4.4 COMMUNICATION SETUP(Communication setting) ........ 77 3.4.5 RECORD SETUP(Record setting .............. 78 3.4.6 SYSTEM SETUP(System setting) ............. 80 3.4.7 FILE/MEMORY SETUP(File/Memory setting) ..........81 3.4.8 USER INFORMATION SETUP(User information setting) ......81 © Copyright Reserved Autonics Co., Ltd.
  • Page 10: Table Of Contents

    Table of Contents © Copyright Reserved Autonics Co., Ltd.
  • Page 11: Modbus Rtu Protocol

    Byte Count Error Check(CRC16) Function Data Data Slave Address (Number of (Command) High (00008 to 00001) (00010 to 00009) data byte) 11 H 01 H 02 H CD H 01 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 12: Read Input Status(Func02-02H)

    Byte Count Error Check(CRC16) Function Data Data Slave Address (Number of (Command) High (00008 to 00001) (00010 to 00009) data byte) 11 H 02 H 02 H CD H 01 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 13: Read Holding Registers(Func03-03H)

    Byte Count Data Data Error Check(CRC16) Function Slave Address (Number of (Command) High High High data byte) 11 H 03 H 04 H 02 H 2B H 00 H 64 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 14: Read Input Registers(Func04-04H)

    Byte Count Data Data Error Check(CRC16) Function Slave Address (Number of (Command) High High High data byte) 11 H 04 H 04 H 00 H 0A H 00 H 14 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 15: Preset Single Registers(Func06-06H)

    ## H ## H Response(Slave)  Function Starting Address Preset Data(Data) Error Check(CRC16) Slave Address (Command) High High High 11 H 06 H 00 H 00 H 00 H 0A H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 16: Preset Multiple Registers(Func16-10H)

    PC loader program, it is recommended to use signle register write (Single Register Write) than multi register write (Multi Regiter Write) to connect external device such as PLC, graphic panel, etc. © Copyright Reserved Autonics Co., Ltd.
  • Page 17: Exception Process (Exception Response-Error Code)

    E8 H 00 H 01 H ## H ## H Response (Slave)  Function Error Check(CRC16) Slave Address (Command) Exception Code High +80 H 11 H 81 H 02 H ## H ## H © Copyright Reserved Autonics Co., Ltd.
  • Page 18 1 Modbus RTU protocol © Copyright Reserved Autonics Co., Ltd.
  • Page 19: Modbus Tcp Protocol

    (Unit: Byte) (Unit: Byte) Copies and transfers Unit Identifier 1 Byte Identifier Allots from Client the received value from the Master TCP/IP communication port uses "502". For more information about MODBUS TCP, refer http://modbus.org/docs/Modbus_Application_Protocol_V1_1b.pdf file. © Copyright Reserved Autonics Co., Ltd.
  • Page 20: Read Coil Status(Func01-01H)

     Function Byte Count Data Data MBAP Header (Command) (Number of data byte) (000008 to 000001) (000010 to 000009) 00 0a 00 00 00 05 01H 01 H 02 H CD H 01 H © Copyright Reserved Autonics Co., Ltd.
  • Page 21: Read Input Status(Func02-02H)

     Byte Count Function Data Data MBAP Header (Number of data (Command) (000008 to 000001) (000010 to 000009) byte) 00 07 00 00 00 05 01H 02 H 02 H CD H 01 H © Copyright Reserved Autonics Co., Ltd.
  • Page 22: Read Holding Registers(Func03-03H)

     Byte Count Data Data Function MBAP Header (Number of data (Command) High High byte) 00 0a 00 00 00 07 01H 03 H 04 H 02 H 2B H 00 H 64 H © Copyright Reserved Autonics Co., Ltd.
  • Page 23: Read Input Registers(Func04-04H)

     Byte Count Data Data Function MBAP Header (Number of data (Command) High High byte) 00 0b 00 00 00 07 01H 04 H 04 H 00 H 0A H 00 H 14 H © Copyright Reserved Autonics Co., Ltd.
  • Page 24: Preset Single Registers(Func06-06H)

    00 H 00 H 0A H Response(Slave)  Function Starting Address Preset Data(Data) MBAP Header (Command) High High 00 0c 00 00 00 07 01H 06 H 00 H 00 H 00 H 0A H © Copyright Reserved Autonics Co., Ltd.
  • Page 25: Preset Multiple Registers(Func16-10H)

    PC loader program, it is recommended to use signle register write (Single Register Write) than multi register write (Multi Regiter Write) to connect external device such as PLC, graphic panel, etc. © Copyright Reserved Autonics Co., Ltd.
  • Page 26: Exception Process (Exception Response-Error Code)

    00 0d 00 00 00 06 01H 01 H 03 H E8 H 00 H 01 H Response (Slave)  Function (Command) MBAP Header Exception Code +80 H 00 0d 00 00 00 03 01H 81 H 02 H © Copyright Reserved Autonics Co., Ltd.
  • Page 27: Modbus Mapping Table

    01/05 R/W Digital Memo Digital memo output 0:OFF, 1:Digital Memo - Pulse form. 000005 to 01/05 R/W Reserved 000050 In case of Feed, List Out, Digital Memo, whenever "1" is input, it operates once. © Copyright Reserved Autonics Co., Ltd.
  • Page 28: Read Discrete Input Status(Func 02)

    2. In case of 100037 (0024) DI-10 S8DI-4 input 0:OFF, 1:ON Digital Input10 Edge: 100038 (0025) DI-11 S8DI-5 input 0:OFF, 1:ON Digital Input11 When DI input 100039 (0026) DI-12 S8DI-6 input 0:OFF, 1:ON Digital Input12 © Copyright Reserved Autonics Co., Ltd.
  • Page 29 ALARM KRN-A T6 Slot8 100068 (0043) 0:OFF, 1:ON Slot8 installation TYPE KRN-A T6 Slot9 100069 (0044) KRN- 0:OFF, 1:ON Slot9 installation KRN-A T6 Slot10 100070 (0045) 0:OFF, 1:ON Slot10 installation 100071 to Reserved 100100 © Copyright Reserved Autonics Co., Ltd.
  • Page 30: Read Input Register(Func 04)

    CH2 Unit S1AI-2(CH2) display unit ℃ address. CH2 Range 0:0, 1:0.0, 2:0.00, Set decimal 300214 (00D5) S1AI-2(CH2) range point Point 3:0.000, 4:0.0000 point of PV S2AI-1(CH3) PV(display ※ 2 300215 (00D6) CH3 PV value) © Copyright Reserved Autonics Co., Ltd.
  • Page 31 CH11 Unit ℃ unit address. CH11 Range S6AI-1(CH11) range 0:0, 1:0.0, 2:0.00, Set decimal 300250 (00F9) Point point 3:0.000, 4:0.0000 point of PV 300251 (00FA) S6AI-2(CH12) CH12 Unit ※ 2 PV(display value) 300252 (00FB) © Copyright Reserved Autonics Co., Ltd.
  • Page 32 Higher value than measurement range of the sensor or range: -210000000(HHHH)  Lower value than measurement range of the sensor or range: -220000000(LLLL)  Setting as unknown sensor type: -230000000(ERR)  Non-installed module for the channel: -240000000(NONE)  Higher than input specification: -250000000(BURN)  © Copyright Reserved Autonics Co., Ltd.
  • Page 33 °C User0 ㎃ °F User1 °K mass% μV kg/cm User2 Kcal/m Vol% User3 Kcal Ω User4 mΩ User5 μΩ User6 Blank N/mm User7 μs User8 User9 cd/m Torr mmHg mmAq barrel kVar MVar Blank © Copyright Reserved Autonics Co., Ltd.
  • Page 34: Read Holding Register(Func 03) / Preset Single Register(Func 06) / Preset Multiple Registers(Func 16)

    CH1 special function Analog input:0:Linear, None Function 1:Root, 2:Square, 3:Two Unit If 100 is set, it is Two Unit conversion 400018 (0011) 03/06/16 R/W Two Unit 1 to 35 Digit 3 recognized as value 1.00. © Copyright Reserved Autonics Co., Ltd.
  • Page 35 Set value Input type Set value Input type TC-B PT100 TC-C DPT100 TC-E DPT50 TC-G CU100 TC-J CU50 TC-K ±60mV TC-L ±200mV TC-L(Russia) ±2V TC-N 1to5V TC-P ±5V TC-R -1to10V TC-S 0to20mA TC-T 4to20mA TC-U © Copyright Reserved Autonics Co., Ltd.
  • Page 36 In case of temperature sensor (thermocouple, RTD), you can set Low Graph Scale, High Graph Scale. In case of TC/RTD, fixed 1 decimal point: If 1310℃ is set, input 13100. In case of ±60mV, fixed 2 decimal points: If 30.5mV is set, input 3050. © Copyright Reserved Autonics Co., Ltd.
  • Page 37 CH2 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multi If 1000 is set, it 400071 (0046) 03/06/16 R/W CH2 Span CH2 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 38 CH2 the number of 400074 (0049) 03/06/16 R/W CH2 Filter 1 to 128 digital filter CH2 Burnout CH2 display setting for 0:OFF, 1:UP_SCALE, 400075 (004A) 03/06/16 R/W Action break 2:DOWN_SCALE 400076 to 03/06/16 R/W Reserved 400100 © Copyright Reserved Autonics Co., Ltd.
  • Page 39 03/06/16 R/W CH3 Input Bias CH3 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multipl If 1000 is set, it 400121(0078) 03/06/16 R/W CH3 Span CH3 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 40 CH3 the number of Numb 400124(007B) 03/06/16 R/W CH3 Filter 1 to 128 digital filter CH3 Burnout CH3 display setting for 0:OFF, 1:UP_SCALE, 400125(007C) 03/06/16 R/W Action break 2:DOWN_SCALE 400126 to 03/06/16 R/W Reserved 400150 © Copyright Reserved Autonics Co., Ltd.
  • Page 41 CH4 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multipl If 1000 is set, it 400171 (00AA) 03/06/16 R/W CH4 Span CH4 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 42 CH4 the number of Numb 400174 (00AD) 03/06/16 R/W CH4 Filter 1 to 128 digital filter CH4 Burnout CH4 display setting for 0:OFF, 1:UP_SCALE, 400175 (00AE) 03/06/16 R/W Action break 2:DOWN_SCALE 400176 to 03/06/16 R/W Reserved 400200 © Copyright Reserved Autonics Co., Ltd.
  • Page 43 CH5 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multipl If 1000 is set, it 400221 (00DC) 03/06/16 R/W CH5 Span CH5 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 44 CH5 the number of Numb 400224 (00DF) 03/06/16 R/W CH5 Filter 1 to 128 digital filter CH5 Burnout CH5 display setting for 0:OFF, 1:UP_SCALE, 400225 (00E0) 03/06/16 R/W Action break 2:DOWN_SCALE 400226 to 03/06/16 R/W Reserved 400250 © Copyright Reserved Autonics Co., Ltd.
  • Page 45 CH6 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multipl If 1000 is set, it 400271 (010E) 03/06/16 R/W CH6 Span CH6 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 46 CH6 the number of Numb 400274 (0111) 03/06/16 R/W CH6 Filter 1 to 128 digital filter CH6 Burnout CH6 display setting for 0:OFF, 1:UP_SCALE, 400275 (0112) 03/06/16 R/W Action break 2:DOWN_SCALE 400276 to 03/06/16 R/W Reserved 400300 © Copyright Reserved Autonics Co., Ltd.
  • Page 47 03/06/16 R/W CH7 Input Bias CH7 error correction -9999 to 9999 Digit 0000 applies scale decimal point. 400321 (0140) 03/06/16 R/W CH7 Span CH7 gradient adjustment 0.100 to 5.000 Times 1.000 If 1000 is set, it © Copyright Reserved Autonics Co., Ltd.
  • Page 48 CH7 the number of Numb 400324 (0143) 03/06/16 R/W CH7 Filter 1 to 128 digital filter CH7 Burnout CH7 display setting for 0:OFF, 1:UP_SCALE, 400325 (0144) 03/06/16 R/W Action break 2:DOWN_SCALE 400326 to 03/06/16 R/W Reserved 400350 © Copyright Reserved Autonics Co., Ltd.
  • Page 49 CH8 error correction -9999 to 9999 Digit 0000 applies scale decimal point. Multipl If 1000 is set, it 400371 (0172) 03/06/16 R/W CH8 Span CH8 gradient adjustment 0.100 to 5.000 1.000 is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 50 CH8 the number of Numb 400374 (0175) 03/06/16 R/W CH8 Filter 1 to 128 digital filter CH8 Burnout CH8 display setting for 0:OFF, 1:UP_SCALE, 400375 (0176) 03/06/16 R/W Action break 2:DOWN_SCALE 400376 to 03/06/16 R/W Reserved 400400 © Copyright Reserved Autonics Co., Ltd.
  • Page 51 03/06/16 R/W CH9 Input Bias CH9 error correction -9999 to 9999 Digit 0000 applies scale decimal point. 400421 (01A4) 03/06/16 R/W CH9 Span CH9 gradient adjustment 0.100 to 5.000 Multipl 1.000 If 1000 is set, it © Copyright Reserved Autonics Co., Ltd.
  • Page 52 CH9 the number of Numb 400424 (01A7) 03/06/16 R/W CH9 Filter 1 to 128 digital filter CH9 Burnout CH9 display setting for 0:OFF, 1:UP_SCALE, 400425 (01A8) 03/06/16 R/W Action break 2:DOWN_SCALE 400426 to 03/06/16 R/W Reserved 400450 © Copyright Reserved Autonics Co., Ltd.
  • Page 53 03/06/16 R/W CH10 Input Bias CH10 error correction -9999 to 9999 Digit 0000 applies scale decimal point. CH10 gradient Multipl If 1000 is set, it 400471 (01D6) 03/06/16 R/W CH10 Span 0.100 to 5.000 1.000 adjustment is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 54 CH10 the number of Numb 400474 (01D9) 03/06/16 R/W CH10 Filter 1 to 128 digital filter CH10 Burnout CH10 display setting for 0:OFF, 1:UP_SCALE, 400475 (01DA) 03/06/16 R/W Action break 2:DOWN_SCALE 400476 to 03/06/16 R/W Reserved 400500 © Copyright Reserved Autonics Co., Ltd.
  • Page 55 03/06/16 R/W CH11 Input Bias CH11 error correction -9999 to 9999 Digit 0000 applies scale decimal point. CH11 gradient Multipl If 1000 is set, it 400521 (0208) 03/06/16 R/W CH11 Span 0.100 to 5.000 1.000 adjustment is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 56 CH11 the number of Numb 400524 (020B) 03/06/16 R/W CH11 Filter 1 to 128 digital filter CH11 Burnout CH11 display setting for 0:OFF, 1:UP_SCALE, 400525 (020C) 03/06/16 R/W Action break 2:DOWN_SCALE 400526 to 03/06/16 R/W Reserved 400550 © Copyright Reserved Autonics Co., Ltd.
  • Page 57 03/06/16 R/W CH12 Input Bias CH12 error correction -9999 to 9999 Digit 0000 applies scale decimal point. CH12 gradient Multipl If 1000 is set, it 400571 (023A) 03/06/16 R/W CH12 Span 0.100 to 5.000 1.000 adjustment is recognized as © Copyright Reserved Autonics Co., Ltd.
  • Page 58 CH12 the number of Numb 400574 (023D) 03/06/16 R/W CH12 Filter 1 to 128 digital filter CH12 Burnout CH12 display setting for 0:OFF, 1:UP_SCALE, 400575 (023E) 03/06/16 R/W Action break 2:DOWN_SCALE 400576 to 03/06/16 R/W Reserved 400600 © Copyright Reserved Autonics Co., Ltd.
  • Page 59: Alarm Setup(Alarm Setting)

    Alarm 4 output OFF 400636 (027B) 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400637 (027C) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number © Copyright Reserved Autonics Co., Ltd.
  • Page 60 3 Modbus Mapping Table No(Address) Func R/W Parameter Description Set range Unit Default Note 400638 to 03/06/16 R/W Reserved 400650 ※8. Channel reference table Set value Channel Set value Channel None CH10 CH11 CH12 © Copyright Reserved Autonics Co., Ltd.
  • Page 61 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400687 (02AE) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400688 to 03/06/16 R/W Reserved 400700 © Copyright Reserved Autonics Co., Ltd.
  • Page 62 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm 400737 (02E0) 03/06/16 R/W Alarm4 Alarm No ※ 8 None Refer to channel table. number 400738 to 03/06/16 R/W Reserved 400750 © Copyright Reserved Autonics Co., Ltd.
  • Page 63 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400787 (0312) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400788 to 03/06/16 R/W Reserved 400800 © Copyright Reserved Autonics Co., Ltd.
  • Page 64 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400837 (0344) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400838 to 03/06/16 R/W Reserved 400850 © Copyright Reserved Autonics Co., Ltd.
  • Page 65 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400887 (0376) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400888 to 03/06/16 R/W Reserved 400900 © Copyright Reserved Autonics Co., Ltd.
  • Page 66 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400937 (03A8) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400938 to 03/06/16 R/W Reserved 400950 © Copyright Reserved Autonics Co., Ltd.
  • Page 67 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 400987 (03DA) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 400988 to 03/06/16 R/W Reserved 401000 © Copyright Reserved Autonics Co., Ltd.
  • Page 68 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 401037 (040C) 03/06/16 R/W Alarm4 Alarm No Refer to channel table. None number 401038 to 03/06/16 R/W Reserved 401050 © Copyright Reserved Autonics Co., Ltd.
  • Page 69 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 401087 (043E) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 401088 to 03/06/16 R/W Reserved 401100 © Copyright Reserved Autonics Co., Ltd.
  • Page 70 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 7 401137 (0470) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 401138 to 03/06/16 R/W Reserved 401150 © Copyright Reserved Autonics Co., Ltd.
  • Page 71 03/06/16 R/W Alarm4 OFF Delay 0 to 3600 Sec. 0 delay time Alarm 4 output alarm ※ 8 401187 (04A2) 03/06/16 R/W Alarm4 Alarm No None Refer to channel table. number 401188 to 03/06/16 R/W Reserved 401200 © Copyright Reserved Autonics Co., Ltd.
  • Page 72 03/06/16 R/W S10-AL5 Status AL5 output method 0:NO, 1:NC 401224 (04C7) 03/06/16 R/W S10-AL6 Status AL6 output method 0:NO, 1:NC 401225 to 03/06/16 R/W Reserved 401250 ※9. NO is abbreviation of normally open. NC is abbreviation of normal closed. © Copyright Reserved Autonics Co., Ltd.
  • Page 73: Digital Input Setup(Digital Input Setting)

    03/06/16 R/W Reserved 401300 ※10. Alarm output number table Channel Channel None S8AO-6 S9AO-1 S7AO-1 S9AO-2 S7AO-2 S9AO-3 S7AO-3 S9AO-4 S7AO-4 S9AO-5 S7AO-5 S9AO-6 S7AO-6 S10AO-1 S8AO-1 S10AO-2 S8AO-2 S10AO-3 S8AO-3 S10AO-4 S8AO-4 S10AO-5 S8AO-5 S10AO-6 © Copyright Reserved Autonics Co., Ltd.
  • Page 74 03/06/16 R/W DI-6 Reset No DI-6 reset alarm number Refer to the table. ※ 10 None 401318 (0525) 03/06/16 R/W DI-6 Status DI-6 operation status 0:Edge, 1:Level Edge 401319 to 03/06/16 R/W Reserved 401350 © Copyright Reserved Autonics Co., Ltd.
  • Page 75 None 401367 (0556) 03/06/16 R/W DI-6 Reset No DI-6 reset alarm number Refer to the table. 401368 (0557) 03/06/16 R/W DI-6 Status DI-6 operation status 0:Edge, 1:Level Edge 401369 to 03/06/16 R/W Reserved 401400 © Copyright Reserved Autonics Co., Ltd.
  • Page 76 401417 (0588) 03/06/16 R/W DI-6 Reset No DI-6 reset alarm number Refer to the table. None 401418 (0589) 03/06/16 R/W DI-6 Status DI-6 operation status 0:Edge, 1:Level Edge 401419 to 03/06/16 R/W Reserved 401450 © Copyright Reserved Autonics Co., Ltd.
  • Page 77: Communication Setup(Communication Setting)

    USB Device Port Use USB communication 0:Disable, 1:Enable Enable Device USB Device USB communication 401537 (0600) 0:Disable, 1:Enable Enable Device Com Write write 401538 to Reserved 401550 ※Communication setting is only available to read. © Copyright Reserved Autonics Co., Ltd.
  • Page 78: Record Setup

    0:10, 1:20, 2:40, 3:60, standard record 401560 (0617) 03/06/16 R/W Alarm Speed Alarm record speed mm/h 20 4:120, 5:240 speed, option and alarm record speed is also changed as same value. Option and alarm record © Copyright Reserved Autonics Co., Ltd.
  • Page 79 03/06/16 R/W Start Line Print 0:OFF, 1:ON record 0: Disable, 1:1hour, Range Print Input range record 2:2hour, 3:3hour, 401567 (061E) 03/06/16 R/W Hour Disable Time period 4:4hour, 5:5hour, 6:6hour to 24:24hour 401568 to 03/06/16 R/W Reserved 401600 © Copyright Reserved Autonics Co., Ltd.
  • Page 80: System Setup(System Setting)

    1 to 3600 0:OFF, 1:Min, 401639 (0666) 03/06/16 R/W Backlight LCD backlight brightness Standard 2:Standard, 3:Max Backlight LCD backlight ON 401640 (0667) 03/06/16 R/W 0:Temp, 1: Always min. Temp On/Off method 401641 to 03/06/16 Reserved 401650 © Copyright Reserved Autonics Co., Ltd.
  • Page 81: File/Memory Setup(File/Memory Setting)

    401707 to 03/06/16 R/W Reserved 401750 ※ If changing general user to administrator by communication, KRN100 is also changed as administrator authority. Or by KRN100 front key, it operates as administrator authority from Modbus communication. © Copyright Reserved Autonics Co., Ltd.

Table of Contents